Post by timvh on Remote connection to ifm PLC & HMI
CODESYS Forge
talk
(Post)
Maybe also good to know that you could use the CODESYS installer to switch between gateways. - open the CODESYS installer - Select the (hamburger) menu - Select Settings - Select Services Then select the Gateway you would like to use.
Last updated: 2024-04-23
Post by valenting on Problem with Licenced Software Metrics
CODESYS Forge
talk
(Post)
Update: it seems that the license is detected by CODESYS on my computer but not detected by the runtime on my device. I'm using Codesys control for raspberry pi in the latest version 4.11.0.0 Is there something to do to correct this ?
Last updated: 2024-04-29
Post by arrotek on Codesys HMI Redundancy
CODESYS Forge
talk
(Post)
Is there a way to run Codesys HMI on two different PC's and have the web visu clients fail over to the HMI instance that is wokring or running?
Last updated: 2024-05-30
Post by eschwellinger on Licensing info not available (WAGO PFC200 + Codesys V3)
CODESYS Forge
talk
(Post)
Seems that the Wago Target does not support the licensing. Either use PFC200 SL from CODESYS Store or ask the Wago support for help.
Last updated: 2024-06-10
Post by fajean on CODESYS control on RPi starts, shortly runs, then exits
CODESYS Forge
talk
(Post)
https://us.store.codesys.com/codesys-control-for-raspberry-pi-sl.html Quoted from the "additional requirements" section : The operating system Raspberry Pi OS (32-bit)
Last updated: 2024-06-14
Post by kthomas on Cant login to Rpi4 but can see it in codesys communications settings.
CODESYS Forge
talk
(Post)
This is what I see in codesys window. And here is with the netstat command on the pi
Last updated: 2024-06-23
Post by eschwellinger on License Reset Request – CODESYS Control Win V3 Standard L
CODESYS Forge
talk
(Post)
Please write these kind of request to 'my question' in the CODESYS Store. please do not use ticket and softcontainer numbers here.
Last updated: 2025-10-23
Post by eschwellinger on search runtime 4.9.0.0 for pi 3
CODESYS Forge
talk
(Post)
sorry I missed to say how to do this just update the runtime. (extract latest debian package out of the CODESYS package) but 8n this case an update all to the latest version including CODESYS is probably the easiest option now.
Last updated: 2025-10-26
Post by nano on conformation about the CODESYS Extends SL and CODESYS SDK
CODESYS Forge
talk
(Post)
as an oem i can tell you, extension sl isn't the sdk. its more an hard restricted part of it with much missing parts. why u may ask this?
Last updated: 2025-11-11
Post by shaunvdm on OSCAT Scale_r function not working in LD 4.60 works in LAD2 on 3.5.21sp3
CODESYS Forge
talk
(Post)
Hi All, We downgraded Codesys LAD/FB in the IDE to version 4.5 and it works. Codesys Version 4.6 lad/fb not working. Was the way we fixed this. Kind Regards Shaun
Last updated: 2025-11-17
SoftPLC (CODESYS Control x86 RTE V3 x64) OPC UA binds only to 127.0.0.1 — Not binding to LAN IP
CODESYS Forge
talk
(Thread)
SoftPLC (CODESYS Control x86 RTE V3 x64) OPC UA binds only to 127.0.0.1 — Not binding to LAN IP
Last updated: 2025-11-24
Post by timvh on Error: C0138: No matching 'FB_Init' method found for instantiation of VisuClientObjectMgr
CODESYS Forge
talk
(Post)
Maybe check: - The library manager, are you maybe missing some libraries - Tools - CODESYS installer: update the CODESYS Visualization and Visualization support - Project - Project environment: maybe you need to update the visualization profile
Last updated: 2025-11-27
Post by gseidel on STEPPER CODESYS SOFTMOTION_DRIVE
CODESYS Forge
talk
(Post)
Hi kalmeyer, I would recommend to have a look at these examples. They come with a project and a description: https://content.helpme-codesys.com/en/CODESYS%20SoftMotion/_sm_basic_examples_single_axis.html. Best regards, Georg
Last updated: 2025-11-28
Post by sb879 on Non-formal invocation of function blocks in CODESYS
CODESYS Forge
talk
(Post)
Is it possible to do non-formal invocation of function blocks in CODESYS? I get an error when I try, see the attached pic. Also attached a pic from IEC 61131-3 describing non-formal invocations.
Last updated: 2025-12-04
Post by sb879 on Non-formal invocation of function blocks in CODESYS
CODESYS Forge
talk
(Post)
Is it possible to do non-formal invocation of function blocks in CODESYS? I get an error when I try, see the attached pic. Also attached a pic from IEC 61131-3 describing non-formal invocations.
Last updated: 2025-12-04
Post by bruno-roth on Parker Compax3 controlled by Schneider LMC 201
CODESYS Forge
talk
(Post)
Hello, you could use any CODESYS PLC which has an EtherCAT master and the possibility to run the CODESYS Softmotion.
Last updated: 2026-01-13
Transparent wireless serial bridge for Modbus RTU – experience with LoRa/WiFi RS-485 link to CODESYS runtime
CODESYS Forge
talk
(Thread)
Transparent wireless serial bridge for Modbus RTU – experience with LoRa/WiFi RS-485 link to CODESYS runtime
Last updated: 2026-03-18
Post by totorovic on Ladder editor bug with 3.5.21.20
CODESYS Forge
talk
(Post)
Hello, With Codesys 3.5.21.10 the ladder editor displays : With Codesys 3.5.17.21, the same code was correctly displayed : The compilation is error free Please check image attached
Last updated: 2026-05-07
Post by caualima on AI + Programming
CODESYS Forge
talk
(Post)
What do you think about having an AI Agent specialized in ST programming in Codesys? I see this saving hours and hours of work for those who program on a daily basis.
Last updated: 2026-01-24
Post by yoeri on Python script: Launch Codesys, Execute Script, Exit Codesys
CODESYS Forge
talk
(Post)
For whoever finds this old thread. Instead of System.exit(0), use system.exit(0) without capital 'S', this worked for me. I use these imports from future import print_function import sys import os
Last updated: 2026-02-12
Post by george32 on CSV file and string manipulation.
CODESYS Forge
talk
(Post)
Dear folks, I think I have a rather simple question but I could not find the right answer to my question: I have made with Excel a CSV file where I would like to have some general data regarding my program variables. I have made an program what let me read the file. The string I am currently get is at follows: 'IP_Adres;192.168.45.12$R$NPort_number;2000$R$NCycle_time;43$R$NStart_Standard_IO;20$R$N' Now I want to split the string in multiple part, which I later would connect to the right variable. By Google and experimenting I have reached to the following code for the first part of the splitting proces: // Splitting the BOM of the string: Received_string := FileReadString; IF LEFT(STR:=New_string,3)= '' THEN Received_string_without_BOM :=RIGHT(STR:= Received_string,SIZE:= (LEN(STR:= Received_string))-3); END_IF //Splitting the remaining string in part for later declaration. WHILE index = 0 DO index_split_part := FIND(STR1:= Received_string_without_BOM,STR2:= '$R$N'); Part_of_String[index]:=LEFT(STR:=Received_string_without_BOM, SIZE:= index_split_part); index := index + 1; END_WHILE However in the splitting proces I could not understand what is really happening. I understand that the Find() function returns the first value the $R$N in the Received_string_without_BOM. This would mean that the index_split_part := 23 I|P| _ |A |d|r|e|s|;|1_|9 |2 |. |1 |6 |8 |. |4 |5 |. |1 |2 |$ |R |$ |N |P | 1|2| 3 |4 |5|6|7|0|9|10|11|12|13|14|15|16|17|18|19|20|21|22|23|24|25|26|27| So the next part is to read the first 23 characters of the Received_string_without_BOM with the LEFT() function. I expected that the outcome the following was: 'IP_Adres;192.168.45.12$'. However the outcome is: 'IP_Adres;192.168.45.12$R'. I do not understand where the R after the $ sign comes from, because its place is 24 so it would not be added to the part_of the_string[index]. If I hard coded value 24 for the size it gives me the following return: 'IP_Adres;192.168.45.12$R$N'. I would expect everything till the R but the code adds the $N also to the string. I hope someone could explain to my what I am seeing wrong in my point of view? With kind regards, George
Last updated: 2024-09-27
Post by rcaponi on Codesys 3.5 SP19 Patch 4. Trace context menu does not work
CODESYS Forge
talk
(Post)
Hello, I'm using the new Codesys 3.5 SP19 Patch 4 version with CODESYS Control for Raspberry Pi MC SL v4.8. Compared to the Codesys 3.5 SP19 Patch 1 version, the context menu on a Trace object no longer works. So I can no longer run the Downloader Trace command. Do any options need to be enabled with the new version? Best regards Roberto Caponi
Last updated: 2023-10-24
Post by narius on OPC-UA object instances preexisting in imported xml information model
CODESYS Forge
talk
(Post)
Hi all, is it possible to use object instances that are not instantiated by codesys itself, e.g. have been defined in UA-Modeler ? When I browse the plc with UA-Expert I see those instances, but I have not seen information in codesys or the web if these are writable in codesys. So far, I am under the impression, that it is not possible, but would like to hear from others. Also, is it correct, that it is not possible to create references inside codesys ? Thanks in advance and kr
Last updated: 2024-08-08
Post by spilin on All devices lost for all installed version
CODESYS Forge
talk
(Post)
hello. After installing the latest version of codesys (3.5.20) from codesys installer, I had a problem. All my devices disappeared. Both PLCs and IO modules and network devices disappeared from my list. I browsed through the Windows files and I can find them in the programdata/codesys/devices folder. The files remain there, but they are not available within codesys (same error in all installed versions) which in this case are 3.5.16 and 3.5.19. Does anyone know how I can reimport or resynchronize my devices folder again? Thanks
Last updated: 2024-09-11
Post by dkugler on csv datei einlesen und verarbeiten
CODESYS Forge
talk
(Post)
in der https://store.codesys.com/de/codesys-iiot-libraries-sl.html ist u.a. die CSV Utility SL Bibliothek incl. Beispiel enthalten. Die kostet etwas. Generell Codesys Beispiele findest Du hier: https://content.helpme-codesys.com/de/CODESYS%20Examples/_ex_start_page.html Alternativ file read verwenden und Zeit investieren um von Hand zu Fuß den Dateiinhalt zu durchforsten: https://content.helpme-codesys.com/de/CODESYS%20Examples/_ex_cds_file_utilities.html In der OSCAT Library gab es mal noch etwas, da könnte google weiterhelfen