<?xml version="1.0" encoding="utf-8"?>
<feed xml:lang="en" xmlns="http://www.w3.org/2005/Atom"><title>Activity for anlebr</title><link href="https://forge.codesys.com/u/anlebr/activity/" rel="alternate"/><id>https://forge.codesys.com/u/anlebr/activity/</id><updated>2025-04-01T20:46:03.274000Z</updated><subtitle>Recent activity for anlebr</subtitle><entry><title>anlebr posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/8edacbe55b/?limit=25#55b5" rel="alternate"/><published>2025-04-01T20:46:03.274000Z</published><updated>2025-04-01T20:46:03.274000Z</updated><author><name>anlebr</name><uri>https://forge.codesys.com/u/anlebr/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/8edacbe55b/?limit=25#55b5</id><summary type="html">Hi In the POU section of my project I have created a Fan function block and defined an alarm group template for this FB with one alarm (Motor fault). In the PLC program I define two instances of the fan function block. When going to the alarm configuration and pressing "Create or update alarm instances", I get two alarms listed. So far so good. However, when I start my program and check the alarm table in the visualization I only see one alarm, even if both are active. Am I doing something wrong,...</summary></entry><entry><title>anlebr posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/9fdfff1da6/?limit=25#648d" rel="alternate"/><published>2024-09-18T19:34:04.758000Z</published><updated>2024-09-18T19:34:04.758000Z</updated><author><name>anlebr</name><uri>https://forge.codesys.com/u/anlebr/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/9fdfff1da6/?limit=25#648d</id><summary type="html">Hi I posted the same question at Wago Community. PatrickR told me to use an older version of the nodesets. I dont remember exactly what I did, but I am quite sure this somehow led to a solution. Hope this helps :)</summary></entry><entry><title>anlebr posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/9fdfff1da6/?limit=25#63e2" rel="alternate"/><published>2024-03-13T16:30:38.560000Z</published><updated>2024-03-13T16:30:38.560000Z</updated><author><name>anlebr</name><uri>https://forge.codesys.com/u/anlebr/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/9fdfff1da6/?limit=25#63e2</id><summary type="html">Hi I am trying use the Codesys Communication Manager to set up an Opc ua server with a custom information model. As a start I am using the Boiler model available on Opc foundations github page. I am testing with a Wago CC100 and using Codesys V3.5 SP19 Patch 6. I get the following error: Communication Manager [Device: PLC Logic: Application]: The information model http://opcfoundation.org/UA/ is required by http://opcfoundation.org/UA/Boiler/ with a minimal publication date from 15/12/2023 but the...</summary></entry></feed>