<?xml version="1.0" encoding="utf-8"?>
<feed xml:lang="en" xmlns="http://www.w3.org/2005/Atom"><title>Activity for bingo</title><link href="https://forge.codesys.com/u/bingo/activity/" rel="alternate"/><id>https://forge.codesys.com/u/bingo/activity/</id><updated>2025-03-03T10:24:44.657000Z</updated><subtitle>Recent activity for bingo</subtitle><entry><title>bingo posted a comment on discussion Forge 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/forge/thread/715b2f1c3c/?limit=25#abb2" rel="alternate"/><published>2025-03-03T10:24:44.657000Z</published><updated>2025-03-03T10:24:44.657000Z</updated><author><name>bingo</name><uri>https://forge.codesys.com/u/bingo/profile/</uri></author><id>https://forge.codesys.com/forge/talk/forge/thread/715b2f1c3c/?limit=25#abb2</id><summary type="html">Suppose you need to switch PLC IP dynamically between 192.168.1.10\192.168.2.10, First, set PLC IP to 192.16.1.10. Create a PGVL with a flag ‘xUseSecondry’ xUseSecondry : bool ; create a function that use socket to update IP: FUNCTION fSwitchIP : bool VAR_INPUT useMainIP:bool; END_VAR --------------------------------CODE------ if useMainIP then SysSockSetIPAddress(‘0’, ‘192.168.1.10’); PGVL.xUseSecondry := 0; else SysSockSetIPAddress(‘0’, ‘192.168.2.10’); PGVL.xUseSecondry := 1; end_if Now, if during...</summary></entry><entry><title>bingo posted a comment on discussion Forge 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/forge/thread/715b2f1c3c/?limit=25#2b2c" rel="alternate"/><published>2025-03-02T13:35:17.549000Z</published><updated>2025-03-02T13:35:17.549000Z</updated><author><name>bingo</name><uri>https://forge.codesys.com/u/bingo/profile/</uri></author><id>https://forge.codesys.com/forge/talk/forge/thread/715b2f1c3c/?limit=25#2b2c</id><summary type="html">For a permanent change, you may need to update the PLC configuration file or set the IP at startup using retained variables.</summary></entry><entry><title>bingo posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/7f12b2aab9/?limit=25#b1e3" rel="alternate"/><published>2023-03-29T09:30:46.457000Z</published><updated>2023-03-29T09:30:46.457000Z</updated><author><name>bingo</name><uri>https://forge.codesys.com/u/bingo/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/7f12b2aab9/?limit=25#b1e3</id><summary type="html">I have an application stored at PlsPrg, it is not a boot application. the RTE is running, there is no application shown in the RTE info. I would like to run the application. Is it possible to do it via PLC command line?</summary></entry></feed>