<?xml version="1.0" encoding="utf-8"?>
<feed xml:lang="en" xmlns="http://www.w3.org/2005/Atom"><title>Activity for cfam</title><link href="https://forge.codesys.com/u/cfam/activity/" rel="alternate"/><id>https://forge.codesys.com/u/cfam/activity/</id><updated>2024-08-12T15:00:03.363000Z</updated><subtitle>Recent activity for cfam</subtitle><entry><title>cfam posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/0c6e49e1cc/?limit=25#38cb" rel="alternate"/><published>2024-08-12T15:00:03.363000Z</published><updated>2024-08-12T15:00:03.363000Z</updated><author><name>cfam</name><uri>https://forge.codesys.com/u/cfam/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/0c6e49e1cc/?limit=25#38cb</id><summary type="html">Good day I would appreciate it if you can give me some advice on how to fix my "Bus Not Running Error". I am Using Codesys 3.5 SP20 and Codesys Control PLCnext SL V4.12.0.0. Codesys control was installed on the device and I can log into it but it seems that it does not pick up the PLC or the IO attached (Please see attached Image). The Bus Cycle Task of the AXL F 2152 is set to Main Task and the "Always update Variable" is Enabled on each IO Module. My Main Task interval is set to 100ms and Priority...</summary></entry><entry><title>cfam posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/649ad6a9f2/?limit=25#fb69" rel="alternate"/><published>2024-08-12T14:59:59.341000Z</published><updated>2024-08-12T14:59:59.341000Z</updated><author><name>cfam</name><uri>https://forge.codesys.com/u/cfam/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/649ad6a9f2/?limit=25#fb69</id><summary type="html">Good day I would appreciate it if you can give me some advice on how to fix my "Bus Not Running Error". I am Using Codesys 3.5 SP20 and Codesys Control PLCnext SL V4.12.0.0. Codesys control was installed on the device and I can log into it but it seems that it does not pick up the PLC or the IO attached (Please see attached Image). The Bus Cycle Task of the AXL F 2152 is set to Main Task and the "Always update Variable" is Enabled on each IO Module. My Main Task interval is set to 100ms and Priority...</summary></entry><entry><title>cfam posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/381bcf3e0b/?limit=25#e899" rel="alternate"/><published>2023-12-06T07:51:34.851000Z</published><updated>2023-12-06T07:51:34.851000Z</updated><author><name>cfam</name><uri>https://forge.codesys.com/u/cfam/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/381bcf3e0b/?limit=25#e899</id><summary type="html">Good day All I would like to share some information on this site for the Codesys team as well for the future members using Codesys Control for PLCnext if it is allowed. I hope that i Post it in the correct spot. Subject: Codesys, Codesys Control for PLCnext Objective: Using the following Phoenix components to built a PLC Rack and run it on Codesys: Hardware and Software used 1. 2404267, AXC F 2152 - Controller 2. 1088136, AXL F BP SE6 - Module carrier 3. 1088129, AXL SE DO16/1 - Digital module 4....</summary></entry></feed>