<?xml version="1.0" encoding="utf-8"?>
<feed xml:lang="en" xmlns="http://www.w3.org/2005/Atom"><title>Activity for dsongra</title><link href="https://forge.codesys.com/u/dsongra/activity/" rel="alternate"/><id>https://forge.codesys.com/u/dsongra/activity/</id><updated>2022-06-01T07:27:23.172000Z</updated><subtitle>Recent activity for dsongra</subtitle><entry><title>dsongra posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/c039b3a748/?limit=25#632c" rel="alternate"/><published>2022-06-01T07:27:23.172000Z</published><updated>2022-06-01T07:27:23.172000Z</updated><author><name>dsongra</name><uri>https://forge.codesys.com/u/dsongra/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/c039b3a748/?limit=25#632c</id><summary type="html">Hello, I have Hilscher Make CIFX 50-RE PC card, I want to use this PC into Codesys application to make this PC card as a Profinet IO Controller to communicate with Profinet IO Slave device. Codesys Software version - V3.5 SP15 + (32bit). So Could you please provide me step wise procedure to complete this application. Thanks in advance. Br, Devendra</summary></entry><entry><title>dsongra posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/1a7dfcfcf2/?limit=25#4127" rel="alternate"/><published>2021-03-25T07:10:42.004000Z</published><updated>2021-03-25T07:10:42.004000Z</updated><author><name>dsongra</name><uri>https://forge.codesys.com/u/dsongra/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/1a7dfcfcf2/?limit=25#4127</id><summary type="html">Thanks, I have requested, i will update once issue resolved.</summary></entry><entry><title>dsongra modified a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/1a7dfcfcf2/?limit=25#9a9b" rel="alternate"/><published>2021-03-25T06:03:10.825000Z</published><updated>2021-03-25T06:03:10.825000Z</updated><author><name>dsongra</name><uri>https://forge.codesys.com/u/dsongra/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/1a7dfcfcf2/?limit=25#9a9b</id><summary type="html">Hello, thanks for your reply. I already tried the same. In license folder but not showing this file attached screenshot (file info). can I do factory reset of my netPi module, and reinstall License key. I have not taken backup of license key. Is it possible to reinstall license key on the same hardware? Br, Devendra</summary></entry><entry><title>dsongra posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/1a7dfcfcf2/?limit=25#9a9b" rel="alternate"/><published>2021-03-25T05:56:31.348000Z</published><updated>2021-03-25T05:56:31.348000Z</updated><author><name>dsongra</name><uri>https://forge.codesys.com/u/dsongra/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/1a7dfcfcf2/?limit=25#9a9b</id><summary type="html">Hello, thanks for your reply. I already tried the same. In license folder but not showing this file attached screenshot (file info). can I do factory reset of my netPi module, and reinstall License key. Is it possible to reinstall license key on the same hardware? Br, Devendra</summary></entry><entry><title>dsongra posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/1a7dfcfcf2/?limit=25#2a6d" rel="alternate"/><published>2021-03-25T05:14:15.003000Z</published><updated>2021-03-25T05:14:15.003000Z</updated><author><name>dsongra</name><uri>https://forge.codesys.com/u/dsongra/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/1a7dfcfcf2/?limit=25#2a6d</id><summary type="html">Codesys Docker container I reinstalled in netpi module https://hub.docker.com/r/hilschernetpi/netpi-codesys-basis. after this I check for license in codesys software in that case it is showing nothing.</summary></entry><entry><title>dsongra posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/1a7dfcfcf2/?limit=25#0999" rel="alternate"/><published>2021-03-25T04:45:33.953000Z</published><updated>2021-03-25T04:45:33.953000Z</updated><author><name>dsongra</name><uri>https://forge.codesys.com/u/dsongra/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/1a7dfcfcf2/?limit=25#0999</id><summary type="html">Hello, I have netPI Gateway. same procedure I already did, but after some changes done in netPI Module, now in codesys not showing license details attached screenshot (license info), target device selected already attached screenshot (select device). Br, Devendra</summary></entry><entry><title>dsongra posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/1a7dfcfcf2/?limit=25#ab6d" rel="alternate"/><published>2021-03-24T12:21:37.043000Z</published><updated>2021-03-24T12:21:37.043000Z</updated><author><name>dsongra</name><uri>https://forge.codesys.com/u/dsongra/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/1a7dfcfcf2/?limit=25#ab6d</id><summary type="html">I am waiting for reply, it is little bit urgent to resolved this issue, we Have purchased license key.</summary></entry><entry><title>dsongra posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/1a7dfcfcf2/?limit=25#3204" rel="alternate"/><published>2021-03-23T07:50:06.481000Z</published><updated>2021-03-23T07:50:06.481000Z</updated><author><name>dsongra</name><uri>https://forge.codesys.com/u/dsongra/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/1a7dfcfcf2/?limit=25#3204</id><summary type="html">Hello, I am getting error while installing codesys license in Software. could you please help me. Thanks in advance. Br, Devendra</summary></entry><entry><title>dsongra modified a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/0abaf8ba05/?limit=25#f75c/fbae/3502" rel="alternate"/><published>2020-11-19T04:25:49.494000Z</published><updated>2020-11-19T04:25:49.494000Z</updated><author><name>dsongra</name><uri>https://forge.codesys.com/u/dsongra/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/0abaf8ba05/?limit=25#f75c/fbae/3502</id><summary type="html">Hello, Thank you so much for your support. Now I am getting correct value. please find below screenshot. Br, Devendra</summary></entry><entry><title>dsongra posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/0abaf8ba05/?limit=25#f75c/fbae/3502" rel="alternate"/><published>2020-11-19T04:25:17.086000Z</published><updated>2020-11-19T04:25:17.086000Z</updated><author><name>dsongra</name><uri>https://forge.codesys.com/u/dsongra/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/0abaf8ba05/?limit=25#f75c/fbae/3502</id><summary type="html">Hello, Thank you so much for your support. Now I am getting correct value. please find below screenshot. Br, Devendra</summary></entry><entry><title>dsongra modified a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/0abaf8ba05/?limit=25#f75c" rel="alternate"/><published>2020-11-18T10:45:32.576000Z</published><updated>2020-11-18T10:45:32.576000Z</updated><author><name>dsongra</name><uri>https://forge.codesys.com/u/dsongra/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/0abaf8ba05/?limit=25#f75c</id><summary type="html">Hi, Yes, you are correct. I have tried both logics as above, result same for both. But value is different. Sensor place at 20 cm/0.2 meter distance between an object, received value screenshot attached, result should be like 20 cm/0.2 meter accordingly to the attached screenshot value (Conversion). according to attached conversion info screenshot. Br, Devendra</summary></entry><entry><title>dsongra posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/0abaf8ba05/?limit=25#f75c" rel="alternate"/><published>2020-11-18T08:31:35.270000Z</published><updated>2020-11-18T08:31:35.270000Z</updated><author><name>dsongra</name><uri>https://forge.codesys.com/u/dsongra/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/0abaf8ba05/?limit=25#f75c</id><summary type="html">Hi, Yes, you are correct. I have tried both logics as above, result same for both. But value is different. Sensor place at 20 cm/0.2 meter distance between an object, received value screenshot attached, result should be like 20 cm/0.2 meter accordingly to the attached screenshot value (Conversion). Br, Devendra</summary></entry><entry><title>dsongra modified a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/0abaf8ba05/?limit=25#4567" rel="alternate"/><published>2020-11-11T05:50:35.757000Z</published><updated>2020-11-11T05:50:35.757000Z</updated><author><name>dsongra</name><uri>https://forge.codesys.com/u/dsongra/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/0abaf8ba05/?limit=25#4567</id><summary type="html">Hello, I am working on IOT kit using Hilscher NetIOT Connect Gateway, I have P&amp;F Ultrasonic sensor (range 4000mm), i am getting process data 14 bit in two bytes (attachment Received data). I want to convert it into 16bit uint starting 2 bit offset of first byte, bit read start from bit 2 to bit 14. So value should be in mm. Thanks in advance. Br, Devendra</summary></entry><entry><title>dsongra posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/0abaf8ba05/?limit=25#4567" rel="alternate"/><published>2020-11-11T05:50:14.663000Z</published><updated>2020-11-11T05:50:14.663000Z</updated><author><name>dsongra</name><uri>https://forge.codesys.com/u/dsongra/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/0abaf8ba05/?limit=25#4567</id><summary type="html">Hello, My name is Devendra, I am working on IOT kit using Hilscher NetIOT Connect Gateway, I have P&amp;F Ultrasonic sensor (range 4000mm), i am getting process data 14 bit in two bytes (attachment Received data). I want to convert it into 16bit uint starting 2 bit offset of first byte, bit read start from bit 2 to bit 14. So value should be in mm. Thanks in advance. Br, Devendra</summary></entry><entry><title>dsongra created a blog post</title><link href="https://forge.codesys.com/u/dsongra/blog/2020/11/data-conversion/" rel="alternate"/><published>2020-11-11T05:44:15.963000Z</published><updated>2020-11-11T05:44:15.963000Z</updated><author><name>dsongra</name><uri>https://forge.codesys.com/u/dsongra/profile/</uri></author><id>https://forge.codesys.com/u/dsongra/blog/2020/11/data-conversion/</id><summary type="html">Data conversion</summary></entry></feed>