<?xml version="1.0" encoding="utf-8"?>
<feed xml:lang="en" xmlns="http://www.w3.org/2005/Atom"><title>Activity for fabiodasilveira</title><link href="https://forge.codesys.com/u/fabiodasilveira/activity/" rel="alternate"/><id>https://forge.codesys.com/u/fabiodasilveira/activity/</id><updated>2026-07-27T10:14:30.213000Z</updated><subtitle>Recent activity for fabiodasilveira</subtitle><entry><title>fabiodasilveira posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/634dc4501e/?limit=25#a147" rel="alternate"/><published>2026-07-27T10:14:30.213000Z</published><updated>2026-07-27T10:14:30.213000Z</updated><author><name>fabiodasilveira</name><uri>https://forge.codesys.com/u/fabiodasilveira/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/634dc4501e/?limit=25#a147</id><summary type="html">Hello Everyone, I am really struggling to understand why codesys would present an error regarding the following: VAR strByte1: STRING(10):= '192'; strByte2: STRING(10):= '168'; strByte3: STRING(10):= '1'; strByte4: STRING(10):= '0'; strIPAddress: STRING:= '192.168.1.1'; END_VAR //Updating Variables strByte1:= BYTE_TO_STRING(GVL.abyPSsIpAddress[0]); strByte2:= BYTE_TO_STRING(GVL.abyPSsIpAddress[1]); strByte3:= BYTE_TO_STRING(GVL.abyPSsIpAddress[2]); strByte4:= BYTE_TO_STRING(GVL.abyPSsIpAddress[3]);...</summary></entry><entry><title>fabiodasilveira posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/fa012acc3e/?limit=25#5956" rel="alternate"/><published>2026-06-23T14:06:58.413000Z</published><updated>2026-06-23T14:06:58.413000Z</updated><author><name>fabiodasilveira</name><uri>https://forge.codesys.com/u/fabiodasilveira/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/fa012acc3e/?limit=25#5956</id><summary type="html">It is a shame that it does not work with Eaton XC303 PLCs :(</summary></entry><entry><title>fabiodasilveira posted a comment on discussion Forge 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/forge/thread/715b2f1c3c/?limit=25#b394" rel="alternate"/><published>2025-03-04T14:29:37.141000Z</published><updated>2025-03-04T14:29:37.141000Z</updated><author><name>fabiodasilveira</name><uri>https://forge.codesys.com/u/fabiodasilveira/profile/</uri></author><id>https://forge.codesys.com/forge/talk/forge/thread/715b2f1c3c/?limit=25#b394</id><summary type="html">Thank you, Bingo. Your idea of adding the change to the start up process works. However, I am still intrigued with the fact that SysSockSetIPAddress(strEthernetPort:= '0', strIPAddress:= '192.168.2.12') is different from PLC Shell (setipaddr 0 192.168.2.12).:-(</summary></entry><entry><title>fabiodasilveira posted a comment on discussion Forge 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/forge/thread/715b2f1c3c/?limit=25#1db3" rel="alternate"/><published>2025-03-03T09:20:29.216000Z</published><updated>2025-03-03T09:20:29.216000Z</updated><author><name>fabiodasilveira</name><uri>https://forge.codesys.com/u/fabiodasilveira/profile/</uri></author><id>https://forge.codesys.com/forge/talk/forge/thread/715b2f1c3c/?limit=25#1db3</id><summary type="html">Thank you, Bingo. I have added the instructions below to the CODESYSControl.cfg file, but they haven't changed anything. [SysSocket] Adapter.0.Name="ETH0" Adapter.0.EnableSetIpAndMask=1 Adapter.1.Name="ETH1" Adapter.1.EnableSetIpAndMask=1 Regarding your second suggestion, could you please expand a bit on that?</summary></entry><entry><title>fabiodasilveira modified a comment on discussion Forge 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/forge/thread/715b2f1c3c/?limit=25#c338" rel="alternate"/><published>2025-02-28T08:10:28.586000Z</published><updated>2025-02-28T08:10:28.586000Z</updated><author><name>fabiodasilveira</name><uri>https://forge.codesys.com/u/fabiodasilveira/profile/</uri></author><id>https://forge.codesys.com/forge/talk/forge/thread/715b2f1c3c/?limit=25#c338</id><summary type="html">Hello Everybody, I have created a project for an Eaton XC303 that sends lots of data to a router via UDP. It works fine. However, when there is more than one product connected to the router, then it is necessary to change the IP address of the Ethernet port 0, from e.g. 192.168.2.11 to 192.168.2.12 (second product). It is easily done via PLC Shell (setipaddr 0 192.168.2.12), but the people in production is struggling with the PLC Shell commands and I would like to create a Visualization page that...</summary></entry><entry><title>fabiodasilveira posted a comment on discussion Forge 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/forge/thread/715b2f1c3c/?limit=25#c338" rel="alternate"/><published>2025-02-27T16:19:18.081000Z</published><updated>2025-02-27T16:19:18.081000Z</updated><author><name>fabiodasilveira</name><uri>https://forge.codesys.com/u/fabiodasilveira/profile/</uri></author><id>https://forge.codesys.com/forge/talk/forge/thread/715b2f1c3c/?limit=25#c338</id><summary type="html">Hello Everybody, I have created a project for an Eaton XC303 that sends lots of data to a router via UDP. It works fine. However, when there is more than one product connected to the router, then it is necessary to change the IP address of the Ethernet port 0, from e.g. 192.168.2.11 to 192.168.2.12 (second product). It is easily done via PLC Shell (setipaddr 0 192.168.2.12), but the people in production is struggling with the PLC Shell commands and I would like to create a Visualization page that...</summary></entry><entry><title>fabiodasilveira posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/cb2cc5fde3/?limit=25#20fa/9032" rel="alternate"/><published>2021-11-03T11:46:43.706000Z</published><updated>2021-11-03T11:46:43.706000Z</updated><author><name>fabiodasilveira</name><uri>https://forge.codesys.com/u/fabiodasilveira/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/cb2cc5fde3/?limit=25#20fa/9032</id><summary type="html">Thank you for your suggestions Tim, (timvh)! The software is now working.</summary></entry><entry><title>fabiodasilveira posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/cb2cc5fde3/?limit=25#eca9" rel="alternate"/><published>2021-08-31T15:32:41.516000Z</published><updated>2021-08-31T15:32:41.516000Z</updated><author><name>fabiodasilveira</name><uri>https://forge.codesys.com/u/fabiodasilveira/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/cb2cc5fde3/?limit=25#eca9</id><summary type="html">Dear Members, I wonder if someone already managed to create a FB that emulates the Modbus Slave COM Port that is normally added to the Device Tree. I need to do that via a FB, because I do not know how many slaves will be added. That information will be provided on site during the installation of the equipment, e.g via the visualization - 2 slaves, 3 slaves, .. 30 slaves. I have created a FB that EXTENDS ModbusSlaveComPort, which is the same type of object that is added to the device tree. However,...</summary></entry></feed>