<?xml version="1.0" encoding="utf-8"?>
<feed xml:lang="en" xmlns="http://www.w3.org/2005/Atom"><title>Activity for fjcano</title><link href="https://forge.codesys.com/u/fjcano/activity/" rel="alternate"/><id>https://forge.codesys.com/u/fjcano/activity/</id><updated>2022-02-22T12:51:25.624000Z</updated><subtitle>Recent activity for fjcano</subtitle><entry><title>fjcano posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/bd95b9d6d2/?limit=25#7e04" rel="alternate"/><published>2022-02-22T12:51:25.624000Z</published><updated>2022-02-22T12:51:25.624000Z</updated><author><name>fjcano</name><uri>https://forge.codesys.com/u/fjcano/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/bd95b9d6d2/?limit=25#7e04</id><summary type="html">Hello, I want to limit ModbusTCP Slave Device Input Register to zero. Reading the device documentation i have seen it is possible at the "device description". Not sure which this reference applied to. Another question i want to ask, if it is possible to modify the modbus slave id? I have not seen any option for that. Finally I want to ask if there is some documentation available more specific about the modbus communication implemented in the CODESYS Control for Raspberry Pi. I wanted to know, between...</summary></entry><entry><title>fjcano posted a comment on discussion Visualization 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Visualization/thread/de8566349b/?limit=25#20f4" rel="alternate"/><published>2020-12-15T14:33:36.937000Z</published><updated>2020-12-15T14:33:36.937000Z</updated><author><name>fjcano</name><uri>https://forge.codesys.com/u/fjcano/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Visualization/thread/de8566349b/?limit=25#20f4</id><summary type="html">Hello, I´m working with the Trend recording element. In the visualization i want to implement a fixed scale for the graph. However when I access to the screen configuration the representation mode is fixed to automatic and i cant change it. I have tried different things but I´m unable to solve this. Any help would be grateful. Regards</summary></entry><entry><title>fjcano modified a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/bbb6a350f9/?limit=25#2d84" rel="alternate"/><published>2020-11-04T15:46:53.648000Z</published><updated>2020-11-04T15:46:53.648000Z</updated><author><name>fjcano</name><uri>https://forge.codesys.com/u/fjcano/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/bbb6a350f9/?limit=25#2d84</id><summary type="html">Hello, I have a Raspberry PI 4 Model B, with the CODESYS CONTROL for RASPBERRY PI 3.5.16.20 runtime installed on it. I have bought a four relais module to control an AC load. In specific, the following one: https://www.az-delivery.de/es/products/4-relais-module I have connected the GPIOS 1 (3V3), 9 (GND), AND 11, (GPIO17) to the module and if I execute this simple python script i can command the connection/disconnection of the relay: import RPi.GPIO as GPIO from time import sleep GPIO.setmode(GPIO.BCM)...</summary></entry><entry><title>fjcano posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/bbb6a350f9/?limit=25#2d84" rel="alternate"/><published>2020-11-04T15:46:06.506000Z</published><updated>2020-11-04T15:46:06.506000Z</updated><author><name>fjcano</name><uri>https://forge.codesys.com/u/fjcano/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/bbb6a350f9/?limit=25#2d84</id><summary type="html">Hello, I have a Raspberry PI 4 Model B, with the CODESYS CONTROL for RASPBERRY PI 3.5.16.20 runtime installed on it. I have bought a four relais module to control an AC load. In specific, the following one: https://www.az-delivery.de/es/products/4-relais-module I have connected the GPIOS 1 (3V3), 9 (GND), AND 11, (GPIO17) to the module and if I executed this simple python script i can command the connection/disconnection of the relay: import RPi.GPIO as GPIO from time import sleep GPIO.setmode(GPIO.BCM)...</summary></entry><entry><title>fjcano posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/b84bd3a096/?limit=25#7b19" rel="alternate"/><published>2020-10-22T11:53:31.230000Z</published><updated>2020-10-22T11:53:31.230000Z</updated><author><name>fjcano</name><uri>https://forge.codesys.com/u/fjcano/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/b84bd3a096/?limit=25#7b19</id><summary type="html">Hello, I´m trying to simulate the control of a heating system. Then end of the control is a PID of the error between a power reference I generated internally for the heating system and the actual power consumption of the heating system. To test this control I want to implement a retard transfer function that simulates the power consumption. The idea is that the power consumption of the heating system will be the output of the PID with a retard of, for example, 5 second. The thing is that I don´t...</summary></entry><entry><title>fjcano posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/8bea812f4e/?limit=25#a130" rel="alternate"/><published>2020-10-15T07:17:03.865000Z</published><updated>2020-10-15T07:17:03.865000Z</updated><author><name>fjcano</name><uri>https://forge.codesys.com/u/fjcano/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/8bea812f4e/?limit=25#a130</id><summary type="html">Hello, I have been reading some old post but I´m not enable to connect my Raspberry Pi to a modbus USB - RS485 adapter. I haver a Raspberry 4 with the last version of the CODESYS Control runtime on it. I have configured the .cfg file as you said in other posts: " [SysCom] Linux.Devicefile=/dev/ttyUSB portnum := COM.SysCom.SYS_COMPORT1; " And apparently in CODESYS the port is working but the slave is giving me a a Timeout error I´m unable to resolve in spite of have modified it. I attach some ima...</summary></entry><entry><title>fjcano posted a comment on discussion Automation Server</title><link href="https://forge.codesys.com/forge/talk/automation_server/thread/c4f0bafdc9/?limit=25#88ad" rel="alternate"/><published>2020-09-28T08:41:23.201000Z</published><updated>2020-09-28T08:41:23.201000Z</updated><author><name>fjcano</name><uri>https://forge.codesys.com/u/fjcano/profile/</uri></author><id>https://forge.codesys.com/forge/talk/automation_server/thread/c4f0bafdc9/?limit=25#88ad</id><summary type="html">Also mark I have installed the version 1.12.0.0 of the CODESYS Automation Server Connector and the CODESYS IDE V3.5 SP16 Patch 2</summary></entry><entry><title>fjcano posted a comment on discussion Automation Server</title><link href="https://forge.codesys.com/forge/talk/automation_server/thread/c4f0bafdc9/?limit=25#e74e" rel="alternate"/><published>2020-09-28T08:39:05.770000Z</published><updated>2020-09-28T08:39:05.770000Z</updated><author><name>fjcano</name><uri>https://forge.codesys.com/u/fjcano/profile/</uri></author><id>https://forge.codesys.com/forge/talk/automation_server/thread/c4f0bafdc9/?limit=25#e74e</id><summary type="html">Hello, I´m having some problems in the configuration of the Edge Gateway for the connection with the Automation Server. I want to configure my PC as Edge Gateway following the instructions showed in this video: https://www.youtube.com/watch?v=iiPKyyO4M00. The problem is when i want to allow the configuration mode in the Edge Gateway this error appear. I have restarted the CODESYS IDE, the Gateway, uninstall and download again the Edge Gateway program, but this problem persist. What can i do?</summary></entry></feed>