<?xml version="1.0" encoding="utf-8"?>
<feed xml:lang="en" xmlns="http://www.w3.org/2005/Atom"><title>Activity for fmon</title><link href="https://forge.codesys.com/u/fmon/activity/" rel="alternate"/><id>https://forge.codesys.com/u/fmon/activity/</id><updated>2025-03-18T10:27:06.252000Z</updated><subtitle>Recent activity for fmon</subtitle><entry><title>fmon modified a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/70f789268f/?limit=25#44c8" rel="alternate"/><published>2025-03-18T10:27:06.252000Z</published><updated>2025-03-18T10:27:06.252000Z</updated><author><name>fmon</name><uri>https://forge.codesys.com/u/fmon/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/70f789268f/?limit=25#44c8</id><summary type="html">Problem solved The client modbus cycle time was linked to a task at 500ms. Whereas the channel modbus was at 200ms. Certainly problem of packages synchronisation. I let the client modbus cycle time to be handled by itself (See attachement) --&gt; "Use the bus cyle time parameters" (traduce from french) See attachement</summary></entry><entry><title>fmon posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/70f789268f/?limit=25#44c8" rel="alternate"/><published>2025-03-18T10:25:34.018000Z</published><updated>2025-03-18T10:25:34.018000Z</updated><author><name>fmon</name><uri>https://forge.codesys.com/u/fmon/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/70f789268f/?limit=25#44c8</id><summary type="html">Problem solved The client modbus cycle time was linked to a task at 500ms. Whereas the channel modbus was at 200ms. Certainly problem of packages synchronisation. I let the client modbus cycle time to be handled by itself (See attachement) --&gt; "Use the bus cyle time parameters" (traduce from french) See attachement</summary></entry><entry><title>fmon posted a comment on discussion Codesys V2.3 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/CODESYS-V2/thread/e4b047d577/?limit=25#234a" rel="alternate"/><published>2025-03-18T10:17:48.765000Z</published><updated>2025-03-18T10:17:48.765000Z</updated><author><name>fmon</name><uri>https://forge.codesys.com/u/fmon/profile/</uri></author><id>https://forge.codesys.com/forge/talk/CODESYS-V2/thread/e4b047d577/?limit=25#234a</id><summary type="html">Problem solved The client modbus cycle time was linked to a task at 500ms. Whereas the channel modbus was at 200ms. Certainly problem of packages synchronisation. I let the client modbus cycle time to be handled by itself (See attachement) --&gt; "Use the bus cyle time parameters" (traduce from french) See attachement</summary></entry><entry><title>fmon posted a comment on discussion Codesys V2.3 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/CODESYS-V2/thread/e4b047d577/?limit=25#c2a2" rel="alternate"/><published>2025-03-17T08:52:52.486000Z</published><updated>2025-03-17T08:52:52.486000Z</updated><author><name>fmon</name><uri>https://forge.codesys.com/u/fmon/profile/</uri></author><id>https://forge.codesys.com/forge/talk/CODESYS-V2/thread/e4b047d577/?limit=25#c2a2</id><summary type="html">Hello, I am using codesys Modbus TCP client (4.4.0.0) to communicate with a python modbus server (package pyModbusTCP). I first start my python server on the distant machine. After a fresh codesys compilation, a plc connection/transfer and a PLC run, the modbus connection is OK. Every time in this context the connection is created correctly. When I shut down the server, the modbus connection falls, that is normal. When I restart the python server, impossible to recreate the modbus connexion. With...</summary></entry><entry><title>fmon modified a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/70f789268f/?limit=25#8687" rel="alternate"/><published>2025-03-14T18:16:46.967000Z</published><updated>2025-03-14T18:16:46.967000Z</updated><author><name>fmon</name><uri>https://forge.codesys.com/u/fmon/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/70f789268f/?limit=25#8687</id><summary type="html">Hello, I am using codesys Modbus TCP client (4.4.0.0) to communicate with a python modbus server (package pyModbusTCP). I first start my python server on the distant machine. After a fresh codesys compilation, a plc connection/transfer and a PLC run, the modbus connection is OK. Every time in this context the connection is created correctly. When I shut down the server, the modbus connection falls, that is normal. When I restart the python server, impossible to recreate the modbus connexion. With...</summary></entry></feed>