<?xml version="1.0" encoding="utf-8"?>
<feed xml:lang="en" xmlns="http://www.w3.org/2005/Atom"><title>Activity for gurkan</title><link href="https://forge.codesys.com/u/gurkan/activity/" rel="alternate"/><id>https://forge.codesys.com/u/gurkan/activity/</id><updated>2024-02-19T08:28:19.288000Z</updated><subtitle>Recent activity for gurkan</subtitle><entry><title>gurkan posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/19ba0967af/?limit=25#8a4b" rel="alternate"/><published>2024-02-19T08:28:19.288000Z</published><updated>2024-02-19T08:28:19.288000Z</updated><author><name>gurkan</name><uri>https://forge.codesys.com/u/gurkan/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/19ba0967af/?limit=25#8a4b</id><summary type="html">2000 works. When testing with UA Expert there is a timeout from the OPCUA Server when trying to subscribe to the variable CPU do not seems to be to affected. The memory(RAM) however is building up</summary></entry><entry><title>gurkan posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/19ba0967af/?limit=25#78fc" rel="alternate"/><published>2024-02-16T09:10:52.704000Z</published><updated>2024-02-16T09:10:52.704000Z</updated><author><name>gurkan</name><uri>https://forge.codesys.com/u/gurkan/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/19ba0967af/?limit=25#78fc</id><summary type="html">We are using codesys 3.5.16.30 and we have a array with strings of length 5000. We are having issues subscribing to this variable from an OPCUA client. Is there any limit in the OPCUA Server in codesys for how long an array can be on the opcua server?</summary></entry><entry><title>gurkan posted a comment on discussion Engineering</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/8a11fdf67e/?limit=25#a61a" rel="alternate"/><published>2020-06-16T12:49:39.001000Z</published><updated>2020-06-16T12:49:39.001000Z</updated><author><name>gurkan</name><uri>https://forge.codesys.com/u/gurkan/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/8a11fdf67e/?limit=25#a61a</id><summary type="html">After we updated codesys from 3.5.13.20 to 3.5.16.0 we get an error when OPCUA clients try to connect: OpcUa_Endpoint_EndSendResponse: Error 0x80310000! Cancelling response Any input would be helpful!</summary></entry></feed>