<?xml version="1.0" encoding="utf-8"?>
<feed xml:lang="en" xmlns="http://www.w3.org/2005/Atom"><title>Activity for husarz17</title><link href="https://forge.codesys.com/u/husarz17/activity/" rel="alternate"/><id>https://forge.codesys.com/u/husarz17/activity/</id><updated>2026-04-29T07:36:05.454000Z</updated><subtitle>Recent activity for husarz17</subtitle><entry><title>husarz17 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/0c0db81e2e/?limit=25#1e19" rel="alternate"/><published>2026-04-29T07:36:05.454000Z</published><updated>2026-04-29T07:36:05.454000Z</updated><author><name>husarz17</name><uri>https://forge.codesys.com/u/husarz17/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/0c0db81e2e/?limit=25#1e19</id><summary type="html">Hi, I have similar issue. Is that possible to use more than 4096 registers with Modbus RTU slave?</summary></entry><entry><title>husarz17 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/66c89087ec/?limit=25#05dd" rel="alternate"/><published>2026-04-20T11:50:03.846000Z</published><updated>2026-04-20T11:50:03.846000Z</updated><author><name>husarz17</name><uri>https://forge.codesys.com/u/husarz17/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/66c89087ec/?limit=25#05dd</id><summary type="html">Good to know there's a solution to this problem. I hope you'll be able to share it with me. I can't wait to hear about it.</summary></entry><entry><title>husarz17 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/66c89087ec/?limit=25#b047" rel="alternate"/><published>2026-04-13T20:32:28.788000Z</published><updated>2026-04-13T20:32:28.788000Z</updated><author><name>husarz17</name><uri>https://forge.codesys.com/u/husarz17/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/66c89087ec/?limit=25#b047</id><summary type="html">Hi nulltrace, Thanks for the info. I'm waiting to hear back from you. Take care!</summary></entry><entry><title>husarz17 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/66c89087ec/?limit=25#9bf8" rel="alternate"/><published>2026-04-01T09:09:11.740000Z</published><updated>2026-04-01T09:09:11.740000Z</updated><author><name>husarz17</name><uri>https://forge.codesys.com/u/husarz17/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/66c89087ec/?limit=25#9bf8</id><summary type="html">My codesys is 3.5.21.30. I am using function ModbusServer from library ModbusTCP_Slave. The reason is that I need share 9000 Holding registers. By standard configuration it is only 4096. fbMbTcpDevice: ModbusTCP_Slave.ModbusServer; fbMbTcpDevice( wPort := 502, pInputData := ADR(awInputReg), pOutputData := ADR(awHoldingReg), uiInputDataSize := 10, uiOutputDataSize := 9000, xEnable := TRUE, tTimeout := 10000, InterfaceName := "eth0", xBusy =&gt; xBusy, xError =&gt; xError, byClientConnections =&gt; byConnections...</summary></entry><entry><title>husarz17 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/66c89087ec/?limit=25#8a78" rel="alternate"/><published>2026-03-31T14:50:15.075000Z</published><updated>2026-03-31T14:50:15.075000Z</updated><author><name>husarz17</name><uri>https://forge.codesys.com/u/husarz17/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/66c89087ec/?limit=25#8a78</id><summary type="html">I need the same issue. In my application TCP server on raspberry (codesys) should have UnitID 1. But it only works when I am requesting with UnitID 255. And my application can't work with this parameters...</summary></entry></feed>