<?xml version="1.0" encoding="utf-8"?>
<feed xml:lang="en" xmlns="http://www.w3.org/2005/Atom"><title>Activity for kut69</title><link href="https://forge.codesys.com/u/kut69/activity/" rel="alternate"/><id>https://forge.codesys.com/u/kut69/activity/</id><updated>2025-05-19T05:26:55.483000Z</updated><subtitle>Recent activity for kut69</subtitle><entry><title>kut69 posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/05fa655d71/?limit=25#8583" rel="alternate"/><published>2025-05-19T05:26:55.483000Z</published><updated>2025-05-19T05:26:55.483000Z</updated><author><name>kut69</name><uri>https://forge.codesys.com/u/kut69/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/05fa655d71/?limit=25#8583</id><summary type="html">Hi, I am interested in details about the .ret file in the filesystem. I have already a project where the file is used (write on demand, read by start) and I want to share it as 'default input' for test devices using the identical application. Opening the .ret file content in a hex editor (I only use a single string retain var) I asked myself what the meaning of the first 24 bytes is. It neither contains a handle to the application nor a reference to the variable. Is this maybe a timestamp? Or a CRC/checksum?...</summary></entry><entry><title>kut69 posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/3d80d2f55a/?limit=25#8c23" rel="alternate"/><published>2022-12-02T06:48:03.846000Z</published><updated>2022-12-02T06:48:03.846000Z</updated><author><name>kut69</name><uri>https://forge.codesys.com/u/kut69/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/3d80d2f55a/?limit=25#8c23</id><summary type="html">Hi experts, I have to setup a test environment in which different EtherCAT slaves need to be tested, each of them using a different topology (because of different port count). Is it possible to configure multiple master SW instances in CoDeSys acessing the same HW (port), activating only one of them at runtime? I want to avoid a complex bus topology including inactive/disabled slaves. See attachment for better understanding... Thanks for any reply, Thomas</summary></entry><entry><title>kut69 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/cd00f6c317/?limit=25#1062" rel="alternate"/><published>2022-07-06T08:10:07.157000Z</published><updated>2022-07-06T08:10:07.157000Z</updated><author><name>kut69</name><uri>https://forge.codesys.com/u/kut69/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/cd00f6c317/?limit=25#1062</id><summary type="html">Hi, my question is related to that topic. Is it possible to use 2 "instances" of the EtherCAT master library simultanuous to access 2 different ports for 2 different fieldbus rings?</summary></entry><entry><title>kut69 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/31035f0ef2/?limit=25#dbca" rel="alternate"/><published>2022-02-18T10:32:06.957000Z</published><updated>2022-02-18T10:32:06.957000Z</updated><author><name>kut69</name><uri>https://forge.codesys.com/u/kut69/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/31035f0ef2/?limit=25#dbca</id><summary type="html">Hi experts! For enhanced logging I replaced default syslog on my RasPi CM4 Linux by syslog-ng. My Linux driver application worked and I was able to send log messages, but now CoDeSys runs into an exception. It looks like CoDeSys requires syslog (or one oft its a sub components) for logging or file accesses. Usage (installation) of rsyslog fails bacause of missing components on our Linux. Is there any chance to make syslog-ng work together with CoDeSys? Or has anyone experiences with other tools?...</summary></entry><entry><title>kut69 posted a comment on discussion Deutsch 🇩🇪</title><link href="https://forge.codesys.com/forge/talk/Deutsch/thread/d545b5905b/?limit=25#975b" rel="alternate"/><published>2021-12-10T07:41:38.722000Z</published><updated>2021-12-10T07:41:38.722000Z</updated><author><name>kut69</name><uri>https://forge.codesys.com/u/kut69/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Deutsch/thread/d545b5905b/?limit=25#975b</id><summary type="html">Hallo zusammen, ich habe einen ähnlichen Effekt wie in https://forge.codesys.com/forge/talk/Deutsch/thread/d6dccc9716/ und https://forge.codesys.com/forge/talk/Runtime/thread/2ca46722e5/ bereits beschrieben. Da ich CoDeSys hauptsächlich als Engineering-Tool nutze (RunTime läuft auf Linux), ist die Control Win V3 bei mir nur im Demo-Modus mit 120 Minuten Zeitbeschränkung aktiv, hauptsächlich für kurze Tests/Evaluierungen oder auch mal zur Projektierung eines Busaufbaus. Wenn ich den 6. Netzwerkadapter...</summary></entry></feed>