<?xml version="1.0" encoding="utf-8"?>
<feed xml:lang="en" xmlns="http://www.w3.org/2005/Atom"><title>Activity for mk21y</title><link href="https://forge.codesys.com/u/mk21y/activity/" rel="alternate"/><id>https://forge.codesys.com/u/mk21y/activity/</id><updated>2023-03-24T13:34:33.813000Z</updated><subtitle>Recent activity for mk21y</subtitle><entry><title>mk21y posted a comment on discussion Codesys V2.3 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/CODESYS-V2/thread/2f59775370/?limit=25#3231/5c1f" rel="alternate"/><published>2023-03-24T13:34:33.813000Z</published><updated>2023-03-24T13:34:33.813000Z</updated><author><name>mk21y</name><uri>https://forge.codesys.com/u/mk21y/profile/</uri></author><id>https://forge.codesys.com/forge/talk/CODESYS-V2/thread/2f59775370/?limit=25#3231/5c1f</id><summary type="html">Hello, Thank you for the help. I'm new to codesys so i'm a little confused when doing these programs. Can I ask you to send me a screenshot of the code and ladder connection? Thank you again for the help 😃 .</summary></entry><entry><title>mk21y modified a comment on discussion Codesys V2.3 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/CODESYS-V2/thread/2f59775370/?limit=25#da98" rel="alternate"/><published>2023-03-24T07:44:44.923000Z</published><updated>2023-03-24T07:44:44.923000Z</updated><author><name>mk21y</name><uri>https://forge.codesys.com/u/mk21y/profile/</uri></author><id>https://forge.codesys.com/forge/talk/CODESYS-V2/thread/2f59775370/?limit=25#da98</id><summary type="html">Hello I'm using codesys v3.3 to meassure the values of a SENECA (S604E-6-MOD) wattmeter, but while reading the values for the Phase 3 current, i'm getting wrong values, the reason being that when I input the holding register (HEX: 1012) it shows the wrong values (it reads 2 registers 1012 and 1013) and the when I input a value (HEX: 1013) it reads 2 registers 1013 and 1014 but the problem is that the 1014 register is the register for Neutral current. Is there any way to combine the register or switch...</summary></entry><entry><title>mk21y posted a comment on discussion Codesys V2.3 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/CODESYS-V2/thread/2f59775370/?limit=25#da98" rel="alternate"/><published>2023-03-24T07:44:02.568000Z</published><updated>2023-03-24T07:44:02.568000Z</updated><author><name>mk21y</name><uri>https://forge.codesys.com/u/mk21y/profile/</uri></author><id>https://forge.codesys.com/forge/talk/CODESYS-V2/thread/2f59775370/?limit=25#da98</id><summary type="html">Hello I'm using codesys v3.3 to meassure the values of a SENECA (S604E-6-MOD) wattmeter, but while reading the values for the Phase 3 current, i'm getting wrong values, the reason being that when I input the holding register (HEX: 1012) it shows the wrong values (it reads 2 registers 1012 and 1013) and the when I input a value (HEX: 1013) it reads 2 registers 1013 and 1014 but the problem is that the 1014 register is the register for Neutral current. Is there any way to combine the register or switch...</summary></entry></feed>