<?xml version="1.0" encoding="utf-8"?>
<feed xml:lang="en" xmlns="http://www.w3.org/2005/Atom"><title>Activity for nitroboy</title><link href="https://forge.codesys.com/u/nitroboy/activity/" rel="alternate"/><id>https://forge.codesys.com/u/nitroboy/activity/</id><updated>2021-09-21T11:54:46.744000Z</updated><subtitle>Recent activity for nitroboy</subtitle><entry><title>nitroboy posted a comment on discussion Visualization 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Visualization/thread/2ccbcb0493/?limit=25#879b" rel="alternate"/><published>2021-09-21T11:54:46.744000Z</published><updated>2021-09-21T11:54:46.744000Z</updated><author><name>nitroboy</name><uri>https://forge.codesys.com/u/nitroboy/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Visualization/thread/2ccbcb0493/?limit=25#879b</id><summary type="html">As I wrote in the first post, I have the CurrentVisu Variable Disabled... But i'm suspecting the PLC didn't take the change, can I disable it in the program?</summary></entry><entry><title>nitroboy posted a comment on discussion Visualization 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Visualization/thread/2ccbcb0493/?limit=25#2aee" rel="alternate"/><published>2021-09-21T11:12:54.052000Z</published><updated>2021-09-21T11:12:54.052000Z</updated><author><name>nitroboy</name><uri>https://forge.codesys.com/u/nitroboy/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Visualization/thread/2ccbcb0493/?limit=25#2aee</id><summary type="html">Hey, i have a strange problem with webisu clients, If I have more than one client connected the visualisation is not independent, it switches frames if either user makes an input. i tried making two WebVisus with different staring visu's but still not working CurrentVisu variable is unchecked. Also when I login as an user on one client then it jumps between users, because the other client is not logged in. I didn't find any solutions to this in this forum, any help would be appreciated. Cheers</summary></entry><entry><title>nitroboy posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/419b251bdb/?limit=25#a484" rel="alternate"/><published>2021-07-26T09:15:01.278000Z</published><updated>2021-07-26T09:15:01.278000Z</updated><author><name>nitroboy</name><uri>https://forge.codesys.com/u/nitroboy/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/419b251bdb/?limit=25#a484</id><summary type="html">Hey, Until now i found everything in this forum but not this information :D. So, I'm trying for transfer a file from a Wago PLC to Visu PC. I've fixed error 7. But now I have error 4 (Error during file transfer). If I enter a wrong filename i get error 6. So that mean i have the right file selected (/media/sd/CSV_Files/logfile.csv). Did someone have the same problem ?? Any info would be helpful, thanks. Cheers Elvis K.</summary></entry></feed>