<?xml version="1.0" encoding="utf-8"?>
<feed xml:lang="en" xmlns="http://www.w3.org/2005/Atom"><title>Activity for sanyosd2</title><link href="https://forge.codesys.com/u/sanyosd2/activity/" rel="alternate"/><id>https://forge.codesys.com/u/sanyosd2/activity/</id><updated>2021-07-02T10:02:31.472000Z</updated><subtitle>Recent activity for sanyosd2</subtitle><entry><title>sanyosd2 posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/4596fd8aa5/?limit=25#13eb" rel="alternate"/><published>2021-07-02T10:02:31.472000Z</published><updated>2021-07-02T10:02:31.472000Z</updated><author><name>sanyosd2</name><uri>https://forge.codesys.com/u/sanyosd2/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/4596fd8aa5/?limit=25#13eb</id><summary type="html">Sorry, the first image was not attached.</summary></entry><entry><title>sanyosd2 posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/4596fd8aa5/?limit=25#4d3a" rel="alternate"/><published>2021-07-02T09:57:20.077000Z</published><updated>2021-07-02T09:57:20.077000Z</updated><author><name>sanyosd2</name><uri>https://forge.codesys.com/u/sanyosd2/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/4596fd8aa5/?limit=25#4d3a</id><summary type="html">I am trying to get the linkup status of an Ethernet port. I'm using SysEthernetPortConfigAndStatus, but the value I get is Unknown. On Linux, the linkup is working, but is there something wrong with the way I use it? Or do I need to configure something in order to use it?</summary></entry><entry><title>sanyosd2 posted a comment on discussion Motion 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Motion/thread/2d1c7059d4/?limit=25#91b9" rel="alternate"/><published>2021-03-10T02:27:42.169000Z</published><updated>2021-03-10T02:27:42.169000Z</updated><author><name>sanyosd2</name><uri>https://forge.codesys.com/u/sanyosd2/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Motion/thread/2d1c7059d4/?limit=25#91b9</id><summary type="html">I understood that the problem is on the slave side. Since this phenomenon can be avoided by the PLC program, we will try to program it according to the slave.</summary></entry><entry><title>sanyosd2 posted a comment on discussion Motion 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Motion/thread/2d1c7059d4/?limit=25#8c89" rel="alternate"/><published>2021-02-22T10:55:21.888000Z</published><updated>2021-02-22T10:55:21.888000Z</updated><author><name>sanyosd2</name><uri>https://forge.codesys.com/u/sanyosd2/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Motion/thread/2d1c7059d4/?limit=25#8c89</id><summary type="html">The problem seems to occur when the axis reference (AXIS_REF) is initialized. The reason for this is that the "Fault Reset" bit is set when SMC3_ReinitDrive is executed. It is no problem to reset the drive error explicitly by executing MC_Reset or SMC3_ReinitDrive. However, if the drive error that occurred before the establishment of EtherCAT communication is reset in a non-explicit way (this phenomenon), it may cause unexpected problems and should be avoided.</summary></entry><entry><title>sanyosd2 posted a comment on discussion Motion 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Motion/thread/2d1c7059d4/?limit=25#566e" rel="alternate"/><published>2021-02-22T07:57:06.010000Z</published><updated>2021-02-22T07:57:06.010000Z</updated><author><name>sanyosd2</name><uri>https://forge.codesys.com/u/sanyosd2/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Motion/thread/2d1c7059d4/?limit=25#566e</id><summary type="html">In the project, there is no program, only the system configuration (see attached file).Why is the Controlword set?</summary></entry><entry><title>sanyosd2 posted a comment on discussion Motion 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Motion/thread/2d1c7059d4/?limit=25#457c" rel="alternate"/><published>2021-02-22T01:33:55.579000Z</published><updated>2021-02-22T01:33:55.579000Z</updated><author><name>sanyosd2</name><uri>https://forge.codesys.com/u/sanyosd2/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Motion/thread/2d1c7059d4/?limit=25#457c</id><summary type="html">There are no errors in the drive. "Fault Reset" bit is automatically set regardless of whether the drive is in error.</summary></entry><entry><title>sanyosd2 posted a comment on discussion Motion 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Motion/thread/2d1c7059d4/?limit=25#0839" rel="alternate"/><published>2021-02-17T09:52:16.846000Z</published><updated>2021-02-17T09:52:16.846000Z</updated><author><name>sanyosd2</name><uri>https://forge.codesys.com/u/sanyosd2/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Motion/thread/2d1c7059d4/?limit=25#0839</id><summary type="html">A few millimeters after synchronizing with the slave in EtherCAT communication, the "Fault Reset" bit is automatically set to TRUE (see attached file). I want to disable this, is there any way?</summary></entry><entry><title>sanyosd2 posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/0acac552f4/?limit=25#7fa2" rel="alternate"/><published>2020-12-28T00:48:08.788000Z</published><updated>2020-12-28T00:48:08.788000Z</updated><author><name>sanyosd2</name><uri>https://forge.codesys.com/u/sanyosd2/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/0acac552f4/?limit=25#7fa2</id><summary type="html">Hi, I want to connect to AWS using the client certificate created by "One-Click certificate creation" (see attachment). However, the key (.pki \ own \ key) is not generated even if the issued client certificate is registered using "Security Agent". Therefore, I converted the issued private key to DER format and saved it in .pki \ own \ key, but the error "TlsCreateContext2: Private key for certificate / CN = AWS IoT Certificate not available" occurs. Will it only support client certificates issued...</summary></entry></feed>