<?xml version="1.0" encoding="utf-8"?>
<feed xml:lang="en" xmlns="http://www.w3.org/2005/Atom"><title>Activity for Scoobler</title><link href="https://forge.codesys.com/u/scoobler/activity/" rel="alternate"/><id>https://forge.codesys.com/u/scoobler/activity/</id><updated>2022-09-26T16:41:38.606000Z</updated><subtitle>Recent activity for Scoobler</subtitle><entry><title>Scoobler posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/f0919ff568/?limit=25#8400" rel="alternate"/><published>2022-09-26T16:41:38.606000Z</published><updated>2022-09-26T16:41:38.606000Z</updated><author><name>Scoobler</name><uri>https://forge.codesys.com/u/scoobler/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/f0919ff568/?limit=25#8400</id><summary type="html">Hi i-campbell, I tried adding the 'slave COM port' under the TCP Slave - however there was no SlaveAddress - the only thing was an output showing the usiUnitID - however there didn't appear to be a way to set this in the code.</summary></entry><entry><title>Scoobler modified a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/f0919ff568/?limit=25#651f" rel="alternate"/><published>2022-09-23T14:07:33.635000Z</published><updated>2022-09-23T14:07:33.635000Z</updated><author><name>Scoobler</name><uri>https://forge.codesys.com/u/scoobler/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/f0919ff568/?limit=25#651f</id><summary type="html">Thanks for the suggestion, unfortunately it is Modbus TCP, the SlaveAddress is for Modbus RTU and isn't present on the communication settings for Modbus TCP. Setting the Unit ID is available via the GUI, but I can't seem to find it to change other than at compile time.</summary></entry><entry><title>Scoobler modified a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/f0919ff568/?limit=25#651f" rel="alternate"/><published>2022-09-23T14:03:44.573000Z</published><updated>2022-09-23T14:03:44.573000Z</updated><author><name>Scoobler</name><uri>https://forge.codesys.com/u/scoobler/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/f0919ff568/?limit=25#651f</id><summary type="html">Thanks for the suggestion, unfortunately it is Modbus TCP, the SlaveAddress is for Modbus RTU and isn't present on the communication settings for Modbus TCP.</summary></entry><entry><title>Scoobler posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/f0919ff568/?limit=25#651f" rel="alternate"/><published>2022-09-23T14:03:32.933000Z</published><updated>2022-09-23T14:03:32.933000Z</updated><author><name>Scoobler</name><uri>https://forge.codesys.com/u/scoobler/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/f0919ff568/?limit=25#651f</id><summary type="html">Thanks for the suggestion, unfortunately it is Modbus TCP, the SlaveAddress is for Modbus RTU and isn't present on the communication settings for Modbus TCP.</summary></entry><entry><title>Scoobler posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/f0919ff568/?limit=25#f3fc" rel="alternate"/><published>2022-09-23T13:14:14.644000Z</published><updated>2022-09-23T13:14:14.644000Z</updated><author><name>Scoobler</name><uri>https://forge.codesys.com/u/scoobler/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/f0919ff568/?limit=25#f3fc</id><summary type="html">Hello, I have a project with a package controller fitted to a machine - it has a feature where the overall package parameters are available via Unit ID 100 - this is static. The machine specific details are then available via a different Unit ID. When several machines are plugged into each other, these IDs will increment - so the package controller (an IPC) will respond for the entire package via Unit ID 100, but if I want to check details for machine 1, it will be Unit ID 1, for machine 2 it would...</summary></entry></feed>