<?xml version="1.0" encoding="utf-8"?>
<feed xml:lang="en" xmlns="http://www.w3.org/2005/Atom"><title>Activity for squiggleypuff</title><link href="https://forge.codesys.com/u/squiggleypuff/activity/" rel="alternate"/><id>https://forge.codesys.com/u/squiggleypuff/activity/</id><updated>2024-04-09T02:21:33.205000Z</updated><subtitle>Recent activity for squiggleypuff</subtitle><entry><title>squiggleypuff posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/79fa8d82e5/?limit=25#8180" rel="alternate"/><published>2024-04-09T02:21:33.205000Z</published><updated>2024-04-09T02:21:33.205000Z</updated><author><name>squiggleypuff</name><uri>https://forge.codesys.com/u/squiggleypuff/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/79fa8d82e5/?limit=25#8180</id><summary type="html">Turns out Modbus was working despite the pre-compiler errors; I was reading the wrong addresses of the slave device, which was why I was seeing all 0s. Thanks for ignoring me.</summary></entry><entry><title>squiggleypuff posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/79fa8d82e5/?limit=25#cd9b" rel="alternate"/><published>2024-04-08T16:16:30.506000Z</published><updated>2024-04-08T16:16:30.506000Z</updated><author><name>squiggleypuff</name><uri>https://forge.codesys.com/u/squiggleypuff/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/79fa8d82e5/?limit=25#cd9b</id><summary type="html">Bumping for visibility, still unable to get Modbus working on this thing.</summary></entry><entry><title>squiggleypuff posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/79fa8d82e5/?limit=25#817e" rel="alternate"/><published>2024-04-04T01:30:00.236000Z</published><updated>2024-04-04T01:30:00.236000Z</updated><author><name>squiggleypuff</name><uri>https://forge.codesys.com/u/squiggleypuff/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/79fa8d82e5/?limit=25#817e</id><summary type="html">I'm having a tough time trying to get Modbus working on a Festo CPX-E PLC; it throws these pre-compiler errors as soon as I add in my Modbus TCP Master 3.5.12.30 to my project: I'm confused about the C0046 error, as I have IODrvModbusTCP 4.3.0.0 Library installed. So I thought maybe I needed to use the newest Modbus TCP Master 4.3.0.0, which is in my device repository: However, whenever I go to add this underneath the Ethernet adapter (which is version 4.2.0.0), the only TCP Master version available...</summary></entry><entry><title>squiggleypuff posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/c1822181c7/?limit=25#75f1" rel="alternate"/><published>2024-03-19T18:31:11.914000Z</published><updated>2024-03-19T18:31:11.914000Z</updated><author><name>squiggleypuff</name><uri>https://forge.codesys.com/u/squiggleypuff/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/c1822181c7/?limit=25#75f1</id><summary type="html">I have a project with a Festo CPX-E-CEC-C1-PN PLC (Run-time version 3.5.12.50) that I have been developing on just fine using Codesys V3.5 SP19 Patch 5 (64bit). I am at the stage where I wanted to use the Festo HMI screen, and have added a RemoteTargetVisu object to my application. After adding this object, I am no longer able to log in to the PLC as I get an Unresolved Reference warning for 'USERMGRUSERGETPROPERTY' towards the end of the download process. I was able to find this post (https://forge.codesys.com/forge/talk/Visualization/thread/fc686a6cb2/)...</summary></entry></feed>