<?xml version="1.0" encoding="utf-8"?>
<feed xml:lang="en" xmlns="http://www.w3.org/2005/Atom"><title>Activity for thebushyone</title><link href="https://forge.codesys.com/u/thebushyone/activity/" rel="alternate"/><id>https://forge.codesys.com/u/thebushyone/activity/</id><updated>2023-03-23T08:55:08.593000Z</updated><subtitle>Recent activity for thebushyone</subtitle><entry><title>thebushyone posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/38b8de657a/?limit=25#5f59" rel="alternate"/><published>2023-03-23T08:55:08.593000Z</published><updated>2023-03-23T08:55:08.593000Z</updated><author><name>thebushyone</name><uri>https://forge.codesys.com/u/thebushyone/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/38b8de657a/?limit=25#5f59</id><summary type="html">Did anyone get to the bottom of this problem? The Python scripts only execute certain commands within them when executed from Codesys. Direct from a the LXTerminal everything work fine. [SysProcess] AllowAll in both file positions and python scrips in the /var/opt/codesys file Thanks in advance</summary></entry><entry><title>thebushyone posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/38b8de657a/?limit=25#29ae" rel="alternate"/><published>2023-03-23T08:55:04.518000Z</published><updated>2023-03-23T08:55:04.518000Z</updated><author><name>thebushyone</name><uri>https://forge.codesys.com/u/thebushyone/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/38b8de657a/?limit=25#29ae</id><summary type="html">Did anyone get to the bottom of this problem? The Python scripts only execute certain commands within them when executed from Codesys. Direct from a the LXTerminal everything work fine. [SysProcess] AllowAll in both file positions and python scrips in the /var/opt/codesys file Thanks in advance</summary></entry><entry><title>thebushyone posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/bb696fddf6/?limit=25#9b77" rel="alternate"/><published>2022-04-12T10:23:53.651000Z</published><updated>2022-04-12T10:23:53.651000Z</updated><author><name>thebushyone</name><uri>https://forge.codesys.com/u/thebushyone/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/bb696fddf6/?limit=25#9b77</id><summary type="html">I am having the exact same issue trying to use the "Read E2PROM..." button under the same menu. Any help would be appriciated. Regards</summary></entry><entry><title>thebushyone posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/a08c80aecc/?limit=25#5375" rel="alternate"/><published>2022-01-11T12:31:23.119000Z</published><updated>2022-01-11T12:31:23.119000Z</updated><author><name>thebushyone</name><uri>https://forge.codesys.com/u/thebushyone/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/a08c80aecc/?limit=25#5375</id><summary type="html">Hi Paul Bush here. I have an issue where overnight the PLC (Raspberry Pi running 4.2) has requested a user name and password to log in even though one hasn't been set. The device user is listed as Anonymous. I can't load a new DUM2 file as you need to be logged in to achieve this. I have re-installed both the Runtime package and the Gateway with no joy. To be clear, a username and password were never actually set. CoDeSys version 3.5 SP17 patch 1. This currently urgent. I have contacted my UK rep...</summary></entry><entry><title>thebushyone posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/b616007173/?limit=25#de0e" rel="alternate"/><published>2021-01-07T11:57:11.459000Z</published><updated>2021-01-07T11:57:11.459000Z</updated><author><name>thebushyone</name><uri>https://forge.codesys.com/u/thebushyone/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/b616007173/?limit=25#de0e</id><summary type="html">Sorry, should have posted. The issue ended up being that in Modbus TCP Slave I/O Mapping I had to change the Bus Cycle Task to "Task" and the Always Update Variables to "Enabled 2 (always in bus cycle task)". Everything kick in at that point</summary></entry><entry><title>thebushyone posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/b616007173/?limit=25#546a" rel="alternate"/><published>2020-12-18T21:56:53.490000Z</published><updated>2020-12-18T21:56:53.490000Z</updated><author><name>thebushyone</name><uri>https://forge.codesys.com/u/thebushyone/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/b616007173/?limit=25#546a</id><summary type="html">Hi mmxfan, Did you find a solution as I have the exact same problem with the removal of the unit ID</summary></entry></feed>