<?xml version="1.0" encoding="utf-8"?>
<feed xml:lang="en" xmlns="http://www.w3.org/2005/Atom"><title>Activity for tomas111</title><link href="https://forge.codesys.com/u/tomas111/activity/" rel="alternate"/><id>https://forge.codesys.com/u/tomas111/activity/</id><updated>2024-05-20T14:53:14.213000Z</updated><subtitle>Recent activity for tomas111</subtitle><entry><title>tomas111 posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/a8f2db5adb/?limit=25#e2e1" rel="alternate"/><published>2024-05-20T14:53:14.213000Z</published><updated>2024-05-20T14:53:14.213000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/a8f2db5adb/?limit=25#e2e1</id><summary type="html">I ran into a problem. Uploaded an example (https://content.helpme-codesys.com/en/CODESYS%20Examples/_ex_uacapi_example.html) After launch. on the emulator. I see that I am having problems: - UaExpert does not connect. There are many servers but no connection. - I can’t transfer the certificate from quarantine to trusted ones. There is some problem with creating the certificate. CS 19.2. If anyone has had similar problems, please give me advice. Thank you.</summary></entry><entry><title>tomas111 posted a comment on discussion Visualization 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Visualization/thread/47b7530824/?limit=25#5fa6" rel="alternate"/><published>2024-04-17T12:52:52.897000Z</published><updated>2024-04-17T12:52:52.897000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Visualization/thread/47b7530824/?limit=25#5fa6</id><summary type="html">What version of codesys? Need to avoid in any specific element? Try writing %s in the text, it should work. Or better yet, attach a screenshot.</summary></entry><entry><title>tomas111 posted a comment on discussion Visualization 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Visualization/thread/c0aed81be4/?limit=25#b988" rel="alternate"/><published>2024-04-17T12:49:11.130000Z</published><updated>2024-04-17T12:49:11.130000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Visualization/thread/c0aed81be4/?limit=25#b988</id><summary type="html">Hello, the task is not entirely clear. You can make it a dial indicator or a loading slider.</summary></entry><entry><title>tomas111 posted a comment on discussion Visualization 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Visualization/thread/4a134949dd/?limit=25#3974" rel="alternate"/><published>2024-04-17T12:43:53.921000Z</published><updated>2024-04-17T12:43:53.921000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Visualization/thread/4a134949dd/?limit=25#3974</id><summary type="html">Tell me, are there ways to remove the white background from the page loading? I want to change it to a black background. I think there are options with changing /home/codesys_root/PlcLogic/visu/webvisu.htm Perhaps you have already encountered a similar situation. I hope to find the answer to my question.</summary></entry><entry><title>tomas111 posted a comment on discussion Codesys V2.3 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/CODESYS-V2/thread/ad82c6cc3f/?limit=25#19cb" rel="alternate"/><published>2023-10-04T07:05:07.230000Z</published><updated>2023-10-04T07:05:07.230000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/CODESYS-V2/thread/ad82c6cc3f/?limit=25#19cb</id><summary type="html">There was an exact mistake. I did as they wrote. I created a visualization and transferred it from the old one and everything works. CS 3.5 SP 19. Thank you.</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/ffb274d6a2/?limit=25#375f" rel="alternate"/><published>2023-07-04T14:42:31.138000Z</published><updated>2023-07-04T14:42:31.138000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/ffb274d6a2/?limit=25#375f</id><summary type="html">Judging by the responses, no one has done this. Apparently I'm the first?</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/ffb274d6a2/?limit=25#02f1" rel="alternate"/><published>2023-06-22T11:24:45.682000Z</published><updated>2023-06-22T11:24:45.682000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/ffb274d6a2/?limit=25#02f1</id><summary type="html">Target 4.7.0.0 Codesys SP 19</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/ffb274d6a2/?limit=25#7373" rel="alternate"/><published>2023-06-22T11:18:18.419000Z</published><updated>2023-06-22T11:18:18.419000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/ffb274d6a2/?limit=25#7373</id><summary type="html">When adding an alarm configurator, it does not write to the log. Problem with logging. Who thread faced such a problem?</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/5950b0ea93/?limit=25#a7d0/960e" rel="alternate"/><published>2023-06-20T13:42:19.408000Z</published><updated>2023-06-20T13:42:19.408000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/5950b0ea93/?limit=25#a7d0/960e</id><summary type="html">@ codesys.com ?</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/5950b0ea93/?limit=25#0ec3/e75c" rel="alternate"/><published>2023-06-16T13:45:39.575000Z</published><updated>2023-06-16T13:45:39.575000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/5950b0ea93/?limit=25#0ec3/e75c</id><summary type="html">Thanks for the suggestion, I'll definitely check it out. But the fact is that on the 19th version of the firmware from wago everything is in order. Maybe it's the wago firmware?</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/91bdb5b831/?limit=25#895f" rel="alternate"/><published>2023-06-16T06:10:00.541000Z</published><updated>2023-06-16T06:10:00.541000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/91bdb5b831/?limit=25#895f</id><summary type="html">Hello. Faced such a problem that when creating an alarm log, it does not save data. Perhaps you need to install something or specify the path to save? in /etc/CODESYSControl_User.cfg There are lines: [sysfile] PlcLogicPrefix=1 Perhaps you need to specify the path here?</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/5950b0ea93/?limit=25#f7cd" rel="alternate"/><published>2023-06-06T15:12:45.555000Z</published><updated>2023-06-06T15:12:45.555000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/5950b0ea93/?limit=25#f7cd</id><summary type="html">Good afternoon, I encountered such a problem, the PFC200 controller (750-8208) has firmware 03.10.10(22) installed. Before that it was 19. Installed target 4.8.0.0. Codesys SP 19. In the license manager, I can not install, it writes an error. Maybe someone faced such a problem? Thank you.</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/b8e6532abe/?limit=25#2fed/a728" rel="alternate"/><published>2023-04-23T19:53:45.379000Z</published><updated>2023-04-23T19:53:45.379000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/b8e6532abe/?limit=25#2fed/a728</id><summary type="html">It is great! Now everything works! Thank you for your help!</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/b8e6532abe/?limit=25#185c" rel="alternate"/><published>2023-04-23T16:36:48.184000Z</published><updated>2023-04-23T16:36:48.184000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/b8e6532abe/?limit=25#185c</id><summary type="html">If I choose: (udiParameterId := COM.CAA_Parameter_Constants.udiPort, udiValue := 0), I get an error: WRONG_PARAMETER (5005) Or (udiParameterId := COM.CAA_Parameter_Constants.udiPort, udiValue := 1), I get an error: ERROR_UNKNOWN (5004) Which port should be opened? I think the problem is in the port number. Right I think?</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/3a192357bb/?limit=25#35a5" rel="alternate"/><published>2023-04-23T15:54:00.176000Z</published><updated>2023-04-23T15:54:00.176000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/3a192357bb/?limit=25#35a5</id><summary type="html">Thanks a lot! Now everything works! It remains to deal with USB - Com port.</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/3a192357bb/?limit=25#97dc" rel="alternate"/><published>2023-04-23T07:58:10.330000Z</published><updated>2023-04-23T07:58:10.330000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/3a192357bb/?limit=25#97dc</id><summary type="html">I have already tried different options, here is a screenshot of the program and file settings, in response I see result = 1. What could this mean? Target version 4.7.0.0 CS SP18 P4. The visualization and the code itself work, the only problem is getting the temperature request command.</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/3a192357bb/?limit=25#7b58" rel="alternate"/><published>2023-04-22T13:38:57.798000Z</published><updated>2023-04-22T13:38:57.798000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/3a192357bb/?limit=25#7b58</id><summary type="html">CS 18 SP 4 target 4.7.0.0 this method does not work, I tried to download it as root, the result was unsuccessful. Can't get temperature. It seems to me that after version 4.3.0.0 you changed something and this something breaks the system.</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/1ddc279005/?limit=25#30cb" rel="alternate"/><published>2023-04-22T13:35:39.834000Z</published><updated>2023-04-22T13:35:39.834000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/1ddc279005/?limit=25#30cb</id><summary type="html">tried on version CS 18 SP4 with targeter 4.7.0.0?</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/b8e6532abe/?limit=25#f535/fc3e" rel="alternate"/><published>2023-04-21T07:24:13.252000Z</published><updated>2023-04-21T07:24:13.252000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/b8e6532abe/?limit=25#f535/fc3e</id><summary type="html">Could it be a file permission issue? Does the CODESYSControl_User file need sudo rights?</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/b8e6532abe/?limit=25#6400" rel="alternate"/><published>2023-04-13T14:30:48.842000Z</published><updated>2023-04-13T14:30:48.842000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/b8e6532abe/?limit=25#6400</id><summary type="html">cuteCom sees the device and transmits the data.</summary></entry><entry><title>tomas111 modified a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/b8e6532abe/?limit=25#f010" rel="alternate"/><published>2023-04-13T14:28:15.115000Z</published><updated>2023-04-13T14:28:15.115000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/b8e6532abe/?limit=25#f010</id><summary type="html">Deleted all settings, made such settings for com port '1', error ERROR_UNKNOWN 5004. MyComOpen : COM.Open; aParamsB115200 : ARRAY [1..7] OF COM.PARAMETER := (udiParameterId := COM.CAA_Parameter_Constants.udiPort, udiValue := 1), (udiParameterId := COM.CAA_Parameter_Constants.udiBaudrate, udiValue := 115200), (udiParameterId := COM.CAA_Parameter_Constants.udiParity, udiValue := COM.PARITY.NONE), (udiParameterId := COM.CAA_Parameter_Constants.udiStopBits, udiValue := COM.STOPBIT.ONESTOPBIT), (udiParameterId...</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/b8e6532abe/?limit=25#f010" rel="alternate"/><published>2023-04-13T14:26:40.255000Z</published><updated>2023-04-13T14:26:40.255000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/b8e6532abe/?limit=25#f010</id><summary type="html">Deleted all settings, made such settings for com port '1', error ERROR_UNKNOWN 5004. MyComOpen : COM.Open; aParamsB115200 : ARRAY [1..7] OF COM.PARAMETER := (udiParameterId := COM.CAA_Parameter_Constants.udiPort, udiValue := 1), (udiParameterId := COM.CAA_Parameter_Constants.udiBaudrate, udiValue := 115200), (udiParameterId := COM.CAA_Parameter_Constants.udiParity, udiValue := COM.PARITY.NONE), (udiParameterId := COM.CAA_Parameter_Constants.udiStopBits, udiValue := COM.STOPBIT.ONESTOPBIT), (udiParameterId...</summary></entry><entry><title>tomas111 modified a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/b8e6532abe/?limit=25#71e5" rel="alternate"/><published>2023-04-13T09:06:55.568000Z</published><updated>2023-04-13T09:06:55.568000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/b8e6532abe/?limit=25#71e5</id><summary type="html">good afternoon, I edited the settings file, but when I open it, an error pops up, maybe I'm not opening the port correctly? Attached are files with settings.</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/b8e6532abe/?limit=25#71e5" rel="alternate"/><published>2023-04-13T09:05:27.510000Z</published><updated>2023-04-13T09:05:27.510000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/b8e6532abe/?limit=25#71e5</id><summary type="html">good afternoon, I edited the settings file, but when I open it, an error pops up, maybe I'm not opening the port correctly? Attached are files with settings.</summary></entry><entry><title>tomas111 posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/4509211f46/?limit=25#1531/f73d" rel="alternate"/><published>2023-04-05T12:27:52.332000Z</published><updated>2023-04-05T12:27:52.332000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/4509211f46/?limit=25#1531/f73d</id><summary type="html">Installed version 4.7.0.0. This option does not work unfortunately. Maybe there are other options?</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/b8e6532abe/?limit=25#ad67" rel="alternate"/><published>2023-03-31T13:00:30.298000Z</published><updated>2023-03-31T13:00:30.298000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/b8e6532abe/?limit=25#ad67</id><summary type="html">I have a raspberry pi 4 with a USB cable connected to it (USB to RS232 converter). Can I somehow use it and make data exchange?</summary></entry><entry><title>tomas111 modified a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/4509211f46/?limit=25#7c1c" rel="alternate"/><published>2023-02-08T16:15:17.320000Z</published><updated>2023-02-08T16:15:17.320000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/4509211f46/?limit=25#7c1c</id><summary type="html"/></entry><entry><title>tomas111 posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/4509211f46/?limit=25#7c1c" rel="alternate"/><published>2023-02-08T16:14:54.989000Z</published><updated>2023-02-08T16:14:54.989000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/4509211f46/?limit=25#7c1c</id><summary type="html">4.5.0.0 Do you need 4.7.0.0?</summary></entry><entry><title>tomas111 posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/4509211f46/?limit=25#f98e" rel="alternate"/><published>2023-02-08T16:14:48.080000Z</published><updated>2023-02-08T16:14:48.080000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/4509211f46/?limit=25#f98e</id><summary type="html">4.5.0.0 Do you need 4.7.0.0?</summary></entry><entry><title>tomas111 posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/4509211f46/?limit=25#f8f6" rel="alternate"/><published>2023-02-08T08:30:13.006000Z</published><updated>2023-02-08T08:30:13.006000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/4509211f46/?limit=25#f8f6</id><summary type="html">I did, the result is the same. Does not work...</summary></entry><entry><title>tomas111 modified a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/4509211f46/?limit=25#6a39" rel="alternate"/><published>2023-02-08T07:54:36.335000Z</published><updated>2023-02-08T07:54:36.335000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/4509211f46/?limit=25#6a39</id><summary type="html">Thanks for the example, but I still can't run it. In the application, what does result = 1 show There are also screenshots of configurations in the application.</summary></entry><entry><title>tomas111 posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/4509211f46/?limit=25#6a39" rel="alternate"/><published>2023-02-08T07:48:56.944000Z</published><updated>2023-02-08T07:48:56.944000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/4509211f46/?limit=25#6a39</id><summary type="html">Thanks for the example, but I still can't run it. In the application, what does result = 1 show</summary></entry><entry><title>tomas111 modified a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/4509211f46/?limit=25#27d0" rel="alternate"/><published>2023-02-07T07:48:24.563000Z</published><updated>2023-02-07T07:48:24.563000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/4509211f46/?limit=25#27d0</id><summary type="html">Faced with such a problem that this project does not work on target 4.5.0.0 and new versions of Raspberry Pi OS. In the CODESYSControl_User.cfg file, I inserted [SysProcess] Command=AllowAll Confuses the path that is in the example: command1 : STRING := '/opt/vc/bin/vcgencmd measure_temp'; command2 : STRING := 'cat /proc/cpuinfo';</summary></entry><entry><title>tomas111 posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/4509211f46/?limit=25#27d0" rel="alternate"/><published>2023-02-07T07:47:20.121000Z</published><updated>2023-02-07T07:47:20.121000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/4509211f46/?limit=25#27d0</id><summary type="html">Faced with such a problem that this project does not work on target 4.5.0.0 and new versions of Raspberry Pi OS. In the CODESYSControl_User.cfg file, I inserted [SysProcess] Command=AllowAll</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/1ddc279005/?limit=25#da2e" rel="alternate"/><published>2022-12-03T13:24:09.547000Z</published><updated>2022-12-03T13:24:09.547000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/1ddc279005/?limit=25#da2e</id><summary type="html">I have a general problem with temperature. Raspberry 4. I did everything as in the settings but does not show. Maybe I'm editing the file in the wrong way?</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/3a192357bb/?limit=25#6248" rel="alternate"/><published>2022-12-02T12:13:21.986000Z</published><updated>2022-12-02T12:13:21.986000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/3a192357bb/?limit=25#6248</id><summary type="html">On target 4.5.0.0 and raspberry PI4 does not work. Maybe you need to apply the new versions in a different way?</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/1ddc279005/?limit=25#26d9" rel="alternate"/><published>2022-12-02T09:28:36.259000Z</published><updated>2022-12-02T09:28:36.259000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/1ddc279005/?limit=25#26d9</id><summary type="html">Did you manage to solve the issue?</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/04361f89ec/?limit=25#8549/a8f2" rel="alternate"/><published>2022-12-02T09:24:50.123000Z</published><updated>2022-12-02T09:24:50.123000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/04361f89ec/?limit=25#8549/a8f2</id><summary type="html">I noticed that this view does not work on new versions. I have a target of 4.5.0.0. I can't get the temperature</summary></entry><entry><title>tomas111 posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/e267491f66/?limit=25#8a91" rel="alternate"/><published>2022-09-21T11:56:26.194000Z</published><updated>2022-09-21T11:56:26.194000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/e267491f66/?limit=25#8a91</id><summary type="html">Tell me who has encountered, CAN and ProfiBus ports are available on the wago 8208 PLC, how can they be used? Or are they not available?</summary></entry><entry><title>tomas111 posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/e05b750a56/?limit=25#b486/1b82" rel="alternate"/><published>2022-09-21T09:29:17.784000Z</published><updated>2022-09-21T09:29:17.784000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/e05b750a56/?limit=25#b486/1b82</id><summary type="html">Thanks, I did. But my question is why is the data being transmitted for so long? The yikl of the program is 200 ms, but I see that the FB processes the sending for a very long time. I get sending in the region of 1 second between messages.</summary></entry><entry><title>tomas111 posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/e05b750a56/?limit=25#be25" rel="alternate"/><published>2022-09-16T09:39:07.543000Z</published><updated>2022-09-16T09:39:07.543000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/e05b750a56/?limit=25#be25</id><summary type="html">Good afternoon, I ran into such a problem. Wago 8208 installed Codesys Control PFC200 4.5.0.0 I'm trying to use the Com port that he has. I use the COM library.Open and COM.Write. When sending the message, error: HANDLE_INVALID Code: PROGRAM PLC_PRG VAR MyComOpen : COM.Open; aParamsB115200 : ARRAY [1..7] OF COM.PARAMETER := (udiParameterId := COM.CAA_Parameter_Constants.udiPort, udiValue := 0), (udiParameterId := COM.CAA_Parameter_Constants.udiBaudrate, udiValue := 115200), (udiParameterId := COM.CAA_Parameter_Constants.udiParity,...</summary></entry><entry><title>tomas111 posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/2d51cbf534/?limit=25#7a69/e54c/fb10/d705/5dac" rel="alternate"/><published>2022-09-15T13:01:59.041000Z</published><updated>2022-09-15T13:01:59.041000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/2d51cbf534/?limit=25#7a69/e54c/fb10/d705/5dac</id><summary type="html">Good instructions, did everything according to the points. I never saw an OPC with a password... Probably did it wrong at some stage.</summary></entry><entry><title>tomas111 posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/2d51cbf534/?limit=25#7a69/e54c/fb10/d705/ed80" rel="alternate"/><published>2022-09-13T19:17:02.339000Z</published><updated>2022-09-13T19:17:02.339000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/2d51cbf534/?limit=25#7a69/e54c/fb10/d705/ed80</id><summary type="html">Apparently this is exactly it! Thanks!</summary></entry><entry><title>tomas111 posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/2d51cbf534/?limit=25#7a69/e54c/fb10" rel="alternate"/><published>2022-09-13T19:01:15.034000Z</published><updated>2022-09-13T19:01:15.034000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/2d51cbf534/?limit=25#7a69/e54c/fb10</id><summary type="html">Thanks! Everything worked! Now the question is how to make an OPC with a password? Is there such a setting?</summary></entry><entry><title>tomas111 posted a comment on discussion Engineering 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Engineering/thread/2d51cbf534/?limit=25#7a69" rel="alternate"/><published>2022-09-09T13:59:05.395000Z</published><updated>2022-09-09T13:59:05.395000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Engineering/thread/2d51cbf534/?limit=25#7a69</id><summary type="html">I have a raspberry with Rasp OS latest version (April). target codesys 4.5.0.0 Projects are working and the program loading is also working, I can see the visualization. I can't configure OPC UA. Whatever I do OPC UA did not appear in the search for OPC UA Expert. CODESYS V3.5 SP18 Patch 2 is installed. Tell me what's the matter? Maybe someone has faced a similar problem?</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/d2caaa3c86/?limit=25#c6f1/d2c3" rel="alternate"/><published>2022-09-09T11:52:05.011000Z</published><updated>2022-09-09T11:52:05.011000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/d2caaa3c86/?limit=25#c6f1/d2c3</id><summary type="html">What is it about? About the eCocopit platform ? Or codesys control PFC200 SL ?</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/de2957bc1f/?limit=25#ecf0/fedb" rel="alternate"/><published>2022-09-01T16:41:00.516000Z</published><updated>2022-09-01T16:41:00.516000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/de2957bc1f/?limit=25#ecf0/fedb</id><summary type="html">Tell me have you used RS interfaces?</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/de2957bc1f/?limit=25#cdb7" rel="alternate"/><published>2022-09-01T16:32:00.775000Z</published><updated>2022-09-01T16:32:00.775000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/de2957bc1f/?limit=25#cdb7</id><summary type="html">The fact is that if I add a symbolic configuration, I immediately have a bunch of errors, and accordingly it does not compile.</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/de2957bc1f/?limit=25#74c0" rel="alternate"/><published>2022-08-19T10:06:55.401000Z</published><updated>2022-08-19T10:06:55.401000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/de2957bc1f/?limit=25#74c0</id><summary type="html">Good afternoon, who has encountered how in PFC200 - Work with the COM port and choose the mode (232 or 485) - Does OPC UA from codesys work? - The demo version in 4.5.0.0 of the LED control does not work for me, writes an error accessing the library.</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/d2caaa3c86/?limit=25#619f" rel="alternate"/><published>2022-08-18T09:53:48.911000Z</published><updated>2022-08-18T09:53:48.911000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/d2caaa3c86/?limit=25#619f</id><summary type="html">I installed the package, but I can't find the built-in modules, CAN and RS485, are they not supported?</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/d2caaa3c86/?limit=25#3bd2/ef3c" rel="alternate"/><published>2022-08-18T09:31:06.346000Z</published><updated>2022-08-18T09:31:06.346000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/d2caaa3c86/?limit=25#3bd2/ef3c</id><summary type="html">In the test use mode, it is impossible for 15-30 days? If everything suits me, I'll buy it.</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/d2caaa3c86/?limit=25#6aa9" rel="alternate"/><published>2022-08-16T22:04:06.838000Z</published><updated>2022-08-16T22:04:06.838000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/d2caaa3c86/?limit=25#6aa9</id><summary type="html">I don't have this folder, how do I find it or download it?</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/b5d5d27880/?limit=25#69a4" rel="alternate"/><published>2021-10-27T14:40:28.981000Z</published><updated>2021-10-27T14:40:28.981000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/b5d5d27880/?limit=25#69a4</id><summary type="html">I do not quite understand, the temperature is visible in the browser or not? I launched everything as I wrote, but I did not see the result. What am I doing wrong?</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/b5d5d27880/?limit=25#468c" rel="alternate"/><published>2021-10-15T07:26:01.929000Z</published><updated>2021-10-15T07:26:01.929000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/b5d5d27880/?limit=25#468c</id><summary type="html">Thanks, I'll try! But when you start the script somehow you need to call automatically how to do it?</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/b5d5d27880/?limit=25#a4f8" rel="alternate"/><published>2021-09-30T12:51:57.681000Z</published><updated>2021-09-30T12:51:57.681000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/b5d5d27880/?limit=25#a4f8</id><summary type="html">Hi. Not as I can not figure out with I2C. Found another way to obtain data via I2C. Performed everything according to the instructions: https://github.com/hendrychjan/valt-rpi. Now I see in the console: PI @ Raspberrypi: ~ $ Python3 Sensor.py Temperature: 27.42578125 ° C How can I see this line from the console in Codesys? Thanks.</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/49b0381ac1/?limit=25#9a03" rel="alternate"/><published>2021-09-29T08:32:05.261000Z</published><updated>2021-09-29T08:32:05.261000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/49b0381ac1/?limit=25#9a03</id><summary type="html">Hi. Tell me where you can read about the commands that send from Codesys in Raspberry ?</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/3587cc26ee/?limit=25#0d1c" rel="alternate"/><published>2021-09-27T11:18:53.983000Z</published><updated>2021-09-27T11:18:53.983000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/3587cc26ee/?limit=25#0d1c</id><summary type="html">I wanted to read all bytes using the i2C_Master.Read method. I could not get. On the I2C devices tab, I see at the beginning of the address -1 after the i2c_master.read method is performed in the address changed. The variable from the bytes is 0, then the bytes are not received. What to do? How to get bytes?</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/41b936a1b6/?limit=25#3968/6b10" rel="alternate"/><published>2021-09-27T10:46:37.250000Z</published><updated>2021-09-27T10:46:37.250000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/41b936a1b6/?limit=25#3968/6b10</id><summary type="html">Hi, why not an example with I2C?</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/41b936a1b6/?limit=25#1bd8/87b0" rel="alternate"/><published>2021-09-27T10:45:52.309000Z</published><updated>2021-09-27T10:45:52.309000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/41b936a1b6/?limit=25#1bd8/87b0</id><summary type="html">Hi, did you see bytes?</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/3587cc26ee/?limit=25#9f53" rel="alternate"/><published>2021-09-24T13:58:17.801000Z</published><updated>2021-09-24T13:58:17.801000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/3587cc26ee/?limit=25#9f53</id><summary type="html">I want to receive data in Codesys on I2C, I didn't find examples. Tell me there is info how to get data? Data in the Raspberry itself through the console I see. But how to see bytes in Codesys?</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/3a192357bb/?limit=25#12c1" rel="alternate"/><published>2021-09-21T19:04:18.740000Z</published><updated>2021-09-21T19:04:18.740000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/3a192357bb/?limit=25#12c1</id><summary type="html">Thanks! Saw everything! Excellent example. It is a pity in the project description there is no description that it is to write in codesyscontrol_usr.cfg</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/3a192357bb/?limit=25#93ab" rel="alternate"/><published>2021-09-21T18:09:01.414000Z</published><updated>2021-09-21T18:09:01.414000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/3a192357bb/?limit=25#93ab</id><summary type="html">I went over the link. The project did not find. Links do not pass As I understood the whole thing in the sysprocessexecutecommand2 function. Using it, you can call commands?</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/3a192357bb/?limit=25#2192" rel="alternate"/><published>2021-09-21T17:54:34.599000Z</published><updated>2021-09-21T17:54:34.599000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/3a192357bb/?limit=25#2192</id><summary type="html">Thanks! After clicking on the link I did not find the instruction. Can you describe in more detail?</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/3a192357bb/?limit=25#c638" rel="alternate"/><published>2021-09-21T12:25:52.317000Z</published><updated>2021-09-21T12:25:52.317000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/3a192357bb/?limit=25#c638</id><summary type="html">I want to measure and see the processor temperature in Codesys code. Tell me how to do it? Command request comes to the mind in SSH -VcGencmd Measure_Temp But I do not know whether you can call such commands from Codesys? Maybe there is an alternative way measuring temperature? Thanks.</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/02ad361df1/?limit=25#222f" rel="alternate"/><published>2021-09-20T19:59:08.905000Z</published><updated>2021-09-20T19:59:08.905000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/02ad361df1/?limit=25#222f</id><summary type="html">These examples will accurately work on Raspberry PI 3?</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/02ad361df1/?limit=25#53bc" rel="alternate"/><published>2021-09-20T19:50:56.742000Z</published><updated>2021-09-20T19:50:56.742000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/02ad361df1/?limit=25#53bc</id><summary type="html">Thanks. I'm going to try now!</summary></entry><entry><title>tomas111 posted a comment on discussion Runtime 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/Runtime/thread/02ad361df1/?limit=25#1a53" rel="alternate"/><published>2021-09-20T14:51:14.861000Z</published><updated>2021-09-20T14:51:14.861000Z</updated><author><name>tomas111</name><uri>https://forge.codesys.com/u/tomas111/profile/</uri></author><id>https://forge.codesys.com/forge/talk/Runtime/thread/02ad361df1/?limit=25#1a53</id><summary type="html">Good afternoon, tell me how can I from Codesys use the serial port on Raspberry?</summary></entry></feed>