<?xml version="1.0" encoding="utf-8"?>
<feed xml:lang="en" xmlns="http://www.w3.org/2005/Atom"><title>Activity for valeria</title><link href="https://forge.codesys.com/u/valeria/activity/" rel="alternate"/><id>https://forge.codesys.com/u/valeria/activity/</id><updated>2021-07-22T10:02:23.562000Z</updated><subtitle>Recent activity for valeria</subtitle><entry><title>valeria posted a comment on discussion Codesys V2.3 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/CODESYS-V2/thread/c56d799450/?limit=25#82f3" rel="alternate"/><published>2021-07-22T10:02:23.562000Z</published><updated>2021-07-22T10:02:23.562000Z</updated><author><name>valeria</name><uri>https://forge.codesys.com/u/valeria/profile/</uri></author><id>https://forge.codesys.com/forge/talk/CODESYS-V2/thread/c56d799450/?limit=25#82f3</id><summary type="html">Hello, I am working with a (real) PLC which accept (so far) only the CODESYS V3.5 SP14 Patch 3 version and need to use ModbusFB library. The version I have found is the ModbusFB 3.5.17.0 (3S – Smart Software Solution GmbH) which looks to be a too recent version to fit in the CODESYS V3.5 SP14 Patch version. Does any way to get a ModbusFB library which would fit the CODESYS V3.5 SP14 Patch version?</summary></entry><entry><title>valeria modified a comment on discussion Codesys V2.3 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/CODESYS-V2/thread/c39cb4cb5e/?limit=25#4623" rel="alternate"/><published>2021-07-21T11:38:54.002000Z</published><updated>2021-07-21T11:38:54.002000Z</updated><author><name>valeria</name><uri>https://forge.codesys.com/u/valeria/profile/</uri></author><id>https://forge.codesys.com/forge/talk/CODESYS-V2/thread/c39cb4cb5e/?limit=25#4623</id><summary type="html">Again, thanks for the link. I had a look at this example, understood the global idea and made a super very simple test : instance one object "clientTcp: ModbusFB.ClientTcp;" The library ModbusFB was download "automatically" via Library Manager. When I instance the object "clientTcp: ModbusFB.ClientTcp;" , I have no red underlined and when I compile the code get a bunch of errors relative to the ModbusFB library. For example "Unknown type: SysComSettings" and when I look through the ModbusFB library...</summary></entry><entry><title>valeria posted a comment on discussion Codesys V2.3 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/CODESYS-V2/thread/c39cb4cb5e/?limit=25#4623" rel="alternate"/><published>2021-07-21T11:37:31.315000Z</published><updated>2021-07-21T11:37:31.315000Z</updated><author><name>valeria</name><uri>https://forge.codesys.com/u/valeria/profile/</uri></author><id>https://forge.codesys.com/forge/talk/CODESYS-V2/thread/c39cb4cb5e/?limit=25#4623</id><summary type="html">Again, thanks for the link. I had a look at this example, understood the global idea and made a super very simple test : instance one object "clientTcp: ModbusFB.ClientTcp;" The library ModbusFB was download "automatically" via Library Manager. When I instance the object "clientTcp: ModbusFB.ClientTcp;" , I have no red underlined and when I compile the code get a bunch of errors relative to the ModbusFB library. For example "Unknown type: SysComSettings" and when I look through the ModbusFB library...</summary></entry><entry><title>valeria posted a comment on discussion Codesys V2.3 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/CODESYS-V2/thread/c39cb4cb5e/?limit=25#f47d" rel="alternate"/><published>2021-07-20T13:12:16.651000Z</published><updated>2021-07-20T13:12:16.651000Z</updated><author><name>valeria</name><uri>https://forge.codesys.com/u/valeria/profile/</uri></author><id>https://forge.codesys.com/forge/talk/CODESYS-V2/thread/c39cb4cb5e/?limit=25#f47d</id><summary type="html">Wow! Sound good :) I have a look. Thanks</summary></entry><entry><title>valeria modified a comment on discussion Codesys V2.3 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/CODESYS-V2/thread/c39cb4cb5e/?limit=25#ae1a" rel="alternate"/><published>2021-07-20T11:57:23.563000Z</published><updated>2021-07-20T11:57:23.563000Z</updated><author><name>valeria</name><uri>https://forge.codesys.com/u/valeria/profile/</uri></author><id>https://forge.codesys.com/forge/talk/CODESYS-V2/thread/c39cb4cb5e/?limit=25#ae1a</id><summary type="html">I'm new in Codesys. I have to communicate with a large number of remote Modbus slave. For this I would like to create an "object" (FB or others... whatever) MBslave and instantiate it several times. I can realize this graphically (in the device tree in codesys) by creating under "Ethernet" a "Modbus_Master" module and then under that create all the Modbus_Slave modules. But for reasons of maintenance I want to realize this "by hand". Is this possible? I have already declared variables of type "ModbusTCPSlave"...</summary></entry><entry><title>valeria posted a comment on discussion Codesys V2.3 🇬🇧</title><link href="https://forge.codesys.com/forge/talk/CODESYS-V2/thread/c39cb4cb5e/?limit=25#ae1a" rel="alternate"/><published>2021-07-20T11:30:05.083000Z</published><updated>2021-07-20T11:30:05.083000Z</updated><author><name>valeria</name><uri>https://forge.codesys.com/u/valeria/profile/</uri></author><id>https://forge.codesys.com/forge/talk/CODESYS-V2/thread/c39cb4cb5e/?limit=25#ae1a</id><summary type="html">I'm new in Codesys. I have to communicate with a large number of remote Modbus slave. For this I would like to create an "object" (FB or others... whatever) MBslave and instantiate it several times. I can realize this graphically (left tab in codesys) by creating under "Ethernet" a "Modbus_Master" module and then under that create all the Modbus_Slave modules. But for reasons of maintenance I want to realize this "by hand". Is this possible? I have already declared variables of type "ModbusTCPSlave"...</summary></entry></feed>