(no subject) shota wiki (Thread)
Last updated: 2025-02-20

Post by secundino on License CODESYS Forge talk (Post)
Good morning, I need to activate a CODESYS license on your website, as the computer where it was originally installed has been formatted. I have already sent two emails to store-support@codesys.com, but I have not received a response yet. Could you please assist me with this issue as soon as possible?
Last updated: 2025-02-20

Home shota wiki (WikiPage)
Project Members: shota (admin)
Last updated: 2025-02-20

Post by dkugler on SP20 Visualization Element Dynamic Colors CODESYS Forge talk (Post)
check the filter settings at properties menue bar and select "all categories" good luck1
Last updated: 2025-02-20

SP20 Visualization Element Dynamic Colors CODESYS Forge talk (Thread)
SP20 Visualization Element Dynamic Colors
Last updated: 2025-02-20

Home (version 1) discussion vkira wiki (Thread)
Home (version 1) discussion
Last updated: 2025-02-20

Post by secundino on License CODESYS Forge talk (Post)
Good morning, I need to activate a CODESYS license on your website, as the computer where it was originally installed has been formatted. I have already sent two emails to store-support@codesys.com, but I have not received a response yet. Could you please assist me with this issue as soon as possible?
Last updated: 2025-02-20

License CODESYS Forge talk (Thread)
License
Last updated: 2025-02-20

Redundancy for RTE x64 - stuck in standalone CODESYS Forge talk (Thread)
Redundancy for RTE x64 - stuck in standalone
Last updated: 2025-02-20

wiki Discussion tmarmy1 wiki (Discussion)
Forum for wiki comments
Last updated: 2025-02-20

blog Discussion tmarmy1 blog (Discussion)
Forum for blog comments
Last updated: 2025-02-20

(no subject) tmarmy1 wiki (Thread)
Last updated: 2025-02-20

Home tmarmy1 wiki (WikiPage)
Project Members: tmarmy1 (admin)
Last updated: 2025-02-20

Post by tmarmy1 on Redundancy for RTE x64 - stuck in standalone CODESYS Forge talk (Post)
Sorry if this has been asked before, but I can't seem to locate a thread that leads me answers. I am running two RTE x64 softPLCs, one on the host machine and a second via a VM. I have managed to finally get both to a position that they see each other, but they are in standalone mode instead of an active/passive state for failover (image attached). Every attempt to sync via the button fails. There is probably some step or option that I have missed in my bumbling through this learning process, but for the life of me I can't seem to figure it out. Anyone got any suggestions what I need to look at to get this into an active/passive redundancy state?
Last updated: 2025-02-20

Post by george32 on TCP Server CODESYS Forge talk (Post)
Thank you for your advice Rinie, I have tried to follow this example but found one problem.When I disconnect with Hercules the system does not acknowledge the lost of its connection this could result in critical errors. Because of this error I am trying to implement the Syssocket library. With this library I am having a problem which I could not solve. I have the following code: ip_adres : STRING :='0.0.0.0'; port : WORD := 5000; iStep : INT := 1; // Socket information Socket_handler : SysSocket_Interfaces.RTS_IEC_HANDLE; Socket_handler_result : SysSocket_Interfaces.RTS_IEC_RESULT; Socket_adress : SysSocket_Interfaces.SOCKADDRESS; Addres_Convert : SysSocket_Implementation.RTS_IEC_RESULT; // Bind information Bind_handler : SysSocket_Interfaces.RTS_IEC_RESULT; // Listener Information Listener_handler : SysSocket_Interfaces.RTS_IEC_RESULT; Addres_Convert := SysSocket_Implementation.SysSockInetAddr(szIPAddress:= ip_adres,pInAddr:= ADR(Socket_adress.sin_addr)); Socket_adress.sin_family:= SysSocket_Interfaces.SOCKET_AF_INET; Socket_adress.sin_port := SysSocket_Implementation.SysSockHtons(usHost:= port); CASE iStep OF 1: // Create Socket Socket_handler :=SysSockCreate( iAddressFamily :=SysSocket_Interfaces.SOCKET_AF_INET, diType:=SysSocket_Interfaces.SOCKET_STREAM, diProtocol:=SysSocket_Interfaces.SOCKET_IPPROTO_TCP, pResult:=ADR(Socket_handler_result)); IF Socket_handler = SysSocket_Interfaces.RTS_INVALID_HANDLE THEN iStep := 1; ELSE iStep := 2; END_IF 2: Bind_handler := SysSocket_Implementation.SysSockBind( hSocket:=Socket_handler, pSockAddr :=ADR(Socket_adress), diSockAddrSize:=SIZEOF(Socket_adress) ); 3: Listener_handler := SysSocket_Implementation.SysSockListen( hSocket :=Socket_handler, diMaxConnections :=1); END_CASE When I am trying to get this working, the SysSockBind function gives a value of 16#207 which means adress already in use. I find this weird because of the IP-adress of 0.0.0.0. I think I am converting the Ip-adress in the wrong way, but the code does not give a error arround this. So therefore I cannot find the solution to this problem. I hope someone could help me with this problem. Thanks in advance George
Last updated: 2025-02-20

wiki Discussion clarenced wiki (Discussion)
Forum for wiki comments
Last updated: 2025-02-20

blog Discussion clarenced blog (Discussion)
Forum for blog comments
Last updated: 2025-02-20

(no subject) clarenced wiki (Thread)
Last updated: 2025-02-20

Post by clarenced on Multiple applications on one device sharing variables. CODESYS Forge talk (Post)
I am looking for an example of how to run 2 applications on 1 device that would have global variables shared between the two apps. In this case what I am trying to do is to have the main program logic run as one application and then have the visualization run as a second application. I find this https://us.store.codesys.com/media/n98_media_assets/files/000013-F/0/Multiple%20Applications_en.pdf, that talks about exactly what I want to do, but I can't find the download. The main reason I want to do this is for download speed. Right now it takes at least a minute to download our application to the PLC. A simple program downloads to the PLC in a very short time, but add visualization and the download time gets much longer. If I could download the program separately from the visualization I think that a simple program change would take very little time to download. I have tried create a GVL in the POUs view. This partly works in that both applications can see the GVL, but they each create their own instance of it and the variables are not shared between the two apps. There are ideas of using OPCUA but this raises problems with licensing and having to move any variable that needs to be shared into the Symbol Configuration. This adds a lot of management to keep this up to date. Any ideas would be appreciated thanks.
Last updated: 2025-02-20

Home clarenced wiki (WikiPage)
Project Members: clarenced (admin)
Last updated: 2025-02-20

Post by eschwellinger on License CODESYS Forge talk (Post)
could not see your request...
Last updated: 2025-02-20

Post by ojz0r on Multiple applications on one device sharing variables. CODESYS Forge talk (Post)
One thing you could do is create an object with the variable as field with a function and procedure to get the variable (read) and set the variable (write). These are then called from your program and the vizualization.
Last updated: 2025-02-20

Post by clarenced on Multiple applications on one device sharing variables. CODESYS Forge talk (Post)
Sounds feasible, but how would I create this object so that both applications would use the same instance of it. If this did work, it's still not really the solution I am looking for as it would mean mapping every variable I want to use on the hmi through this object vs I was hopping all the GVL variables would be available.