Search Project: *:*

 
<< < 1 .. 2332 2333 2334 2335 2336 .. 3702 > >> (Page 2334 of 3702)

Change IO-Link Device Interface connected to a Profinet-Slave at Runtime CODESYS Forge talk (Thread)
Change IO-Link Device Interface connected to a Profinet-Slave at Runtime
Last updated: 2025-03-19

Post by atone on Set DeviceID of an IO-Link Sensor at Runtime CODESYS Forge talk (Post)
I need to be able to change (set) the DeviceID of an IO-Link sensor (see DeviceID.png) at runtime. I tried with both ProfinetCommon.PN_PortConfiguration and ProfinetCommon.IOL_PortConfiguration, but I get an error for both when I try to read the port configuration (see PN_PortConfiguration.png). Does one of those FBs is the right one for my purpose? Do I possibly make a mistake when assigning the parameter IOLD_ID/IOLM_ID?
Last updated: 2025-03-19

Post by otbeka on CAA File Handling: "Read only" error CODESYS Forge talk (Post)
Hi, On CODESYS V3.5.19.50 I am using the latest 3S File Access library (CAA File & CAA Types) to save and retrieve configuration data from the User Data section of an SD card, via file called config.txt. The application reads the file to memory once upon initialisation, and then the only other operation is overwriting the file with the updated configuration whenever the user changes the settings. An issue is ocurring, seemingly randomly, where the config.txt file, and all surrounding directories, cannot be written to by the unit, returning a READ_ONLY_CAA error upon file open. This sometimes does not clear even after power-cycling the PLC several times, yet checking the file permissions with ls -l shows normal read, write, and execute access. I am wondering if this is caused by the PLC itself or by an issue in my application. I have included my CAA File handler function block (SD_Card_Bin(FB).txt) and any associated types/calls below: TYPE ConfigData : STRUCT Config : ARRAY[0..256] OF STRING(64); NumberOfStrings : UDINT; END_STRUCT END_TYPE TYPE Buffer : STRUCT Data : ARRAY[0..SIZEOF(ConfigData)] OF BYTE; DataLength : UDINT; END_STRUCT END_TYPE A case within my MAIN PRG: mode.WriteConfigDataToFile: VisuElems.CURRENTVISU := 'Screen_Write'; IF xModeHasChanged THEN iErrorCount := 0; iRoute := 0; END_IF CASE iRoute OF 0: inBuffer := ConfigData_To_Buffer(GVL.UnitData); xConfigError := FALSE; xDataConfigured := FALSE; iRoute := 1; 1 : //Read Data from Card SD_Card_Bin.strFileName :=FileName; SD_Card_Bin.iFileOperation := 2; SD_Card_Bin(xExecute :=TRUE, WriteBuffer := inBuffer, xDone =>xDataConfigured, xError=>xConfigError, strErrorCodes=>strError); IF xDataConfigured THEN SD_Card_Bin(xExecute :=FALSE); IF xConfigError THEN iRoute := 32767; ELSE iRoute :=100; END_IF END_IF 100: // The end bCurMode := mode.DisplayProcessVariables; 32767: // Config error iErrorCount := iErrorCount + 1; IF iErrorCount > 2 THEN // Repeats 3 times, if no progress abandons and returns error bCurMode := mode.WriteError; ELSE iRoute := 0; // Try again END_IF END_CASE I'd like to rule out my application as the cause of this bug - help via comments or criticism would be greatly appreciated.
Last updated: 2025-03-19

Post by peterkcontrols on Codesys Network driver install for Codesys Control RTE x64 CODESYS Forge talk (Post)
Resolved this. There is a config file called CodesysControl_User that I had to edit to set the driver to component 5. I deleted the semi colon next to Component.5=CmpEt1000Drv
Last updated: 2025-03-19

Professional Developer Edition (git): Invalid URI CODESYS Forge talk (Thread)
Professional Developer Edition (git): Invalid URI
Last updated: 2025-03-19

wiki Discussion r-c-r wiki (Discussion)
Forum for wiki comments
Last updated: 2025-03-19

blog Discussion r-c-r blog (Discussion)
Forum for blog comments
Last updated: 2025-03-19

(no subject) r-c-r wiki (Thread)
Last updated: 2025-03-19

Home r-c-r wiki (WikiPage)
Project Members: r-c-r (admin)
Last updated: 2025-03-19

Post by r-c-r on SM3RaspiStepper 0.0.0.6 issue CODESYS Forge talk (Post)
Hello, I noticed that version 0.0.0.6 is now available, so I tested it using CODESYS V3.5 SP19 Patch 7 and SoftMotion 4.17.0.0. While the project compiles and downloads without issues, I encountered a problem with the 'Enable: GPIO pin number that is set when the axis is enabled (with MC_Power) (0: not used)' functionality — it no longer works (HIGH level not present at the output pin). I observed the same behavior with version 0.0.0.5, whereas version 0.0.0.4 functions correctly. Could you help me identify what might be causing this issue or suggest how to resolve it? Thanks.
Last updated: 2025-03-19

blog Discussion lacypaige blog (Discussion)
Forum for blog comments
Last updated: 2025-03-19

wiki Discussion lacypaige wiki (Discussion)
Forum for wiki comments
Last updated: 2025-03-19

(no subject) lacypaige wiki (Thread)
Last updated: 2025-03-19

Home lacypaige wiki (WikiPage)
Project Members: lacypaige (admin)
Last updated: 2025-03-19

Post by respl on #3 CR711 To EX710 Network Variable Error CODESYS Examples tickets (Post)
Please reply. Attached is the file of wireshark capture during communication.
Last updated: 2025-03-20

(no subject) CODESYS Examples tickets (Thread)
Last updated: 2025-03-20

Ticket #3: CR711 To EX710 Network Variable Error CODESYS Examples tickets (Ticket)
We are connected IFM CR711S to Exor EX710. We are exchanging data using network variables. Both devices are configured on same project so no need to use file source. When tested application it works fine. But after 3 months same application not working. We are able to send data from CR711 to EX710 but data from Ex710 to CR711s works only for one scan when we cold reset CR 711S. Can somebody help to find out error.2025-03-20 03:37:28.624000 Ticket #3: CR711 To EX710 Network Variable Error CODESYS Examples codesys-example tickets tickets False /prj/codesys-example/tickets/3/ Ticket CR711 To EX710 Network Variable Error False 1 2025-03-17 16:59:41.013000 3 CR711 To EX710 Network Variable Error open We are connected IFM CR711S to Exor EX710. We are exchanging data using network variables. Both devices are configured on same project so no need to use file source. When tested application it works fine. But after 3 months same application not working. We are able to send data from CR711 to EX710 but data from Ex710 to CR711s works only for one scan when we cold reset CR 711S. Can somebody help to find out error. False False 0 0 0 None 1.0 respl None
Last updated: 2025-03-20

Codesys Symbolic Access CODESYS Forge talk (Thread)
Codesys Symbolic Access
Last updated: 2025-03-20

Post by respl on Codesys Symbolic Access CODESYS Forge talk (Post)
We need to exchange data between two controller IFM and EXOR. Our one controller support codesys symbolic access while other support COdesys V3 application. can anybody tell me how to do communication between these two. Sample program will be highly appreciable. Regards, Rahul Sayre
Last updated: 2025-03-20

Post by pernockham on Persistence Manager: Config File not found? CODESYS Forge talk (Post)
Back in november I paused this, but wanted to reattempt using the persistent manager, the behavior is still the same. Most "login attempts" s are stopped with the message "One or more errors occurred" but I have no idea what that error might be. The only clue is this message is presented while the lower left status box says "Generating code...: relocation pou". For clarification. Build/Generate code is successful, no errors. Error appears when I try to download/login (physical or simulation) to a device. I did manage to login (in simulation mode) at one point, but then the error message "PersistenceChannel: Config file not found!". And no persistence files were created. I have done device-tree/reset-orgin also clean/clean all etc. Removed/re-inserted persistance manager. Behaviour is just the same. Removing Persistence Manage and everything is working OK. Is there possibly more info somewhere about the "One or more errors occured"-message?
Last updated: 2025-03-20

Post by atone on CAA File Handling: "Read only" error CODESYS Forge talk (Post)
In case of error while opening the file to read you assume that the file doesn't exist and try to create one. But it could be that the SD card is not ready yet or simply not there. I would try to check first if the SD card is there and accessible. Otherwise with FILE.Create you could end up creating a new directory that is not mapped to the SD card. This would explain the errors even after a reboot, though it doesn't explain the READ_ONLY_CAA error I guess? I would use FILE.DirOpen and FILE.DirList to check if the SD card is there and ready.
Last updated: 2025-03-20

wiki Discussion mitboz wiki (Discussion)
Forum for wiki comments
Last updated: 2025-03-20

blog Discussion mitboz blog (Discussion)
Forum for blog comments
Last updated: 2025-03-20

(no subject) mitboz wiki (Thread)
Last updated: 2025-03-20

Home mitboz wiki (WikiPage)
Project Members: mitboz (admin)
Last updated: 2025-03-20

<< < 1 .. 2332 2333 2334 2335 2336 .. 3702 > >> (Page 2334 of 3702)

Showing results of 92530

Sort by relevance or date