wiki Discussion
bitor-leao
wiki
(Discussion)
Forum for wiki comments
Last updated: 2025-11-16
Home
bitor-leao
wiki
(WikiPage)
Project Members: bitor-leao (admin)
Last updated: 2025-11-16
(no subject)
bitor-leao
wiki
(Thread)
Last updated: 2025-11-16
Post by bitor-leao on *EXCEPTION* [ProsessorLoadWatchdog] codesys 3.5.11.40
CODESYS Forge
talk
(Post)
Good night. I am having a problem with CODESYS 3.5.11.40, which gives the exception EXCEPTION [ProcessorLoadWatchdog]. I followed some forum posts and tried to modify the CODESYSControl.cfg file, but it shows: [SysFile] Windows.WorkingDirectory=C:\ProgramData\CODESYS\CODESYSControlWinV3\D5050FE1 Then I go to this directory and try to modify CODESYSControl.cfg according to the forums, but it doesn’t work: [CmpSchedule] ;EnableLogger=0 ProcessorLoad.Maximum=80 ;Timeslicing.Mode=Internal ;Timeslicing.PlcSlicePercent=80 ;Timeslicing.PlcSliceUs=4000 ;Timeslicing.StartOnProcessorLoad=1 ;SchedulerPriority=5 ;SchedulerInterval=1000 I tried to change ProcessorLoad.Maximum to 0 or 100, but it doesn’t compile when I try. I really don’t know what to do,
Last updated: 2025-11-16
Post by bitor-leao on *EXCEPTION* [ProsessorLoadWatchdog] codesys 3.5.11.40
CODESYS Forge
talk
(Post)
Good night. I am having a problem with CODESYS 3.5.11.40, which gives the exception EXCEPTION [ProcessorLoadWatchdog]. I followed some forum posts and tried to modify the CODESYSControl.cfg file, but it shows: [SysFile] Windows.WorkingDirectory=C:\ProgramData\CODESYS\CODESYSControlWinV3\D5050FE1 Then I go to this directory and try to modify CODESYSControl.cfg according to the forums, but it doesn’t work: [CmpSchedule] ;EnableLogger=0 ProcessorLoad.Maximum=80 ;Timeslicing.Mode=Internal ;Timeslicing.PlcSlicePercent=80 ;Timeslicing.PlcSliceUs=4000 ;Timeslicing.StartOnProcessorLoad=1 ;SchedulerPriority=5 ;SchedulerInterval=1000 I tried to change ProcessorLoad.Maximum to 0 or 100, but it doesn’t compile when I try. I really don’t know what to do,
Last updated: 2025-11-16
*EXCEPTION* [ProsessorLoadWatchdog] codesys 3.5.11.40
CODESYS Forge
talk
(Thread)
EXCEPTION [ProsessorLoadWatchdog] codesys 3.5.11.40
Last updated: 2025-11-16
Home (version 1) discussion
sudecetin
wiki
(Thread)
Home (version 1) discussion
Last updated: 2025-11-16
wiki Discussion
ckjosphat
wiki
(Discussion)
Forum for wiki comments
Last updated: 2025-11-16
blog Discussion
ckjosphat
blog
(Discussion)
Forum for blog comments
Last updated: 2025-11-16
(no subject)
ckjosphat
wiki
(Thread)
Last updated: 2025-11-16
Post by adam on Get/Set I/O Address Mapping of DeviceObjects in python Script
CODESYS Forge
talk
(Post)
Found out.Its script engine bug . Update to script engine version 4.2.0.0. and problem solved
Last updated: 2025-11-17
Get/Set I/O Address Mapping of DeviceObjects in python Script
CODESYS Forge
talk
(Thread)
Get/Set I/O Address Mapping of DeviceObjects in python Script
Last updated: 2025-11-17
Home (version 1) discussion
goodving
wiki
(Thread)
Home (version 1) discussion
Last updated: 2025-11-17
Home (version 1) discussion
jongscx
wiki
(Thread)
Home (version 1) discussion
Last updated: 2025-11-17
*EXCEPTION* [ProsessorLoadWatchdog] codesys 3.5.11.40
CODESYS Forge
talk
(Thread)
EXCEPTION [ProsessorLoadWatchdog] codesys 3.5.11.40
Last updated: 2025-11-17
Post by davidbo on RETAIN PERSISTENT only stored at gracefully shutdown?
CODESYS Forge
talk
(Post)
I have {attribute 'checksumnoinit_override' := '2629838988'} {attribute 'init_related_code' := '5c6efcf8-e0f4-4166-a9fa-17eadd8908df'} VAR_GLOBAL RETAIN PERSISTENT {attribute 'order_in_persistent_editor' := '0'} segmentValue: ARRAY[0..49] OF REAL; {attribute 'order_in_persistent_editor' := '1'} segmentTime: ARRAY[0..49] OF REAL; // Generated instance path of persistent variable PRG.test: INT; // Generated instance path of persistent variable PRG.nw_storage: SysSocket_Implementation.SysSocket_Interfaces.SOCK_ADAPTER_INFORMATION2; END_VAR When I have changed PRG.nw_storage it will not be stored at a power off, but if I do a: sudo systemctl restart codesycontrol and then a power off it will be stored. Is there a way to store persistent variables without a restart of codesyscontrol? Can anyone explain how and when CODESYS store persistent variables?
Last updated: 2025-11-17
Post by shaunvdm on OSCAT Scale_r function not working in LD 4.60 works in LAD2 on 3.5.21sp3
CODESYS Forge
talk
(Post)
Hi All, We downgraded Codesys LAD/FB in the IDE to version 4.5 and it works. Codesys Version 4.6 lad/fb not working. Was the way we fixed this. Kind Regards Shaun
Last updated: 2025-11-17
Post by jonasz on Deploy LicenseServer for Linux SL
CODESYS Forge
talk
(Post)
After carefully studying the documentation, I have a question: is a second hardware-independent time source required for the correct operation of the VirtualSafety system?
Last updated: 2025-11-17
wiki Discussion
thongcomnova
wiki
(Discussion)
Forum for wiki comments
Last updated: 2025-11-17
blog Discussion
thongcomnova
blog
(Discussion)
Forum for blog comments
Last updated: 2025-11-17
(no subject)
thongcomnova
wiki
(Thread)
Last updated: 2025-11-17
Post by bruno-roth on 22kW Wallbox mit Modbus
CODESYS Forge
talk
(Post)
Hallo, das ist wohl das falsche Forum für Wallboxen :-) Aber ich empfehle dir Die GO-E-Charger die hat eine sehr offene Schnittstelle und API auch mit Modbus TCP https://github.com/goecharger/go-eCharger-API-v2/blob/main/modbus-de.md
Last updated: 2025-11-17
22kW Wallbox mit Modbus
CODESYS Forge
talk
(Thread)
22kW Wallbox mit Modbus
Last updated: 2025-11-17
Home (version 1) discussion
larboardinner
wiki
(Thread)
Home (version 1) discussion
Last updated: 2025-11-17
Home (version 1) discussion
arekun
wiki
(Thread)
Home (version 1) discussion
Last updated: 2025-11-17