Post by altin on No source code available for this object
CODESYS Forge
talk
(Post)
Hello, I get same error message but pointing at different library. The error appears when im trying to scroll an AlarmTable on a thouch screen (ifm CR1204). Anyone knows what causing this and how to procceed? Many thanks in advance,
Last updated: 2026-02-16
No source code available for this object
CODESYS Forge
talk
(Thread)
No source code available for this object
Last updated: 2026-02-16
Home (version 1) discussion
mohammedben
wiki
(Thread)
Home (version 1) discussion
Last updated: 2026-02-17
Post by pernockham on Unable to deploy "Control for Linux SL 4.18.0.0"
CODESYS Forge
talk
(Post)
Does this cover what you need?
Last updated: 2026-02-17
Post by pernockham on Unable to deploy "Control for Linux SL 4.18.0.0"
CODESYS Forge
talk
(Post)
Am I alone in this? Is this a known fault? Should I look for the reason of the lacking update option for "Control for linux SL" in my system or is it a potential fault in the codesys system?
Last updated: 2026-02-17
Post by eschwellinger on Unable to deploy "Control for Linux SL 4.18.0.0"
CODESYS Forge
talk
(Post)
we need the Systeminformation in the Communication tap(logged in)
Last updated: 2026-02-17
Post by pernockham on Unable to deploy "Control for Linux SL 4.18.0.0"
CODESYS Forge
talk
(Post)
And the strange thing for me is that if i connect with an older IDE version (where I only have 4.17.0.0 installed) I can see both "CODESYS Control for Linux SL" and "CODESYS Edge Gateway for linux". And that I loose (both presence and possibility to update) the first option (Control SL) if i let the updater install "Control for linux SL" vers. 4.18.0.0 or later. (Note that runtime 4.17.0.0 is installed and it is running and I can login to that system, but no apparent option available to update it to 4.19.0.0). Attached print screen where I connected the "deploy sl tool" to the same system, where the upper (IDE) one has 4.19.0.0 installed, while the lower one has 4.17.0.0 installed..
Last updated: 2026-02-17
Power off bit to save last log
CODESYS Forge
talk
(Thread)
Power off bit to save last log
Last updated: 2026-02-17
Post by reinier-geers on Power off bit to save last log
CODESYS Forge
talk
(Post)
3.5.20.4 Is there a power off bit, so i can save my last logfile ?
Last updated: 2026-02-17
Post by eschwellinger on Unable to deploy "Control for Linux SL 4.18.0.0"
CODESYS Forge
talk
(Post)
Hi could you check if this really exists in 4.19.0.0 deploy tool? In your case architecture is missing- see my configuration
Last updated: 2026-02-17
Post by pernockham on Unable to deploy "Control for Linux SL 4.18.0.0"
CODESYS Forge
talk
(Post)
Correct, my Device architecture says "None" is this position. A missing config somewhere?
Last updated: 2026-02-18
wiki Discussion
nehaltrivedi96
wiki
(Discussion)
Forum for wiki comments
Last updated: 2026-02-18
blog Discussion
nehaltrivedi96
blog
(Discussion)
Forum for blog comments
Last updated: 2026-02-18
Home
nehaltrivedi96
wiki
(WikiPage)
Project Members: nehaltrivedi96 (admin)
Last updated: 2026-02-18
(no subject)
nehaltrivedi96
wiki
(Thread)
Last updated: 2026-02-18
Post by nehaltrivedi96 on Modbus connection via Qronox PCD3 M6893
CODESYS Forge
talk
(Post)
Hello, I am currently scaling 4-20mA signals and the scaled output (temperature) has to be sent via modbus protocol to a tool like doctor modbus or modbus poll. I have defined my inputs as real as and the output is also real, but to send this output via modbus it has to be of word. So how will i convert real into word and then send the generated output via modbus?
Last updated: 2026-02-18
Post by risele on Modbus connection via Qronox PCD3 M6893
CODESYS Forge
talk
(Post)
You are welcome. Also note, that it's valid only if you modbus-device use same real/float value representation (IEEE 754). That's true for most of systems. But some devices may have other representation, such as integer + position of the decimal point, for example 123.456 is integer = 123456 and position = 3 Also note, that, ones again, depending on endianess of each system, you may also need to swap not just words, but bytes. TYPE u_Real : UNION rVal:REAL; wVal:ARRAY[0..1] OF WORD; bVal:ARRAY[0..3] OF BYTE; dwVAL:DWORD; //same as previous, may be easier to specify the MB register END_UNION END_TYPE than swapping may be something as VAR A,B,C,D:BYTE; //Bytes of the real value uIn, uOut:u_Real; rVal:REAL; ModbusReg1,ModbusReg2:WORD; END_VAR uIn.rVal:=rVal; uOut.A:=uIn.D; uOut.B:=uIn.C; uOut.C:=uIn.B; uOut.D:=uIn.A; ModbusReg1:=uOut.wVal[0]; ModbusReg1:=uOut.wVal[2]; Or you even need to reorder bits... Ones again, sending float/real values is not defined by Modbus protocol itself, so it is hardware- and software-dependent. The Modbus Poll (and most of modbus tools) have configuration parameters that will properly swap bytes on their side. Ones again, that's very helpful: https://www.scadacore.com/tools/programming-calculators/online-hex-converter/
Last updated: 2026-02-19
Post by risele on Modbus connection via Qronox PCD3 M6893
CODESYS Forge
talk
(Post)
First, if you don't need to change conversion rules in runtime, take a look at "Unit conversion" module (Application -> add object -> UnitConversion). You can specify there biderectional conversion with different units, limits and so on. Second, since MODBUS don't have "real" types but only general 16-bit registers and Real is 32-bit, generally you need a byte-was conversion Real <> two Words. Note, that depending on the devices on both sides, there are two options: Real-> Word1, Word2 or Real-> Word2, Word1, where Word1 is minor register in Modbus register pair and Word2 is major. You can use simple union: TYPE u_Real : UNION rVal:REAL; wVal:ARRAY[0..1] OF WORD; dwVAL:DWORD; //same as previous, may be easier to specify the MB register END_UNION END_TYPE and convert it as following: VAR myUnion:u_Real; rValue_TO_SEND:REAL; rValue_TO_GET:REAL; END_VAR myUnion.rVal:=rValue_TO_SEND; rValue_TO_GET:=myUnion.rVal; Note, that WORD-order should be properly set in MODBUS registers, otherwise you will get strange values. This tool is helpful: https://www.scadacore.com/tools/programming-calculators/online-hex-converter/ Alternative, you can use functions as REAL_TO_DW and DW_TO_REAL from OSCAT_BASIC, for example.
Last updated: 2026-02-19
Post by nehaltrivedi96 on Modbus connection via Qronox PCD3 M6893
CODESYS Forge
talk
(Post)
Thank you for your suggestions, based on it I will modify the code
Last updated: 2026-02-18
Modbus connection via Qronox PCD3 M6893
CODESYS Forge
talk
(Thread)
Modbus connection via Qronox PCD3 M6893
Last updated: 2026-02-19
wiki Discussion
william
wiki
(Discussion)
Forum for wiki comments
Last updated: 2026-02-19
blog Discussion
william
blog
(Discussion)
Forum for blog comments
Last updated: 2026-02-19
(no subject)
william
wiki
(Thread)
Last updated: 2026-02-19