(no subject)
myproject
home
(Thread)
Last updated: 2024-10-22
myproject SVN repository
myproject
code
(SVN Repository)
Last updated: 2024-10-22
Post by trent on Automation server - trends stop recording - need to manually reconnect
CODESYS Forge
talk
(Post)
Hi All, I use the analysis page in automation server to capture historical trends from my PLC - i only sample one point per hour but it does the job (for now) One issue I have is I often log on to analysis page to find the system has stopped recording trends from my PLC. To fix this, I need to choose "state information" in the "List view" under PLC and click "Reconnect" When I do this I see my variables listed under "parameters" under "PLC Details" start updating again and the trend in Data analyzer continues to update. My Question, Why do I need to manually reconnect? Is there a way to get automation server to automatically reconnect to the PLC so I continue to capture data from the PLC? Regards, Trent
Last updated: 2024-10-22
Post by eschwellinger on Ethercat Slave - Load PDO From Device
CODESYS Forge
talk
(Post)
Which CODESYS Version and which EtherCAT Master version?
Last updated: 2024-10-23
code2 Discussion
myproject
code2
(Discussion)
Forum for code2 comments
Last updated: 2024-10-22
Post by daniel on SysFileOpen not working
CODESYS Forge
talk
(Post)
Hello, I have the same problem now with 3.5.20 Patch 3. Normally it works if I ad in CODESYSControl.cfg: [SysFile] ForceIecFilePath=0 (This told me codesys last time) I try to use the placeholders but without success. Something special is that the Files are not in C:. The Plc Configuration Path is not as usual C:\ProgrammData\CODESYS\CODESYSControlRTEV3\, it's E:\Control.
Last updated: 2024-10-23
Post by timvh on TrueType font problem
CODESYS Forge
talk
(Post)
We have also used the Roboto font without any problems, but possibly your company modified it a little bit? Maybe you can try the original ones from Google: https://fonts.google.com/specimen/Roboto
Last updated: 2024-10-23
Post by eschwellinger on Automation server - trends stop recording - need to manually reconnect
CODESYS Forge
talk
(Post)
Could you please check which EdgeGateway Version is up and running?
Last updated: 2024-10-23
Post by eschwellinger on Automation server - trends stop recording - need to manually reconnect
CODESYS Forge
talk
(Post)
Hi Trent, yes should work without, let me check. Regards Edwin
Last updated: 2024-10-23
Post by thomas-moba on TrueType font problem
CODESYS Forge
talk
(Post)
Thanks for your answers! Close and Open CoDeSys has no effect. I already tried the original Roboto and this is working. But I think our marketing compartment changed it.
Last updated: 2024-10-23
Post by winki on Scan Network on gateway created with Control Sl
CODESYS Forge
talk
(Post)
Thx it is working !
Last updated: 2024-10-23
Login problem with FileTransfer on Raspberry Pi 5
CODESYS Forge
talk
(Thread)
Login problem with FileTransfer on Raspberry Pi 5
Last updated: 2024-10-23
Scan Network on gateway created with Control Sl
CODESYS Forge
talk
(Thread)
Scan Network on gateway created with Control Sl
Last updated: 2024-10-23
TrueType font problem
CODESYS Forge
talk
(Thread)
TrueType font problem
Last updated: 2024-10-23
Post by timvh on Refresh visulization realtime
CODESYS Forge
talk
(Post)
Should work by using the property Dynamic bitmap - Bitmap version. Change the value of the variable you linked to this property after you updated the image. See: https://content.helpme-codesys.com/en/CODESYS%20Visualization/_visu_elem_image.html
Last updated: 2024-10-23
Post by lsislsis on Alarm Table rows font size not change
CODESYS Forge
talk
(Post)
When we try to change the font size of alarm table headers change as excpected but timestamps and messages not change and keep one small size from the begining. Is there any solution for that? Regards
Last updated: 2024-10-23
Post by albertocamina on Login problem with FileTransfer on Raspberry Pi 5
CODESYS Forge
talk
(Post)
Dear eschwellinger, sorry for the late repply. Just saw your answer nor. We are using: -CODESYS V3.5 SP19 Patch 2 -Compiler version - 3.5.19.20 -Visulaization Profile: 4.6.0.0 -CODESYS Control for Raspberry Pi 64 SL 4.12.0.0 All the best!
Last updated: 2024-10-23
Post by koerbejm on Probleme beim aktivieren von Lizenzen
CODESYS Forge
talk
(Post)
Liebe Codesys-Gemeinde, ich habe folgendes Problem und bitte um Hilfe: Um eine auf meinem dem Raspberry Pi laufende Steuerung ohne große Mühe duplizieren zu können, habe ich mir ein Image der SD Karte mit Win32 Diskimager erstellt. Dieses konnte ich bisher ohne weitere Probleme auf eine weitere Micro-SD karte ausrollen. Anschließend habe ich mich via Putty auf den PI geschaltet, die vorherige Lizenz (die ja für den vorheringen PI zulässig war) gelöscht über - sudo su - rm -r /var/opt/codesys/cmact_licenses/ - reboot Um dann via Codesys 3.5 SP16 Patch 4 eine neue Lizenznummer ">>Tools>Lizenzmanager>Lizenz aktivieren" zu aktivieren und das wars. Durch die Umstellung des Lizensierungsverfahrens klappt diese Variante nun nicht mehr. Ich habe mir neue Lizenzen von Codesys gekauf, doch sobald ich diese in die Ticket-ID eintrage und aktivieren möchte bekomme ich folgende Fehlermeldung: ReturnCode: 403046401, An internal error has occured. Please try it again later. (siehe Bild im Anhang "Fehler_Codesys3.5V16.png") Ich habe dann meine Codesys-Version auf Version 3.5 SP20 geupdated und das selbe versucht mit dem Resultat, dass ich nun folgende Fehlermeldung erhalte: "Der ausgewählte Container "...." paßt nicht zu Ihrem Ticket. Bitte wählen Sie einen passenden aus." --> Siehe Bild im Anhang "Fehler_Codesys3.5V120.png" Was genau kann/muss ich tun, damit ich einfach wie bisher meine Steuerungen duplizieren kann? Verwendete Hardware: Raspberry Pi 3 Model B+ Verwendete Lizenz: Codesys Control Basic L Viele Grüße und Danke, Jan
Last updated: 2024-10-23
Probleme beim aktivieren von Lizenzen
CODESYS Forge
talk
(Thread)
Probleme beim aktivieren von Lizenzen
Last updated: 2024-10-23
wiki Discussion
koerbejm
wiki
(Discussion)
Forum for wiki comments
Last updated: 2024-10-23
blog Discussion
koerbejm
blog
(Discussion)
Forum for blog comments
Last updated: 2024-10-23
(no subject)
koerbejm
wiki
(Thread)
Last updated: 2024-10-23
Home
koerbejm
wiki
(WikiPage)
Project Members: koerbejm (admin)
Last updated: 2024-10-23
Post by winki on Modbus TCP & RTU with Control for Linux SL
CODESYS Forge
talk
(Post)
For small project, I would like to use my industrial computer as a PLC + Industrial Computer. Like that I can save the cost of one PLC. That why I am using Codesys on Linux. With the nic it is not working. I already set the IP adress with /etc/network/interfaces. Can it comes from there ? looking to "Control Linux SL" docuemntation it should work with rtu.
Last updated: 2024-10-23
Home (version 1) discussion
koerbejm
wiki
(Thread)
Home (version 1) discussion
Last updated: 2024-10-23