Post by gunstr on CODESYS control on RPi starts, shortly runs, then exits
CODESYS Forge
talk
(Post)
Thank you very much for the quick answer! The RPi hw were delivered last week so it's probably a resent version. I found an old scrapped board (2 years or so) with a broken GPIO that I tested with the same SD card image and with that board Codeys can run for the full 2h demo period without issues. Then I went back the the new board to test the 4.17.0.0 release but the installation fails... [INFORMATION] Standard output: create and install daemon [INFORMATION] Standard output: codesyscontrol started [WARNING] Unable to detect Raspberry Pi Architecture. Setting armv6l as default, you can change this through the settings panel. [INFORMATION] Standard output: codesyscontrol stopped [ERROR] Expected exit value of command failed: expected 0, received 1 [WARNING] Error setting the Raspberry Pi Architecture [ERROR] Error installing codesyscontrol Do you have any idea what could be the reason? I'm using an OS image including Python drivers for LCD and some I/O:s from last year to keep things stable, but also after upgrading with sudo apt update && sudo apt upgrade I still get the same error Reverting back to 4.15.00 works fine: [INFORMATION] Standard output: create and install daemon [INFORMATION] Standard output: codesysedge started [INFORMATION] Successfully installed codesyscontrol [INFORMATION] Successfully started CODESYS Edge Gateway for Linux [INFORMATION] Successfully started CODESYS Control for Raspberry Pi SL but as before the Codesys services stops after 30 seconds. And I noticed that the Codesys control stops and is not reachable also if I have no application loaded.
Last updated: 2025-09-02
wiki Discussion
ilaraujo
wiki
(Discussion)
Forum for wiki comments
Last updated: 2025-09-02
blog Discussion
ilaraujo
blog
(Discussion)
Forum for blog comments
Last updated: 2025-09-02
(no subject)
ilaraujo
wiki
(Thread)
Last updated: 2025-09-02
Home
ilaraujo
wiki
(WikiPage)
Project Members: ilaraujo (admin)
Last updated: 2025-09-02
Home (version 1) discussion
saucedoo
wiki
(Thread)
Home (version 1) discussion
Last updated: 2025-09-03
blog Discussion
dally
blog
(Discussion)
Forum for blog comments
Last updated: 2025-09-03
Post by pernockham on AC Persistence - values are not read from file during start?
CODESYS Forge
talk
(Post)
I swear I tested this like 20 times yesterday without success. Repeated it today and it works. Maybe the system needed a "real" power reboot? To note. To make a manual edit of a variable I tried some different approaches this is what worked for me. "system/online edited" gvl_var.example_variable REAL:F16#2FFB334H-4 767.7 "manually edited" (with runtime stopped followed by a "cold start" to read from file) gvl_var.example_variable REAL:790.1 (the system will use the manual value but will not set an equivalent "hex" value until next online edit/write cycle)
Last updated: 2025-09-03
wiki Discussion
dally
wiki
(Discussion)
Forum for wiki comments
Last updated: 2025-09-03
(no subject)
dally
wiki
(Thread)
Last updated: 2025-09-03
Home
dally
wiki
(WikiPage)
Project Members: dally (admin)
Last updated: 2025-09-03
Post by alexgooi on Codesys virtual control redundancy
CODESYS Forge
talk
(Post)
Dear Forum, I’m currently investigating the possibilities of Codesys virtual control (Linux). The research rig consists of a PC (Debian with real time kernel) with a docker server installed on it. The PC is communicating with a Remote I/O and I have to say the performance is great. The process in the container is running (soft) real time. Currently I’m checking if it is possible to replace physical controllers by remote I/O’s and run the Codesys applications on a docker server. If I’m going into this route the reliability of the server is very important (server down, complete installation down), is it possible to make the server redundant without needing 2 separate containers (including licenses), and maintaining the real time behavior? I’m not only expecting direct answers, if you have any idea or thought they are very welcome. Kind regards Alex
Last updated: 2025-09-03
Post by alexgooi on Execute a .py file with Codesys
CODESYS Forge
talk
(Post)
Hello yann, In the past I have experimented with the execution of Linux commands using Codesys. Maybe this article helps: https://www.linkedin.com/pulse/run-linux-commands-from-codesys-jouke-aalvanger When you are able to execute Linux commands in Codesys, you can run the Python script.
Last updated: 2025-09-03
Execute a .py file with Codesys
CODESYS Forge
talk
(Thread)
Execute a .py file with Codesys
Last updated: 2025-09-03
Post by dkugler on Webvisu Combined Authentication
CODESYS Forge
talk
(Post)
you are able to do this all in one screen. It is possible to set the rights of every element to visible but not editable for the user "none". so everyone is able to see this elements, but can't do any changes. At the login button you set the rights to editable for the user "none" to be able to go to the login. Every element that should be hidden before logging in, set the rights visible and editable only for "higher" users. Hint: to change rights you are able to select more then one element and edit rights for all at the same time. Saves a lot of time! Good luck!
Last updated: 2025-09-03
Post by pernockham on AC Persistence - values are not read from file during start?
CODESYS Forge
talk
(Post)
For the protocol. What also works is to do the process via ssh (using runtime on linux) sudo /etc/init.d/codesyscontrol stop modify the persistence file values sudo /etc/init.d/codesyscontrol start
Last updated: 2025-09-03
AC Persistence - values are not read from file during start?
CODESYS Forge
talk
(Thread)
AC Persistence - values are not read from file during start?
Last updated: 2025-09-03
Webvisu Combined Authentication
CODESYS Forge
talk
(Thread)
Webvisu Combined Authentication
Last updated: 2025-09-03
wiki Discussion
taywinkel
wiki
(Discussion)
Forum for wiki comments
Last updated: 2025-09-03
blog Discussion
taywinkel
blog
(Discussion)
Forum for blog comments
Last updated: 2025-09-03
(no subject)
taywinkel
wiki
(Thread)
Last updated: 2025-09-03
Home
taywinkel
wiki
(WikiPage)
Project Members: taywinkel (admin)
Last updated: 2025-09-03
Post by gunstr on CODESYS control on RPi starts, shortly runs, then exits
CODESYS Forge
talk
(Post)
I now tried to install 4.17.0.0 on a fully clean installations: A brand new RPi 4B Install latest Raspberry Pi OS Lite, Release date 13 May 2025, 64bit run sudo apt update && sudo apt full-upgrade When asked - Select to install the updated version of '/etc/initramfs-tools/initramfs.conf' Install CODESYS Control for Raspberry Pi SL. version 4.17.0.0 Log output: [INFORMATION] Connected successfully! [INFORMATION] Successfully connected to target (192.168.0.197) [WARNING] No supported container engine found on device. You have to install a supported container engine to use Virtual Control. Please contact the Administrator of the device. [WARNING] Error detecting container architecture [INFORMATION] Finished reading device information [ERROR] Error output: /var/lib/dpkg/info/codesyscontrol.postinst: 88: check_legacy_extensionapi_folder: not found [INFORMATION] Standard output: Selecting previously unselected package codesyscontrol. [INFORMATION] Standard output: (Reading database ... 76772 files and directories currently installed.) [INFORMATION] Standard output: Preparing to unpack .../codesyscontrol_raspberry_4.17.0.0_all.deb ... [INFORMATION] Standard output: Unpacking codesyscontrol (4.17.0.0) ... [INFORMATION] Standard output: Setting up codesyscontrol (4.17.0.0) ... [INFORMATION] Standard output: make config rw [INFORMATION] Standard output: set folder permissions [INFORMATION] Standard output: prepare permissions [INFORMATION] Standard output: check legacy extension api folder [INFORMATION] Standard output: create and install daemon [INFORMATION] Standard output: codesyscontrol started [WARNING] Unable to detect Raspberry Pi Architecture. Setting armv6l as default, you can change this through the settings panel. [INFORMATION] Standard output: codesyscontrol stopped [ERROR] Expected exit value of command failed: expected 0, received 1 [WARNING] Error setting the Raspberry Pi Architecture [ERROR] Error installing codesyscontrol If I read the log correctly the control is actually installed but cannot start. I'm running out of ideas how to proceeed now, any suggestions are welcome.
Last updated: 2025-09-03
Virtual Runtime CSV Utility Error
CODESYS Forge
talk
(Thread)
Virtual Runtime CSV Utility Error
Last updated: 2025-09-03
Post by leandroct on Creating Boot Application not working
CODESYS Forge
talk
(Post)
I have a Control Win V3.5 SP20 (64-bit) application, and until now, I open the program (with a password) and download it. However, I need to give the client the option to install the program on the Controller, without them having to open it and access the code. So, I followed these steps: 1 – In the Online => Create Boot Application menu, I saved the generated files in a directory: Application.app Application.crc PlcLogic\visu\ directory with several files 2 – In the SysTray, I ran the PLC, and it created a directory. In the root of this directory (C:\ProgramData\CODESYS\CODESYSControlWinV3x64\E84889DB), I pasted Application.app and Application.crc. Since it created a \visu directory, I pasted the PlcLogic\visu\ files generated in Create Boot Application into it. 3 - In the general Codesys directory (C:\ProgramData\CODESYS\CODESYSControlWinV3x64), I edited CodesysControl.cfg, adding: [CmpLog] Application.1=Application 4 - When running the PLC, nothing happens and the TargetVisu screen does not open. What I'm doing wrong?
Last updated: 2025-09-03