Home
jrisilva
wiki
(WikiPage)
Project Members: jrisilva (admin)
Last updated: 2025-09-08
Post by ranadheer on Codesys Control for PLCnext (PLC - AXL F 2152)
CODESYS Forge
talk
(Post)
Hello Jaco Pretorius, I came across your post regarding CodeSys control for PLCnext. I’m currently working on a similar setup and had a quick question. Here am using the CODESYS V3.5 SP21 PATCH2 ,VERSION 3.5.21.20 , and Downloaded extension package 4.16.0.0 (old versions are not available in the extension CodeSys installer) Devices used here are: BUS COUPLER : 2403869 BK PN TPS Module carrier slot 1 : 1088127 AXL SE DI16/1 Module carrier slot 2 : 1088062 AXL SE AI4 | 4-20 Module carrier slot 3 : 1088129 AXL SE DO16/1 Module carrier slot 4 : 1088123 AXL SE AO4 | 4-20 -->Start a New Project Type: Standard Project Device: CODESYS Control Win V3 x64 Language: Structured Text -->Install GSDML File Navigate to: Tools > Device Repository > Install Select the GSDML file path (downloaded from Phoenix Contact for device coupler Part ID: BK PN TPS 2403869) Click Renew Device Repository Close the dialog -->Add Device to Project -->Right-click on Devices > Add Device Issue: Devices from the repository are not available to select or call into the project! I’d really appreciate any guidance or suggestions you can offer. Best Regards Ranadheer Reddy
Last updated: 2025-09-09
Post by pernockham on Control for linux SL, 4.14.0.0 -> 4.15.0.0 breaks web page access. URL requires authentication
CODESYS Forge
talk
(Post)
Ok, seems user management is enforce from versions later than SP14, is that what I see with 4.14.0.0 -> 4.15.0.0 and later (?)
Last updated: 2025-09-09
Post by ranadheer on Codesys Control for PLCnext (PLC - AXL F 2152)
CODESYS Forge
talk
(Post)
Hello Jaco Pretorius, I came across your post regarding CodeSys control for PLCnext. I’m currently working on a similar setup and had a quick question. Here am using the CODESYS V3.5 SP21 PATCH2 ,VERSION 3.5.21.20 , and Downloaded extension package 4.16.0.0 (old versions are not available in the extension CodeSys installer) Devices used here are: BUS COUPLER : 2403869 BK PN TPS Module carrier slot 1 : 1088127 AXL SE DI16/1 Module carrier slot 2 : 1088062 AXL SE AI4 | 4-20 Module carrier slot 3 : 1088129 AXL SE DO16/1 Module carrier slot 4 : 1088123 AXL SE AO4 | 4-20 -->Start a New Project Type: Standard Project Device: CODESYS Control Win V3 x64 Language: Structured Text -->Install GSDML File Navigate to: Tools > Device Repository > Install Select the GSDML file path (downloaded from Phoenix Contact for device coupler Part ID: BK PN TPS 2403869) Click Renew Device Repository Close the dialog -->Add Device to Project -->Right-click on Devices > Add Device Issue: Devices from the repository are not available to select or call into the project! I’d really appreciate any guidance or suggestions you can offer. Best Regards Ranadheer Reddy
Last updated: 2025-09-09
Post by ranadheer on PHOENIX CONTACT Axioline PLCnext project in CodeSys SodftPLC
CODESYS Forge
talk
(Post)
Hello Everyone, I'm working on a CODESYS Standard Project using CODESYS Control Win V3 x64 with Structured Text. The goal is to integrate a Phoenix Contact device coupler (Part ID: BK PN TPS 2403869) via PROFINET. Here am using the CODESYS V3.5 SP21 PATCH2 ,VERSION 3.5.21.20 , and Downloaded extension package 4.16.0.0 (old versions are not available in the extension CodeSys installer) Devices used here are: BUS COUPLER : 2403869 BK PN TPS Module carrier slot 1 : 1088127 AXL SE DI16/1 Module carrier slot 2 : 1088062 AXL SE AI4 | 4-20 Module carrier slot 3 : 1088129 AXL SE DO16/1 Module carrier slot 4 : 1088123 AXL SE AO4 | 4-20 -->Start a New Project Type: Standard Project Device: CODESYS Control Win V3 x64 Language: Structured Text -->Install GSDML File Navigate to: Tools > Device Repository > Install Select the GSDML file path (downloaded from Phoenix Contact for device coupler Part ID: BK PN TPS 2403869) Click Renew Device Repository Close the dialog -->Add Device to Project -->Right-click on Devices > Add Device Issue: Devices from the repository are not available to select or call into the project! I’d really appreciate any guidance or suggestions you can offer. Best Regards Ranadheer Reddy
Last updated: 2025-09-09
Post by timvh on PHOENIX CONTACT Axioline PLCnext project in CodeSys SodftPLC
CODESYS Forge
talk
(Post)
1) Based on your first screenshot. Do NOT filter on "Phoenix". Then first select the Ethernet adapter (of CODESYS) and add this to your device. 2) Then to this Ethernet adapter add a Profinet Controller of CODESYS. 3) Then to this Profinet Controller, add your Phoenix Profinet coupler/adapter.
Last updated: 2025-09-09
Post by pernockham on Control for linux SL, 4.14.0.0 -> 4.15.0.0 breaks web page access. URL requires authentication
CODESYS Forge
talk
(Post)
After enabling user management, then reverting to "legacy mode" for visu, the web is responding again also for versions later than 4.14.0.0.
Last updated: 2025-09-09
Control for linux SL, 4.14.0.0 -> 4.15.0.0 breaks web page access. URL requires authentication
CODESYS Forge
talk
(Thread)
Control for linux SL, 4.14.0.0 -> 4.15.0.0 breaks web page access. URL requires authentication
Last updated: 2025-09-09
Post by beavel on Opening and saving files with fileOpenSave dialog
CODESYS Forge
talk
(Post)
Tim, you my friend is the best ! Thank you. I wish you a fruitful day.
Last updated: 2025-09-09
Post by pernockham on PHOENIX CONTACT Axioline PLCnext project in CodeSys SodftPLC
CODESYS Forge
talk
(Post)
Pretty much my configuration, see attached.
Last updated: 2025-09-09
Customizing FileOpenSave Dialog and Keypad Integration in Visualization
CODESYS Forge
talk
(Thread)
Customizing FileOpenSave Dialog and Keypad Integration in Visualization
Last updated: 2025-09-09
Post by timvh on Customizing FileOpenSave Dialog and Keypad Integration in Visualization
CODESYS Forge
talk
(Post)
https://content.helpme-codesys.com/en/CODESYS%20Examples/_ex_visu_source_lib_visudialogs.html and https://forge.codesys.com/prj/codesys-example/visudialogs/home/Home/
Last updated: 2025-09-09
Post by ranadheer on PHOENIX CONTACT Axioline PLCnext project in CodeSys SodftPLC
CODESYS Forge
talk
(Post)
Thank you Pernockham, I am using Windows SoftPLC and the device is CODESYS Control Win V3 x64. In the above attached example, the file is Linux-based. This is an external add-on file in the CODESYS installer (CODESYS Control for PLCnext SL). I am trying to implement it without this add-on file.
Last updated: 2025-09-09
Post by ranadheer on PHOENIX CONTACT Axioline PLCnext project in CodeSys SodftPLC
CODESYS Forge
talk
(Post)
Yes I tried with this but it doesn't given any device to add.
Last updated: 2025-09-09
Post by ranadheer on PHOENIX CONTACT Axioline PLCnext project in CodeSys SodftPLC
CODESYS Forge
talk
(Post)
Is my approach to create a project without using PLCnext possible?
Last updated: 2025-09-09
Post by pernockham on PHOENIX CONTACT Axioline PLCnext project in CodeSys SodftPLC
CODESYS Forge
talk
(Post)
The structure should be the same independent of which runtime version. Im using Codesys control for linux SL. Ie, add an ethernet device, then profinet controler then phoenix PN bus coupler.
Last updated: 2025-09-09
Post by ranadheer on PHOENIX CONTACT Axioline PLCnext project in CodeSys SodftPLC
CODESYS Forge
talk
(Post)
Thankyou TimvH ,while searching in every device about the component it is same like above screenshot,and i crosscheck with the device repository but devices are available here.
Last updated: 2025-09-09
Post by pernockham on PHOENIX CONTACT Axioline PLCnext project in CodeSys SodftPLC
CODESYS Forge
talk
(Post)
You should use PLCnext if your device-hw is a PLCnext-un it. As I understand it you are using "CODESYS Control Win V3 x64".
Last updated: 2025-09-09
Post by gseidel on Max lines of code, codesys CNC ?
CODESYS Forge
talk
(Post)
We updated our help on the queue sizes, see this new page for our recommendations: https://content.helpme-codesys.com/en/CODESYS%20SoftMotion/_sm_preprocessing_queuesize.html
Last updated: 2025-09-09
Using an Axis of an Axis Group in Torque Conctrol
CODESYS Forge
talk
(Thread)
Using an Axis of an Axis Group in Torque Conctrol
Last updated: 2025-09-09
Max lines of code, codesys CNC ?
CODESYS Forge
talk
(Thread)
Max lines of code, codesys CNC ?
Last updated: 2025-09-09
Home (version 1) discussion
beavel
wiki
(Thread)
Home (version 1) discussion
Last updated: 2025-09-09
Post by gseidel on Using an Axis of an Axis Group in Torque Conctrol
CODESYS Forge
talk
(Post)
Hi manuknecht, the axis group currently always writes the axis set torque values. If no dynamic model has been configured for the axis group, then the set torques are written to 0. The solution for your use case is to call SMC_GroupUpdate [0] before you call SMC_SetTorque on the axes. This way, the axis group will write 0 to the set torques in the call to SMC_GroupUpdate(), and SMC_SetTorque then will write the desired set torque. Best regards, Georg [0] https://content.helpme-codesys.com/en/libs/SM3_Robotics/Current/SM3_Robotics/POUs/AdministrativeConfiguration/Computation/SMC_GroupUpdate.html
Last updated: 2025-09-09
Post by timvh on PHOENIX CONTACT Axioline PLCnext project in CodeSys SodftPLC
CODESYS Forge
talk
(Post)
In the device selection. Do not filter on Phoenix. Remove this filter and first add an Ethernet Adapter from CODESYS. To this Ethernet adapter add the Profinet Controller. After this you can filter on Phoenix devices in the "add device dialog".
Last updated: 2025-09-09
Post by timvh on Codesys Control for PLCnext (PLC - AXL F 2152)
CODESYS Forge
talk
(Post)
Do not filter on Phoenix devices. First add an Ethernet device (from CODESYS). Then add a Profinet Controller (from CODESYS). Then add your Phoenix devices to this CODESYS Profinet Controller.
Last updated: 2025-09-09