  • Posted a comment on discussion Runtime 🇬🇧 on CODESYS Forge

    ich lese alle 4 Sekunden einen Sensor DS18B20 aus Datei im Verzeichniss /mnt/1wire mit USB-Adapter und owfs [SysFile] IecFilePath.3=/mnt/1wire

  • Posted a comment on discussion Runtime 🇬🇧 on CODESYS Forge

    Hi I made the update from 4.7.0.0 to 4.9.0.0 and have the same problem again. Few weeks ago I tried a other communication way with OWFS. Here I wanted to read the value from file /mnt/1wire/temperatur At least I found the problem that codesys blocks reading from files. I added the two lines in /etc/CODESYSControl.cfg ;raspberry [SysFile] ForceFilePath=0 ForceIecFilePath=0 Now it works again. Regard August