Hi Edwin, could you please post an example.projectarchive and a CODESYSControl.cfg with the location/path to place it? Then we could simply open the archive and compare the CODESYSControl.cfg to our own/replace ours to get this working. In this example project that runs on a Windows machine, could you please have it sending and receiving a CAN message?
I had added my CODESYSControl.cfg. Is it the right file? Correct contents? Do you need a license or something else to make this work?
What other steps are needed? I have now added CmpPCANBasicDrv to C:\ProgramData\CodeSys\CODESYSControlWinV3\F05D572C as well as in the GatewayPLC folder as mentioned above. I also tried uncommenting net 0 in CmpBlkDrvCanServer.
Hello, I have "No CAN driver found! (error code: 16#27E2)" I have added " [ComponentManager] Component.1=CmpPCANBasicDrv " to my CODESYSControl.cfg in GatewayPLC folder. I have Control Win V3 Version 3.5.17.0 running and when I scan, I find my local PC and am able to login and download. I have PCAN-View running, I've tried without it running as well. I also contacted Peak and they mentioned drivers, I have them installed, I use PCAN-View and PCANApi almost every single day. What else could I be missing?...
Hello, I have "No CAN driver found! (error code: 16#27E2)" I have added " [ComponentManager] Component.1=CmpPCANBasicDRV " to my CODESYSControl.cfg I have Control Win V3 Version 3.5.17.0 running and when I scan I find my local PC and am able to login and download. I have PCAN-View running, I've tried without it running as well. I also contacted Peak and they mentioned drivers, I have them installed, I use PCAN-View and PCANApi almost every single day. What else could I be missing? I have also attached...
Hello, I have "No CAN driver found! (error code: 16#27E2)" I have added "[ComponentManager] Component.1=CmpPCANBasicDRV" to my CODESYSControl.cfg I have Control Win V3 Version 3.5.17.0 running and when I scan I find my local PC and am able to login and download. I have PCAN-View running, I've tried without it running as well. I also contacted Peak and they mentioned drivers, I have them installed, I use PCAN-View and PCANApi almost every single day. What else could I be missing? I have also attached...
Can someone please help me find this setting?
I am using CAN API and trying to use a true listen only mode, where the CODESYS device doesn't even send acknowledge to received messages. CAN sniffers like PeakCAN have this mode. I have tried using only the CAN.CANBus_29bit function block, I have also tried only using the CL2.DriverOpenH function, without any transmit or receive function blocks at all. If I use an incorrect baud rate the CODESYS device will cause error frames (seen by Kvaser CANKing or PeakCAN). I need to have complete listen only...