gatto, That works. Thanks. Typically I use my mouse more than my keyboard. That's why I was looking for a delete option from the right-click context menu or a delete button on a toolbar at the top. It never occured to me to use the keyboard. It might be a little more user friendly if they allowed a mouse wise ability to remove a line from the grid as well as the DEL key. Just a suggestion. Thanks for your help.
here is a screenshot. I dragged Device.Application > GVL_Sched > Requests to the grid on the right, but I cannot remove it from the grid.
Right now when I make a change to one of the tags in my code, I have to completely remove the IEC Symbol Publishing object from the tree view and re-add it. Then I have to completely re-add every symbol to the grid view by dragging them over. This can be a lot. Surely, this is not the intended behavior. Can anyone tell me how this is supposed to work?
In the CODESYS IDE I have several symbols defined and I have IEC Symbol Publishing installed. On the IEC Symbol Publishing window and under the IEC Symbols Editor tab, I have dragged symbols from the tree on the left to the grid on the right. All this works fine. Now I want to remove one of the symbols from the grid on the right and I cannot see any way to do this. How can I remove a symbol from the grid on the right once I've added it?
Ok, for the sake of completeness in case anyone else has this problem. I can tell you that what finally worked for me was to change the line: // create an ExtensionObject to wrap the value to be written ExtensionObject extensionObject = new ExtensionObject( new ExpandedNodeId("GVL_StructA", 5), structAData ); to: // create an ExtensionObject to wrap the value to be written ExtensionObject extensionObject = new ExtensionObject( new ExpandedNodeId("GVL_StructA|defaultbinary", 5), structAData ); I'm...
Ok, I have a simple test environment. From C#, using OPC UA, I can read DINTs, write DINTs, read Structs, but when I try to write a struct I get BadNotWritable. I am using Communication Manager, OPC UA Server, and IEC Symbol Publishing. I have a struct defined with one single DINT in it. The instance of the struct is in GVL. The struct is marked read/write in IEC Symbol Publishing. Any ideas? Pointers are welcome. public static async Task WriteStructA(byte[] structAData) { if (_session == null) throw...
mainak, sorry, just saw your post. I have done that and I still get the same exception. the innerResult says "BadSecureChannelClosed 'Remote side closed connection'". Any other tips? Pointers are welcome.
sadly, no