  • Modified a comment on discussion Runtime 🇬🇧 on CODESYS Forge

    Since version 19 they changed how file access is handle. There are two solutions: 1. You change where the file is stored (need to go to: /PlcLogic/) 2. You can, if you don´t want to store at PlcLogic, add the following line in the CODESYSControl.cfg under [SysFile]: ForceIecFilePath=0 The CodesysControl.cfg is at C:\ProgramData\CODESYS\CODESYSControlWinV3x64\xxPROJECT_NUMBERxx\ Here the email they sent me: "with the 3.5.19 Version we changed how files are handled. See following issue: CDS-81506 -...

  • Posted a comment on discussion Runtime 🇬🇧 on CODESYS Forge

    Since version 19 they changed how file access is handle. There are two solutions: 1. You change where the file is stored (need to go to: /PlcLogic/) 2. You can, if you don´t want to store at PlcLogic, add the following line in the CODESYSControl.cfg under [SysFile]: ForceIecFilePath=0 The CodesysControl.cfg is at C:\ProgramData\CODESYS\CODESYSControlWinV3x64\xxPROJECT_NUMBERxx\ Here the email they sent: "with the 3.5.19 Version we changed how files are handled. See following issue: CDS-81506 - CODESYS...

  • Posted a comment on discussion Engineering 🇬🇧 on CODESYS Forge

    Codesys changed the license system (https://store.codesys.com/en/howto_applicationbasedlicenses). How do I know which license package my project will fit into? - I understood that one of the determinants of the package is the size of the application, but where can I see this size? (I put attached a picture with some size information I see). - My application uses 8 cores. I saw a package that says up to 4 cores. How to use 8 cores? - My application has no I/O. It only reads TCP/IP packets from 3 sensors...

  • Modified a comment on discussion Engineering 🇬🇧 on CODESYS Forge

    Yes. I configured this Access Control for each POU, but this is only valid for Online. In offline, the user can view and change all the program. For now, I'm putting a password to open the entire program, but I would like that users could view/ change parts of the program.

  • Posted a comment on discussion Engineering 🇬🇧 on CODESYS Forge

    Yes. I configured this Access Control for each POU, but this is only valid for Online. In offline, the user can view and change all the program.

  • Posted a comment on discussion Engineering 🇬🇧 on CODESYS Forge

    I made an application in Control Win 3.5.SP16. I created users and groups and defined to each POU the permissions (View/ Modify/ Remove) for each group. However, these settings are only valid for the online program. If someone opens my application, they see the entire program. I would like that the offline program also require a user login so that only the permited part of the program appears to the user according to the permissions defined for the user's group. Is this possible?

  • Posted a comment on ticket #173 on CODESYS Forge

    Yes. For some reason it lost CodesysControl.cfg I'm doing a backup of it now to be able to restore, but this shouldn´t happen.

  • Created ticket #173 on CODESYS Forge

    Unresolved references only in a specific machine with "Control Win"