Personal Data

Username:
lingvo
Joined:
2020-09-28 09:20:22

Projects

  • No projects to display.

User Activity

  • Posted a comment on discussion Visualization πŸ‡¬πŸ‡§ on CODESYS Forge

    I had the same question and Multitouch option solved the problem of emulating long press, but Chromium still opens pup-up menu on long touch. I tried --kiosk option, and this works, but then one can't exit the browser anymore. Any other ideas?

  • Posted a comment on discussion Runtime πŸ‡¬πŸ‡§ on CODESYS Forge

    Any suggestions anyone? I had to remove ac_datalog from the project as at this stage it is unsuitable for prolonged use and crashes the system after few tens of hours.

  • Posted a comment on discussion Runtime πŸ‡¬πŸ‡§ on CODESYS Forge

    Sometimes Internet is not available and even WLAN too. So BT would be a good solution.

  • Posted a comment on discussion Runtime πŸ‡¬πŸ‡§ on CODESYS Forge

    Yeah, would be interested on how to add Bluetooth connectivity to Codesys Runtime too. In my case it is a kind of communication with smartphone (a kind of simple HMI) via Bluetooth as WiFi would not be acceptable.

  • Modified a comment on discussion Runtime πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi there. I'm using RPi 3 in my lab with Codesys licence (3.5.SP15) as a controller for a test stand. Sometimes this equipment runs 24/7 and it did it without any issues so far. Very good stability. But recently I wanted to add data logging capability to my system, so I have installed ac_datalog module through composer. I've created one datalog channel and added there my boolean variables (about 50 variables). My runtime runs at 2ms, but for datalogger high task I runs at 5ms. When I tried it first...

  • Modified a comment on discussion Runtime πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi there. I'm using RPi 3 in my lab with Codesys licence (3.5.SP15) as a controller for a test stand. Sometimes this equipment runs 24/7 and it did it without any issues so far. Very good stability. But recently I wanted to add data logging capability to my system, so I have installed ac_datalog module through composer. I've created one datalog channel and added there my boolean variables (about 50 variables). My runtime runs at 2ms, but for datalogger I used 5ms. From the beginning it worked nice...

  • Posted a comment on discussion Runtime πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi there. I'm using RPi 3 in my lab with Codesys licence (3.5.SP15) as a controller for a test stand. Sometimes this equipment runs 24/7 and it did it without any issues so far. Very good stability. But recently I wanted to add data logging capability to my system, so I have installed ac_datalog module through composer. I've created one datalog channel and added there my boolean variables (about 50 variables). My runtime runs at 2ms, but for datalogger I used 5ms. From the beginning it worked nice...

  • Posted a comment on discussion Runtime on CODESYS Forge

    But actually if CODESYS Automation Server is going to stay free - I will try it. Do I just need Internet connection on my Codesys RPi?

View All