Activity for lota

  • lota lota posted a comment on discussion Visualization ๐Ÿ‡ฌ๐Ÿ‡ง

    ืŸืŸื7 On Fri, Jun 23, 2023, 17:20 TimvH no-reply@codesys.com wrote: Maybe this helps: https://forge.codesys.com/prj/codesys-example/visudialogs/home/Home/ ? How to change keyboard layout on the virtual keyboard? https://forge.codesys.com/forge/talk/Visualization/thread/d17645d99f/?limit=25#b36f Sent from forge.codesys.com because you indicated interest in https://forge.codesys.com/forge/talk/Visualization/ To unsubscribe from further messages, please visit https://forge.codesys.com/auth/subscript...

  • lota lota posted a comment on discussion Visualization ๐Ÿ‡ฌ๐Ÿ‡ง

    Hi all Our system generates a log file with several levels. We need to display this log on the visu. Each level should have its own color and there should be a filter to show only necessary levels (for example, DEBUG level should not be shown, only on demand). Another nice to have option will be automatic refresh of the log. This is a necessary option to understand cause of errors. I couldn't find any built-in element which will give me an option of having colored text. Only option that I could come...

  • lota lota posted a comment on discussion Visualization

    I really hope 3S will take care of this issue, as it seems to be a drawback for many users. Meanwhile, my solution is a bit complicated but its the only one I could come up with: I'm building an Android app with a webpage inside that runs the webvisu, and has a modbus server running, that keeps updating the PLC when the activity is in focus. Once the activity loses focus, the modbus stops shooting, and release every tap button that was pressed. It is still in development, so I can't share it, but...

  • lota lota posted a comment on discussion Visualization

    For those who suggest using hardwired buttons, it is not possible in my application. There are many "manual" buttons and our HMI should be mobile. You have to Walk around the site in order to operate different sections. It is not possible to put multiple panels around, because then we will need tens of them... One of the reasons we have chosen Codesys for our application is the versatility and high end technology it introduce. I think that asking a button to stop operating in case of connection loss...

  • lota lota posted a comment on discussion Visualization

    OK. I Managed to use this code and it partly works. but I still have a problem: Assuming operators devices loses the browser focus for some reason, the button stays pressed! this is very dangerous. previous solution still recognize the client, but button will not stop the tap... any ideas?

  • lota lota posted a comment on discussion Engineering

    Hi All I have about 12 instances of a FB, all can trigger the same alarms in the alarm manager. I'm trying to find a way to let the user know which of the instances has trigger the alarm. any ideas?

  • lota lota posted a comment on discussion Visualization

    Hi We are using Codesys for heavy industrial machinery. One thing our technicians have to do is to manually operate the system. For that, we have a Webvisu running on a panel pc, with several Tap buttons. They hold the button to operate an hydraulic piston for example. In my tests I noticed that if, for some reason, the connection is lost while a button is pressed, it will stay pressed. This is very dangerous and can end up in heavy damage. I'm looking for a way to avoid that. Tried to look at visustructclientdata....

1