Post by budd7566 on Text size suddenly changed
CODESYS Forge
talk
(Post)
Iv been working with a Deep Sea Electronics DSE840 for about 6 months. I have a development version of my program working with a state machine and a basic gui interface. I went to implement CAN and suddenly the text on the gui on the controller is much larger than before. I could flash old versions of my project and the text was the correct size, but if i renamed the project file, the text displayed would be large. The visualization in CODESYS always shows the expected size, but not the controller. I did a fresh install of CODESYS and even a new project with only one text box, I cant get the text size on the controller to match what is displayed in codesys to match. Any advice?
Last updated: 2023-12-09
Post by kevinl on RevPi Connect RS485
CODESYS Forge
talk
(Post)
I figured this out on my own with this logic: usually the Serial port on a Raspberry pi is on /dev/ttyUSB0 then you need to set linux.DeviceFile=/dev/ttyUSB in codesys you then must set com port to 1 so i assumed codesys subtracts 1 from the number and adds this to the filename... (in code it would look like this: var comPort : byte := '1'; linuxDevice : string := '/dev/ttyUSB'; filename : string; end_var filename := concat(linuxDevice, (to_string(comPort-1)); filaname then is /dev/ttyUSB0 RevPi uses ttyRS485 as Serial port so you must remove the last number from the name and set the com port to this number +1 i hope this is understandable ;-)
Last updated: 2023-12-11
Post by eschwellinger on Profibus Master using Softing ProfiUSBpro
CODESYS Forge
talk
(Post)
this is not possible. Only for Control Win plc this driver will work.
Last updated: 2023-12-11
Post by snhatton on OpC UA server on Raspberry Pi 64 SL runtime
CODESYS Forge
talk
(Post)
Good afternoon, After changing the security settings to: CommunicationPolicy: POLICY_BASICSHA256SHA256 CommunicationMode: ALL Activation: Activated UserAuthentication: ENABLED Then generate a new certificate on the device for the OPC-UA server from Security Agent->Device->OPC UA Server. Restart the runtime using tools->Update Raspberry Pi->Stop->Start for the changes to take effect. It may take a minute for the runtime to start. Initiate the connection from the UA server side. You should see a pop-up asking you to trust the certificate. Click on the button 'Trust Server Certificate'. Next, you should see a certificate in the quarantined folder of the security agent in CODESYS. Click and drag this from quarantined to trusted and then try connecting from UA expert to the device. These steps worked for me and my setup and I hope they can help you!
Last updated: 2023-12-11
Post by arwie on Possibility to deactivate CmpBlkDrvUdp
CODESYS Forge
talk
(Post)
It works! MaxInterfaces=0 deactivates the UDP backend [CmpBlkDrvUdp] MaxInterfaces=0 Thank you!
Last updated: 2023-12-13
Post by trycyclepower on How to transfer data from DINT to Union(16 Bools) which I need to use in Few FBs
CODESYS Forge
talk
(Post)
Thanks a lot, it worked.
Last updated: 2023-12-14
Post by ph0010421 on How to transfer data from DINT to Union(16 Bools) which I need to use in Few FBs
CODESYS Forge
talk
(Post)
In the Struct, change the 'BOOL' to 'BIT'
Last updated: 2023-12-14
Post by simotion on Property
CODESYS Forge
talk
(Post)
Why can't a property be of type REFERENCE TO? Plc goes to stop if I try that.
Last updated: 2023-12-14
Post by snhatton on Some visualization objects disappear when user is logged in?
CODESYS Forge
talk
(Post)
Did you check the access rights of the visualization elements in question?
Last updated: 2023-12-18
Post by user0815 on Web Socket Client SL -Bibliothek Fehler
CODESYS Forge
talk
(Post)
Sobald ich probiere eine Nachricht von Node-RED an Codesys zusenden.
Last updated: 2023-12-18
Post by eschwellinger on Web Socket Client SL -Bibliothek Fehler
CODESYS Forge
talk
(Post)
bei welcher Aktion kommt dieses Fenster mit dem Source Code?
Last updated: 2023-12-18
Post by eschwellinger on Application based license problem - Modbus TCP
CODESYS Forge
talk
(Post)
you could sent the projectarchive to 'my question' in the CODESYS store
Last updated: 2023-12-18
Post by eschwellinger on Web Socket Client SL -Bibliothek Fehler
CODESYS Forge
talk
(Post)
aber sind dann nicht auch exceptions im Log zu sehen?
Last updated: 2023-12-18
Post by giglecald on Visualisations in Frames
CODESYS Forge
talk
(Post)
Almost 2024 and I'm looking for this too XD Can't seem to find a way to get the current visualization inside a frame
Last updated: 2023-12-19
Post by simover on TCP/IP client
CODESYS Forge
talk
(Post)
HELLO thank for you answer!! I'm a beginner can you give me an example?
Last updated: 2023-12-19
Post by eschwellinger on Raspberry Pi 4 with Legacy Drivers and Codesys 3.5.19 Patch 4
CODESYS Forge
talk
(Post)
what if you use all packages in latest version? pi Runtime 4.10.0.0 ?
Last updated: 2023-12-19
Post by eschwellinger on Eoe issues with Windows and Linux
CODESYS Forge
talk
(Post)
I think it must be tap0 for EOE https://faq.codesys.com/pages/viewpage.action?pageId=146178174 otherwise it will not work
Last updated: 2023-12-20
Post by fhrask on CoDeSyS OPC DA stops working
CODESYS Forge
talk
(Post)
Did you find the solution for this issue? i'm having the exact same issue with a new machine at the moment....
Last updated: 2023-12-21
Post by user3000 on Can't find an Extended Pulse Timer (TP and LTP)
CODESYS Forge
talk
(Post)
Here is my work-around FBD.
Last updated: 2023-12-21
Post by macman on CoDeSyS OPC DA stops working
CODESYS Forge
talk
(Post)
Yes. I bought license and installed latest CoDeSys OPC DA version.
Last updated: 2023-12-21
Post by sawicpx on CANbus Remapping PDOs During Runtime
CODESYS Forge
talk
(Post)
Hello, I am working on an application where I need to remap PDOs to a different CANopen object during runtime depending on what value is at a specific register. I have gotten to the point where I put the device into Preoperational State using the CIA405.NMT function. I then reconfigure the PDO 180x and 1a0x obejcts usings SDOs to point to a new canopen object on the device however when I go to restart the Device from PREOP to OP using the CIA405.NMT function the device is reset back to the original configuration as per the initial setup. I am wondering is there any way to change the PDOs at runtime is there some more functionaility I can access to do this. Any direction is appreciated!
Last updated: 2023-12-22
Post by kumareasu on Control Runtime Toolkit
CODESYS Forge
talk
(Post)
I too have same requirement. Could anyone can share the hardware proven withCoDeSys ?
Last updated: 2023-12-26
Post by dhumphries on Codesys device configuration
CODESYS Forge
talk
(Post)
First make sure the programming laptop and HMI are both on the same subnet. For example if the IP address of the HMI is 192.168.1.125 with a subnet mask 255.255.255.0 set your laptop IP to 192.168.1.120 with a subnet mask of 255.255.255.0. Make sure the cables are fully connected (the ethernet port on my programming laptop will click once but the cable is not fully seated.) Make sure the HMI is powered on, try pinging the device from a command prompt, if you can't ping the HMI there is a network issue that has to be resolved first.
Last updated: 2023-12-30
Post by andrax on Raspberry Pi: List of available drivers / libraries
CODESYS Forge
talk
(Post)
Take a look at my collection, which I uploaded a few days ago
Last updated: 2023-12-31
Post by user0815 on Web Socket Client SL -Bibliothek Fehler
CODESYS Forge
talk
(Post)
So ich habe das Problem gelΓΆst. Ich habe pData nicht mit einer Variabele vom Typ XWORD verbunden. Jetzt funktioniert die Kommunikation
Last updated: 2024-01-03
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.