Post by dom4u on Using PEAK CAN PCIe card (IPEH-004040) with Codesys Control RTE V3 CODESYS Forge talk (Post)
The problem is that newer PeakCAN cards are with CAN FD support and SJA1000 compatibility isnt mentioned anymore on website. anyway, is it possibile to add a seperate entry for it in: [CmpSJACanDrv] ? Edwin, can you give us a hint how to format it?
Last updated: 2024-12-16

Post by mtnkyr on Runtime Problem connecting to Keyence IV-500MA Camera CODESYS Forge talk (Post)
I have to use Keyence IV-500MA Camera for a project. Actually I can use physical connection but I tried to connect using Ethernet protocol so I added its EDS file but I took a lot of errors. Could you help me to solve this problem?
Last updated: 2024-12-26

Post by mtnkyr on Runtime Problem connecting to Keyence IV-500MA Camera CODESYS Forge talk (Post)
I have to use Keyence IV-500MA Camera for a project. Actually I can use physical connection but I tried to connect using Ethernet protocol so I added its EDS file but I took a lot of errors. Could you help me to solve this problem?
Last updated: 2024-12-26

Post by winki on Warning attribut no_assign CODESYS Forge talk (Post)
Hello, I have two warning on my code, and I would like to understand why. C0540: Attribut 'no_assign' missing for the 'FB_MOdbusReadHolding'. The type of the variable clientTcp is set to 'no_assign'. In this FB, I have done: clientTcp : ModbusFB.ClientTCP; clientRequest : ModbusFB.ClientRequestReadHoldingRegisters; The error comes from clientTcp : ModbusFB.ClientTCP; I am using ModbusFB 4.4.0.0. Thx a lot
Last updated: 2025-01-10

Post by winki on Warning attribut no_assign CODESYS Forge talk (Post)
Hello, I have two warning on my code, and I would like to understand why. C0540: Attribut 'no_assign' missing for the 'FB_MOdbusReadHolding'. The type of the variable clientTcp is set to 'no_assign'. In this FB, I have done: clientTcp : ModbusFB.ClientTCP; clientRequest : ModbusFB.ClientRequestReadHoldingRegisters; The error comes from clientTcp : ModbusFB.ClientTCP; I am using ModbusFB 4.4.0.0. Thx a lot
Last updated: 2025-01-10

Post by teichhei on The selected container ... does not fit your ticket CODESYS Forge talk (Post)
After correspondence with Mr Schwellinger from Codesys the resolution for this was to uninstall the SL 4.14 and install SL 4.13 on the device. Once this was done the licensing worked as expected. I noted that the container then showed a Version 3.00 and not 0.00.
Last updated: 2025-01-11

Post by ekristoffe on Modbus UDP CODESYS Forge talk (Post)
UDP has no packet ordering mechanism, and Modbus protocol has no order checking mechanism nor session establishment. I'm sorry but this is false, Modbus IP based have the Transaction Identifier. Transaction Identifier - It is used for transaction pairing, the MODBUS server copies in the response the transaction identifier of the request. Modbus UDP make more sense than Modbus TCP in a local environment.
Last updated: 2025-01-14

Post by pernockham on Preferred way of managing Ip-adress/es for linux (debian) host? CODESYS Forge talk (Post)
I have a debian linux host running Control SL. I tried to manage IP-addresses through codesys/Control SL but that was not successful. What works though is manually editing the network-interfaces config file. /etc/network/interfaces. Is there a way to set this up so that IP-addresses can be managed from within codesys instead? Thanks! / Per
Last updated: 2025-01-22

Post by imdatatas on Problem with edge gateway config mode CODESYS Forge talk (Post)
I encountered the same problem. (Windows10 x64 single language OS). As @eschwellinger mentioned, I uninstalled the latest EdgeGateway version and installed version 3.5.20.0. Now, when I right-click and select "Allow Edge Gateway...", Config mode is activated without any error or warning window and I do not need to manually type [CmpEdgeGateway] for EdgeGateway version 3.5.20.0.
Last updated: 2025-02-04

Post by mubeta on UNION statement is not supported in the ethercat data exchange CODESYS Forge talk (Post)
Hi all, I am using a unionn statement for merge in integer data type some values that are received in byte from the i/o cards, but, using this simple and light technique, is not recognized by the ethercat data exchange and in fact the tags are not updated. In my opinion it's a very big bug.
Last updated: 2025-02-05

Post by spiritcore on Server not adding PLC CODESYS Forge talk (Post)
I added new Gateway and I can see it connected. When I scan the server for PLC, it finds the PLC but when I click the Add To Server button, it shows "PLC was added." in the status. But I can't find the PLC in the list. I tried removing the gateway and re-configure everything again but it didn't solve. Any ideas?
Last updated: 2025-02-17

Post by jeffersonhui on SP20 Visualization Element Dynamic Colors CODESYS Forge talk (Post)
I am using Codesys SP20 patch 5 and in a visualization element, the "Color variables" section does not have a section to set up dynamic color values linked to variables. In a previous version (SP18), I get the option to add variables for Normal & Alarm state colors. Does anyone know how to get the dynamic color variables to work?
Last updated: 2025-02-19

Post by clarenced on Multiple applications on one device sharing variables. CODESYS Forge talk (Post)
Sounds feasible, but how would I create this object so that both applications would use the same instance of it. If this did work, it's still not really the solution I am looking for as it would mean mapping every variable I want to use on the hmi through this object vs I was hopping all the GVL variables would be available.
Last updated: 2025-02-20

Post by smic on Virtual Control SL Profinet connection CODESYS Forge talk (Post)
Hi. I'm trying to connect Profinet device with Virtual Control for Linux SL. After adding devices, I couldn't find actual device by Scan Device? Do I missed something? VPLC container on Docker IP: 172.17.0.4 Subnet: 255.255.0.0 Gateway: 172.17.0.1 Profinet device: AL1100 io-link master (default setting) IP: 0.0.0.0 Subnet:0.0.0.0 Gateway:0.0.0.0
Last updated: 2025-02-28

Post by helcioburd on How long can a WSTRING be in CodeSys V3? CODESYS Forge talk (Post)
Thank you, very useful information. I did a library for serial communication and could not understand the reason only 256 chars could be read (after sending more than 256). Following your suggestion, I can now send any number of chars and everything will be received.
Last updated: 2025-03-02

Post by hassaank on CODESYS V3+ WAGO PFC200+ MODBUS RTU CODESYS Forge talk (Post)
Hi everyone, I’m new to CODESYS and Wago devices, and I’m trying to set up Modbus RTU communication. I have a Wago PFC200 (8110) and a 750-653 RS485 module, and I want to read data from an energy meter using Modbus RTU. Thanks in advance for your help!
Last updated: 2025-03-17

Post by yannickasselin on Engineering IDE from linux? CODESYS Forge talk (Post)
I have been running Codesys IDE in VirtualBox on a Linux Mint host for many many years without issues. I use it every day and it works great. I wouldn't mess around with wine. Would probably just be a waste of time. Codesys Go might be the future of PLC programming on Linux! Can't wait to test it.
Last updated: 2025-03-17

Post by peterkcontrols on Codesys Network driver install for Codesys Control RTE x64 CODESYS Forge talk (Post)
I am using Codesys Control RTE V3 Version 3.5.21.0 I am not sure what you are asking. Which hardware ID has the network interface card? I have ran ipconfig /all and attached an image. Let me know what other information I can provide to you to help troubleshoot this problem. Thank
Last updated: 2025-03-18

Post by lacypaige on Engineering Dissertation Help & Assignment Assistance. CODESYS Forge talk (Post)
This thread is for discussing engineering dissertation help, including research methods, choosing a topic, writing, and data analysis. Whether you need advice on structuring your dissertation, understanding industry trends, or solving research challenges, this is the place to ask questions and share ideas. Feel free to exchange tips, discuss best practices, and get support with engineering assignments and dissertations.
Last updated: 2025-03-19

Post by eschwellinger on Codesys Network driver install for Codesys Control RTE x64 CODESYS Forge talk (Post)
Yes, either adding in the CODESYSContro_User.cfg because the driver will no longer appear in the list or type the name from the documentation in the configuration and when the gray check mark appears, the driver is also installed. It is just not selectable anymore.
Last updated: 2025-03-21

Post by madskaizer on Exception when OPCUA datasource disconnects from Server CODESYS Forge talk (Post)
We have similar issues, with crashing PLCs, but this ranges from 3.5.16.40 to 3.5.19.70. Which log made you confirm the exception crash? I am currently looking for evidence of what causes our PLCs to crash. Network stability could be an issue with latest security roll-outs like 802.1X and segregation.
Last updated: 2025-03-31

Post by kevinm on Programmatically change Tappet on a cam CODESYS Forge talk (Post)
I am considering using a SoftMotion cam and tappets to activate functions on a machine - for example, triggering a pneumatic valve. I need the ability to change the actuation point (tappet "X" location) from the HMI during machine commissioning. Is there a way to change the "X" value of a tappet programmatically?
Last updated: 2025-04-01

Post by eaglealex on Length of string and Array of bytes CODESYS Forge talk (Post)
Thank you for your answer! I know that 0 will be the end of the string. I checked it. There is no 0 in array of bytes. I made screenshots. There is array of bytes, aborted string and the result of my test via online converter.
Last updated: 2025-04-02

Post by kevinm on Attaching Trace variable to Frame Configuration Variable CODESYS Forge talk (Post)
Is it possible to show a variable from a Frame Configuration in a Trace on that Visualization? I want to pass the FB for an AXIS_REF_ETC_SoE_Standard to the visualization and display live axis data in the visualization. However, I cannot find a way to use a Frame Configuration variable in the Trace Configuration dialog.
Last updated: 2025-04-04

Post by mucleus on How do I fix ";Internal Error (x86-64): Invalid type size" error? CODESYS Forge talk (Post)
I opened the project file of version 3.5.19.7 in 3.5.21.0. I updated all the environment of the project to the latest and compiled it. When I compile it, I get an error ";Internal Error (x86-64): Invalid type size". How can I fix this error? I will wait for your help.
Last updated: 2025-04-15