Post by mejak on Raspberry Pi USB HID RFID Reader - read ID in plc program
CODESYS Forge
talk
(Post)
Hello, I have an RFID reader that is detected as a keyboard. While looking for information, I came across examples using visualization. I would like to read the ID without visualization or external code in python, only in PLC. I found on the forum that you can try reading directly from potru /dev/... https://forge.codesys.com/forge/talk/Runtime/thread/24b3527036/ How to read values directly in codesys? Or maybe there is another solution? Best Regards
Last updated: 2024-01-25
Post by martinlithlith on Raspberry Pi: List of available drivers / libraries
CODESYS Forge
talk
(Post)
As most of the posts are moved here around 2015, what would be the right version of codesys to run? Would it be better to install a older version of codesys or should i keep on downgrading libraries? Is there any work done to update theses libraries? It´s been a few years since the last update in this post, are there new libraries/devices for raspberry being added/posted somewhere else? Thanks, Martin
Last updated: 2023-10-17
Post by eschwellinger on CODESYS Control for Linux ARM SL (32 bit) on Moxa UC-3100 IPC
CODESYS Forge
talk
(Post)
I would recommend to ask Moxa for a newer version of Debian. Debian 9 ("Stretch") has reached its end of life and is no longer receiving security updates from the official Debian Security Team as of June 30, 2022. This means any systems still running Debian 9 are vulnerable to security risks and should be upgraded to a newer, supported version of Debian like Debian 10 ("Buster") or Debian 11 ("Bullseye").
Last updated: 2025-07-14
Post by bmatlove on AXIS_REF_SM3 Error Codes?
CODESYS Forge
talk
(Post)
I'm trying to firm up alarming of axis faults. Declutter the code and figure out what's what. Diving into it, I see the AXIS_REF_SM3 function block provides uiDriveInterfaceError and dwErrorId, but I can't find any significance of these further than Drive interface error number Parameter number: 1014 and Drive specific error identifier, parameter number: 1031, respectively. Is there some corresponding appendix I could use to decode these? Also, is there any relation to the Error ID (of type SMC_Error) of the MC POUs? MC_Jog, MC_Reset, MC_MoveRelative, etc? If so, are the above errors redundant? Thanks in advance.
Last updated: 2025-09-22
Post by tib0r on c2iec - translating C to ST
CODESYS Forge
talk
(Post)
I was looking for a transpiler from some more widely used general programming language into ST. It was not easy but I found this :) https://forge.codesys.com/tol/c2iec/home/Home/ Does anybody use it for a programm/library of a couple of hundred lines or more? How does one go about using the output? Is there a “converter” into the Codesys IDE? PLCOpenXML? Would there be interest in this? tib0r
Last updated: 2024-04-20
Post by mmoncada on Dinamically loading recipes
CODESYS Forge
talk
(Post)
I'm having trouble with the initial loading of recipes. I can create them and load one or the other, but when the program restarts the recipes are not listed. I'm calling: RecipeManCommands.ReloadRecipes and then RecipeManCommands.GetRecipeCount which returns 0 recipes. None of the methods returns error and if i call them again after RecipeManCommands.CreateRecipe RecipeManCommands.ReadAndSaveRecipe getRecipeCount returns the number of recipes created. When i restart the system, once again they are not listed even though the recipe files are there. Any ideas? Martin Btw, Codesys 3.5 SP 16 Path 9
Last updated: 2023-12-06
Post by wehling-h on PI Input value
CODESYS Forge
talk
(Post)
Hi geoweil, have you tried to save changed values to remanent area or using a VAR RETAIN? After restart you have to initialize Counter with last remanent value. Depending on changes per cycle and the possibilitiy of your control unit to write remanent storage. Otherwise you need a buffering system to ensure save backup of last PI_Counter value. May you could read this Thread to get further help: https://forge.codesys.com/forge/talk/Engineering/thread/31e1c8349e/#bf48
Last updated: 2024-01-12
Post by dhumphries on Control for Linux SL on Ubuntu Core
CODESYS Forge
talk
(Post)
Try using a password instead of a public key to log into the controller. I have a video showing how to do this on a default installation of Ubuntu server, it should work the same for Ubuntu Core. https://youtu.be/rj0dOhgnGjs?si=352PmveEP7JXZnO- I sign in to the controller at about 6:40 in the video. I have never tried to remove the public key and revert to signing in using a password, but it looks pretty straightforward https://askubuntu.com/questions/745423/how-to-turn-off-password-less-login-for-ssh
Last updated: 2024-02-28
Hi, I try to send and receive data using a UDP connection via SysSocket 3.5.17.0. While sending data works fine, I have problems with the receiving part. I am able to capture the received data of client side in wireshark But unable to capture it on the codesys
CODESYS Forge
talk
(Thread)
Hi, I try to send and receive data using a UDP connection via SysSocket 3.5.17.0. While sending data works fine, I have problems with the receiving part. I am able to capture the received data of client side in wireshark But unable to capture it on the codesys
Last updated: 2024-06-03
Post by fugtwad on Automation Builder V2.5 EtherCAT CM579 Master Scan for devices - >No gateway selected
CODESYS Forge
talk
(Post)
ABB Automation Builder v2.5.0.22 Premium CodeSys 2.3.9.62 Running on Win 10 VM x64 Goal: I have an EtherCAT topology issue which normally a "Scan for devices.." on the EtherCAT master would shed some light on. Issue: Upon trying such I get a "No gateway selected" error. Question: How might I point the the "scanner" at a gateway? What is working: Gateway is running in system tray. I can go online to PLC. A scan from the "Diagnostics live" tab of the EtherCAT master gives slave status. What I have tried: Restarting gateway in system tray. Exiting system tray gateway and reloading it. Turning off firewall. Contacting ABB support multiple times. Any help appreciated.
Last updated: 2024-05-20
Post by smartcoco on OPC server in "Communication manager"
CODESYS Forge
talk
(Post)
I don't recommend using 'Communication Manager'. Under 'Communication Manager', the 'NodeId' type of OPC UA can only be of type 'OPAQUE'. This will bring compatibility issues to the development of the upper computer.
Last updated: 2025-01-24
Post by damian177 on CM4S GPIO's in Codesys
CODESYS Forge
talk
(Post)
Hi, I am running my application on device based on Compute Module 4S (Cortex-A72 (ARMv8) 64-bit ). On this device I installed RPi Runtime in 4.11.0.0 version. In my project I use device: Codesys Control for Raspberry Pi 64SL and my project works, but I actually do not have acces to all GPIO's , because GPIOs Compute Module is available only in 3.5.16.0 version and it doesn't work. Properly work GPIOs B+/Pi2 but using this device I do not have acces to all GPIO's in CM4S. Anyone of can tell me how add GPIOs Compute Module 4.11.0.0 to my project ?
Last updated: 2024-05-28
Post by timvh on Device diagnosis ( EtherCAT IO card )
CODESYS Forge
talk
(Post)
You can get the state by just using the name of your node (same name as in device tree): VAR etcState: IoDrvEthercatDriverLib.ETC_SLAVE_STATE; END_VAR etcState := EJ1100.wState; Alternatively, you can iterate through the device tree to get the status of all (Ethercat) nodes. See here an example (no guarantee it works, just give as suggestion): PROGRAM P_IO_State VAR CONSTANT uiMAX_NR_OF_TERMINALS : UINT := 100; END_VAR VAR // general device diagnosis // can only be used when the Device - PLC Settings - Advanced settings - enable diagnosis for devices is enabled // this will add the DED library coupler: DED.INode; terminal: DED.INode; aDeviceState: ARRAY[0..uiMAX_NR_OF_TERMINALS - 1] OF DED.DEVICE_STATE; uiTerminalCount : UINT; uiIndex : UINT; // for each terminal check if it implements device diagnostics xQueryResult: BOOL; itfDevice : DED.IDevice2; xDiagAvailable: BOOL; eError: DED.ERROR; xEverythingOK: BOOL; END_VAR uiTerminalCount := 0; // start at the top of the device tree with the first EtherCAT coupler coupler := EtherCAT_Master.FirstChildNode; WHILE coupler <> 0 DO // for each coupler that is found start at the first terminal terminal := coupler.FirstChildNode; WHILE terminal <> 0 AND uiTerminalCount < uiMAX_NR_OF_TERMINALS - 1 DO // for each terminal that is found get the status through the device diagnosis interface xQueryResult := __QUERYINTERFACE(terminal, itfDevice); IF xQueryResult THEN aDeviceState[uiTerminalCount] := itfDevice.GetDeviceState(xDiagnosisInfoAvailable => xDiagAvailable, eError => eError); uiTerminalCount := uiTerminalCount + 1; END_IF terminal := terminal.NextSiblingNode; END_WHILE coupler := coupler.NextSiblingNode; END_WHILE uiIndex := 0; xEverythingOK := TRUE; WHILE uiIndex < uiTerminalCount DO IF aDeviceState[uiIndex] <> DED.DEVICE_STATE.RUNNING THEN xEverythingOK := FALSE; EXIT; END_IF uiIndex := uiIndex + 1; END_WHILE
Last updated: 2025-02-06
Post by psychoengineer on Cannot Save CSV File on Windows Computer Using CODESYS and Control Win
CODESYS Forge
talk
(Post)
I am currently working on a project using CODESYS and Control Win on a Windows computer. I've encountered an issue where I am unable to save a CSV file. I have followed the standard procedures and used the appropriate file handling functions, but the file is not being created or saved as expected. IF xStartTest THEN sFileName := '\logs.txt'; sFileName := CONCAT(gvl.g_sMainDirectory, sFileName); sFileNameCopy := '\CAAFileCopy.txt'; sFileNameCopy := CONCAT(gvl.g_sMainDirectory, sFileNameCopy); //eWriteState := FILE_OPEN_TRIGGER; xTestDone := FALSE; xError := FALSE; xStartTest := FALSE; END_IF VAR_GLOBAL g_sMainDirectory : STRING := 'C:\LogFiles'; // file path for CSV file END_VAR Despite this, the file does not appear in the specified directory, and no error messages are being generated. I've checked the directory permissions and ensured that the path is correct. Has anyone else experienced a similar issue or have any suggestions on how to resolve this? Any help would be greatly appreciated. Thank you!
Last updated: 2024-07-04
Post by jzhvymetal77 on IecVarAccessLibrary.IBaseTreeNode methon
CODESYS Forge
talk
(Post)
I got this code working again. 3S/CoDeSys, your level of obfuscation and lack of documentation turns a simple task into a monumental complex challenge. The issue was that at some point the IecVarAccessLibrary changed and no longer allowed using IBaseTreeNode to retrieve a child or the number of children. The attached code has been updated to use IIecVarAccess6.VarAccBrowseGetChildByIndex instead. The code was also cleaned up but is still a work in progress. The current example only works one layer deep. This means native data types, arrays, and single-layer structures are supported. However, structure arrays and nested structures are not yet supported.
Last updated: 2025-08-25
Post by chris12345 on OPC UA datasource low read frequency
CODESYS Forge
talk
(Post)
Hi yr00, the default sampling interval is set to 1s. you can generate your own client settings, this link should help you:- https://content.helpme-codesys.com/en/CODESYS%20Communication/_comm_use_dynamic_opc_ua_server_comm_settings.html
Last updated: 2023-09-13
Post by chris12345 on OPC UA datasource low read frequency
CODESYS Forge
talk
(Post)
Hi yr00, the default sampling interval is set to 1s. you can generate your own client settings, this link should help you:- https://content.helpme-codesys.com/en/CODESYS%20Communication/_comm_use_dynamic_opc_ua_server_comm_settings.html
Last updated: 2023-09-13
Post by murdemon on CNC Jumps G20 - SMC_NCInterpreter and long time to process
CODESYS Forge
talk
(Post)
Best way.. in CNC program before G20 jump, set G75. And for fbCheckVel execute if fbInterpreter.bWorking AND fbInterpreter.bLastObjectWasAdministrative; and same for Interpolator. " ..... dumm := fbInterpreter.bWorking AND fbInterpreter.bLastObjectWasAdministrative; //Check velociteses. fbCheckVel(bExecute := (fbInterpreter.bDone or) dumm, bAbort := gCNC.bCycleStop, poqDataIn := fbInterpreter.poqDataOut); "
Last updated: 2024-08-03
Post by dennisyhli on Ethernet IP Connection timeout
CODESYS Forge
talk
(Post)
I use ethernet ip scanner and the connection type is set to multicast. After running the PLC, the ethernet IP will have a connection timeout every 10 seconds. What is the reason for this error?
Last updated: 2024-08-16
Post by i-campbell on MODBUS TCP REGISTERS CODESYS V3.5
CODESYS Forge
talk
(Post)
codesys is in hex and starts at 0 your other program is set to decimal and maybe starts at 0 or 1, I can't tell.
Last updated: 2024-10-12
Post by bingo on PLC Shell commands via ST Code
CODESYS Forge
talk
(Post)
For a permanent change, you may need to update the PLC configuration file or set the IP at startup using retained variables.
Last updated: 2025-03-02
Post by snhatton on Visu - changing auto-logout time
CODESYS Forge
talk
(Post)
You could try using the VUM_UserGroup struct from the VisuUserManagement library. I haven't tried this, but there is a variable for tAutoLogout to set the logout time.
Last updated: 2023-12-11
Post by mxj262 on FB having single input but initialized with Array
CODESYS Forge
talk
(Post)
Ok yes now the loop has stopped when I set sum to zero before the for loop. Why will it retain the sum value from the last call?
Last updated: 2024-05-06
Post by ofey on OPC server crash
CODESYS Forge
talk
(Post)
Hi! I repeatly encounter a crash of the OPC server, which forces a reboot of the controller with frequent connect/disconnect to the server. Have any of you encountered this before? And is it a workaround? ie. deny that particular client connection by timeout or similar instead of crashing the PLC? This is during a development phase of the user interface. Up to 3 others connect/disconnect frequently to test their code. It is a bit troublesome of the PLC crashes several times a day because of this :( I greatly appreciate all comments. I hope it exists a fix for this, or something that hinders the crash. I attached the logfile for the crash
Last updated: 2024-11-26
Post by trusty-squire on Strange problem with the ‘MC_SetPosition’ function
CODESYS Forge
talk
(Post)
Here, it seems to me that we are getting completely off track with the observed problem. If questions clarifying the details of the installation are problematic, it's best to include those details in the original question then... I had already written this elsewhere. The program before being brought into machines was exhaustively tested in SW emulation and the problem did not occur. Testing the full program in emulation is entirely different from creating a simplified program to isolate the function causing problems in the real world. I would recommend trying it to isolate the issue. The drive and motor have been working fine for about 10 years. In replacing the machine control system, I opted for CoDeSys where before there was something else. But this is not the subject of the problem A simple "yes" is the correct answer to my question here... Anyways, you seem to be a very knowledgeable expert, good luck on your problem!
Last updated: 2025-01-18