Post by fontrap on cmDongle Raspberry Pi issue
CODESYS Forge
talk
(Post)
Yes 4.11.0.0
Last updated: 2024-04-22
Post by jrsantab on Remote connection to ifm PLC & HMI
CODESYS Forge
talk
(Post)
Last updated: 2024-04-22
Post by stdenits on Set several bits in WORD
CODESYS Forge
talk
(Post)
DEL
Last updated: 2024-04-23
Post by wiresplus on How to display the application name on a visualization (V3.5.16)
CODESYS Forge
talk
(Post)
Hello! I would like to display the project name on the HMI The project name contains the version number That way, a tech knows which version is loaded on the PLC. Is the a standard way to display this, or do I have to hard-code into the HMI (not ideal)?
Last updated: 2024-05-13
Post by plunje on Sensor not set
CODESYS Forge
talk
(Post)
Thanks a lot!
Last updated: 2024-05-28
Post by eschwellinger on Official MQTT-Client: MAX_RECEIVE_BUFFER_SIZE_EXCEEDED
CODESYS Forge
talk
(Post)
here: (SP20)
Last updated: 2024-06-07
Post by mozed on Windows 11 and SP17
CODESYS Forge
talk
(Post)
Last updated: 2024-06-12
Post by andrew-budaiev on Formatting Integer
CODESYS Forge
talk
(Post)
Thanks!
Last updated: 2024-06-17
Post by svenkaro on Codesyscontrol.service stoppt nach 30s
CODESYS Forge
talk
(Post)
sorry, wrong forum.
Last updated: 2024-06-18
Post by kuegerls on SysProcessExecuteCommand2 and CANopen Device
CODESYS Forge
talk
(Post)
4.10.0.0
Last updated: 2024-06-24
Post by kuegerls on SysProcessExecuteCommand2 and CANopen Device
CODESYS Forge
talk
(Post)
4.10.0.0
Last updated: 2024-06-24
Post by fizzy-bubblech on 3.5 P20 hangs - no response
CODESYS Forge
talk
(Post)
Last updated: 2024-06-27
Post by fizzy-bubblech on 3.5 P20 hangs - no response
CODESYS Forge
talk
(Post)
Last updated: 2024-06-27
Post by vtec35 on search runtime 4.9.0.0 for pi 3
CODESYS Forge
talk
(Post)
Last updated: 2025-10-24
Post by faceplant on CmpDynamicText unresolved references
CODESYS Forge
talk
(Post)
Hello! I am new to codesys so I am sorry if this is not the right place to ask this question. I am using codesys V3.5 SP20 Patch 1 + (64-bit) and a Groov EPIC PLC (GRV-EPIC-PR2). I am trying to build and deploy my application to the PLC, but when I log in I get 6 errors (codesys_error.png). It seems that the errors have to do with the CmpDynamicText system library which I have as version 3.5.20.0. I have tried to add CmpDynamicText to the ComponentManager section in the PLC's CODESYSControl.cfg file as described in this forum post and still hit the same error. I noticed that the library is grayed out in the library manager, which I think might be the issue. However I don't remember if it was grayed out before I encountered this issue. Please let me know if I can provide anymore info. Thank you!!!
Last updated: 2024-07-19
Post by mainak on Opaque NodeId in the OPC UA server
CODESYS Forge
talk
(Post)
Hello all, I am using the OPC UA server with my custom information model. I have used the communication manager to add my information model under my application and created instances from OPC UA types. I see that the created instances in the OPC UA server has some opaque nodeid (attached screenshot) and I want to change that. Therefore I have the following questions: 1. Is there a way to configure the NodeIds of instances in the OPC UA server? I tried to edit it using the UaExpert client but got error "BadNotWriteable". is it possible to configure it somewhere so that the nodeids can be changed using an external client? 2. Is there a way to define the rule for creating instance nodeids within the codesys IDE? 3. Is it possible to create the instances before e.g. using a modelling tool like UaModeler and import them as part of the information model and use them later? Using the communication manager, I can only create instances from types. I couldn't find a way to map my existing instances to plc tags from my application. It would be nice if someone could help me with these issues. Thanks in advance. :)
Last updated: 2024-10-19
Post by koerbejm on Probleme beim aktivieren von Lizenzen
CODESYS Forge
talk
(Post)
Liebe Codesys-Gemeinde, ich habe folgendes Problem und bitte um Hilfe: Um eine auf meinem dem Raspberry Pi laufende Steuerung ohne große Mühe duplizieren zu können, habe ich mir ein Image der SD Karte mit Win32 Diskimager erstellt. Dieses konnte ich bisher ohne weitere Probleme auf eine weitere Micro-SD karte ausrollen. Anschließend habe ich mich via Putty auf den PI geschaltet, die vorherige Lizenz (die ja für den vorheringen PI zulässig war) gelöscht über - sudo su - rm -r /var/opt/codesys/cmact_licenses/ - reboot Um dann via Codesys 3.5 SP16 Patch 4 eine neue Lizenznummer ">>Tools>Lizenzmanager>Lizenz aktivieren" zu aktivieren und das wars. Durch die Umstellung des Lizensierungsverfahrens klappt diese Variante nun nicht mehr. Ich habe mir neue Lizenzen von Codesys gekauf, doch sobald ich diese in die Ticket-ID eintrage und aktivieren möchte bekomme ich folgende Fehlermeldung: ReturnCode: 403046401, An internal error has occured. Please try it again later. (siehe Bild im Anhang "Fehler_Codesys3.5V16.png") Ich habe dann meine Codesys-Version auf Version 3.5 SP20 geupdated und das selbe versucht mit dem Resultat, dass ich nun folgende Fehlermeldung erhalte: "Der ausgewählte Container "...." paßt nicht zu Ihrem Ticket. Bitte wählen Sie einen passenden aus." --> Siehe Bild im Anhang "Fehler_Codesys3.5V120.png" Was genau kann/muss ich tun, damit ich einfach wie bisher meine Steuerungen duplizieren kann? Verwendete Hardware: Raspberry Pi 3 Model B+ Verwendete Lizenz: Codesys Control Basic L Viele Grüße und Danke, Jan
Last updated: 2024-10-23
Post by edvard-munch on How I can get "Done flag" for "Modbus Slave Channel"?
CODESYS Forge
talk
(Post)
This is from 10 years ago, I know. But I have been using (SLAVE_DEVICE.iChannelIndex = CHANNEL_NUMBER) AND (SLAVE_DEVICE.xDone) I suppose that it shows xDone for the channel that shows up in the iChannelIndex at the same cycle? It seems to be working properly for two devices that I have been using it before But now I have another device and using two write channels, for one register each. One channel works properly and returns DONE flag When another channel is triggered, I see that it shows up in iChannelIndex, but flag DONE not received, but no Error for the channel. Also, when i check the register in the device it's evident that data has been transferred. Is this could happen sometimes with CODESYS, so DONE flag not received? Or this is a problem with a given device? With this certain register
Last updated: 2024-12-19
Post by jeroenaero on Problem with CodeSys Control SL Deploy Tool 4.15.0.0
CODESYS Forge
talk
(Post)
Hello, We just installed the new version of CodeSys Control SL Deploy Tool 4.15.0.0 but we get the following error when we try to add a VPLC. Can someone of the CodeSys team fix this issue? the object reference is not set to an instance of the object Zie het einde van dit bericht voor meer informatie over het aanroepen van JIT-foutopsporing (Just In Time) in plaats van dit dialoogvenster. ** Tekst van uitzondering ** System.NullReferenceException: De objectverwijzing is niet op een exemplaar van een object ingesteld. bij _3S.CoDeSys.RuntimeDeployTool.Views.AddNewInstanceForm.ShowAllImages() bij _3S.CoDeSys.RuntimeDeployTool.Views.AddNewInstanceForm..ctor(List1 virtualControls, List1 existingNames) bij _3S.CoDeSys.RuntimeDeployTool.Views.MainEditorTab_Operation.OnAddInstanceClick() bij _3S.CoDeSys.RuntimeDeployTool.Views.MainEditorTab_Operation.bt_add_Click(Object sender, EventArgs e) bij System.Windows.Forms.ToolStripItem.RaiseEvent(Object key, EventArgs e) bij System.Windows.Forms.ToolStripButton.OnClick(EventArgs e) bij System.Windows.Forms.ToolStripItem.HandleClick(EventArgs e) bij System.Windows.Forms.ToolStripItem.HandleMouseUp(MouseEventArgs e) bij System.Windows.Forms.ToolStripItem.FireEventInteractive(EventArgs e, ToolStripItemEventType met) bij System.Windows.Forms.ToolStripItem.FireEvent(EventArgs e, ToolStripItemEventType met) bij System.Windows.Forms.ToolStrip.OnMouseUp(MouseEventArgs mea) bij System.Windows.Forms.Control.WmMouseUp(Message& m, MouseButtons button, Int32 clicks) bij System.Windows.Forms.Control.WndProc(Message& m) bij System.Windows.Forms.ScrollableControl.WndProc(Message& m) bij System.Windows.Forms.ToolStrip.WndProc(Message& m) bij System.Windows.Forms.Control.ControlNativeWindow.OnMessage(Message& m) bij System.Windows.Forms.Control.ControlNativeWindow.WndProc(Message& m) bij System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam) ** Geladen assembly's ** mscorlib Assembly-versie: 4.0.0.0 Win32-versie: 4.8.9300.0 built by: NET481REL1LAST_C
Last updated: 2025-04-24
Post by bmatlove on Variable Length Array - Cannot mix variable and fixed length dimensions?
CODESYS Forge
talk
(Post)
Using Codesys 3.5.18.30 I am trying to work with an array of variable length in one dimension, but known in the other dimension. For example, using an array that represents a list of items, each with an attribute profile. I do not know how many items will be in the list, but I know that every item has 5 attributes, like size, weight, etc. Codesys does not seem to be able to accept this. I have referenced Data Type: ARRAY OF documentation page, which is not explicit if variable & fixed length array dimensions can be mixed. In the VAR_IN_OUT scope, I initially tried MY_ARRAY : ARRAY [*, *] OF REAL; which was no problem, of course. I then modified it to MY_ARRAY : ARRAY [*, 1..5] OF REAL; which throws C0006: ', or ]' expected instead of '..' among consequent downstream errors. I then used the Auto Declare -> Array Wizard, which accepted (asterisk)-(asterisk) and 1-5 for 2-dimensional lower and upper bounds. It output: MY_ARRAY: ARRAY[*..*, 1..6] OF INT; which throws the same error stream. What's the deal here? Is this possible?
Last updated: 2025-05-23
Post by laurits on Max lines of code, codesys CNC ?
CODESYS Forge
talk
(Post)
Hi, okay here's the project, it's a modified version of "CNC Example 10: Programming Dynamic CNC Paths", no need for G Code text file (i have also tried with G code text file, same problem) in "PROGRAM PLC_PRG" you can set bStart to true, and the program should start running, go to "PROGRAM CNC" and you can see axis moving. lrXpos := IoConfig_Globals.XAixs.fSetPosition; lrYpos := IoConfig_Globals.YAxis.fSetPosition; Now you can can change the number of movements in the the "PROGRAM PLC_PRG" From this number of movements in "program PLC_PRG" BUF : ARRAY[0..32010] OF SMC_GEOINFO; xp : ARRAY[1..32000] OF REAL; yp : ARRAY[1..32000] OF REAL; to this number to this number of movements BUF : ARRAY[0..132010] OF SMC_GEOINFO; xp : ARRAY[1..132000] OF REAL; yp : ARRAY[1..132000] OF REAL; Now if you start the program again you should see an error in the "sMC_Interpolator: SM3_CNC.SMC_Interpolator;" function block Let me know if you can not get it running.
Last updated: 2025-06-03
Post by pouyavakili on Execute Codesys Tests with python
CODESYS Forge
talk
(Post)
❓ Issue: TestManager Not Available in Python Script (AttributeError) 🙏 Question: Why does project.get_testmanager() not work in scripting, even though Test Manager is installed and licensed, and the script runs in GUI mode? Is there a way to ensure the Test Manager interface is loaded or accessible from the scripting environment? 🧠 Summary: I'm trying to automate test execution using the CODESYS scripting engine (Python) via a script that opens a project, builds the application, and runs tests from a TestRepository.xml. Although the Test Manager works manually in the IDE, it fails when accessed via script with the following error: AttributeError: 'ScriptObject' object has no attribute 'testmanager' 🧪 Test Setup: CODESYS version: 3.5.21.10 Test Manager: Installed and licensed (works in the IDE manually) Project: Contains a test repository, which can be executed via the GUI Script execution method: powershell Start-Process -FilePath "C:\Program Files\CODESYS 3.5.21.10\CODESYS\Common\CODESYS.exe" ` -ArgumentList @( '--profile="CODESYS V3.5 SP21 Patch 1"', '--runscript="C:\Scripts\run_tests.py"' ) -Wait 📜 Script Summary: python project = projects.open(project_path) application = project.active_application application.build() This fails: testmanager = project.get_testmanager() ❗ Problem: Calling project.get_testmanager() or application.testmanager throws an AttributeError, even though the same project and test repository work in the GUI.
Last updated: 2025-07-23
Post by mtho on JSON Utilities - JSON file written with invalid structure
CODESYS Forge
talk
(Post)
I'm using the JSON Utilities SL library to write configurations in my program to a file. I'm generating the JSON data using the builder function block and all appears to work correctly. When I write the jsondata to file, I'm finding that some of the JSON elements are not being written in the right location in the file. Rather than writing they keys under the parent object, they get written outside the root JSON object at the end of the file. If I then try to read the file back into the program, I get an invalid_structure error. I don't get any errors when populating the JSON data or when writing the file. I attached an example of the JSON writer output. The problems begin with key P200. Each P200 should go under MBR1 through MBR3. Among the rest of the keys, they are supposed to be under different parent objects. I am using default values for wsLineBreak and encoding.
Last updated: 2024-03-06
Post by william-blandon on RecipeManCommands.ReloadRecipes
CODESYS Forge
talk
(Post)
Hi Dave. Thanks for your answer. I still struggling with this. I have done everything according with the Codesys help even I have looked in detail at the example. I have double checked the recipe manager configuration and the use of all the methods. There are two methods that do not work as expected. I'm using Codesys 3.5.19.20 and recipe management 4.4.0.0 .CreateRecipe just create a recipe in the recipe definition but do not create the file. This have a walk around just giving a .ReadAndSaveRecipe afterwards. .ReloadRecipes do nothing but do not generate any error as well. After calling it I call the .GetRecipeCount and the number is always 0. When I create a new recipe (using the function block methods) then the number changes. Looks like this method is looking to the wrong directory finding nothing. I don't know if there is a missing configuration in the CODESYSControl.cfg file. I'm thinking in a walk around for this but I need to create a strings array with the recipe names as retentive and making all the management when deleting and adding recipes. Have had some one the same problem?
Last updated: 2024-05-23
Post by gatto on Backtick identifiers
CODESYS Forge
talk
(Post)
Hello, I’m in Codesys 3.5.20.40 and I try to declare the variable ´var1´ but I get an error. here : https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_rules.html i read : Backtick identifiers By using backticks, characters can also be used in identifiers that are not normally permitted in identifiers, such as special characters. The acute accent character is used for backticks: ´ (Unicode: U+02CA) The use of backticks is recommended in order to be able to use the same identifiers in CODESYS as in other programming languages or documents, such as circuit diagrams. Any character may be used between two backticks, except line breaks and other backticks. Keywords are also allowed as identifiers between backticks. Examples: ´Variable+9´ ´INT´ The backticks are part of each identifier and therefore var1 and ´var1´ are two different identifiers. Example PROGRAM PLC_PRG VAR var1 : INT; ´var1´: INT; END_VAR var1 := var1 + 1; ´var1´ := 12; Are there any limitations or is something missing in my development environment?
Last updated: 2025-10-28