Search talk: adding a device

 
<< < 1 .. 105 106 107 108 109 .. 186 > >> (Page 107 of 186)

Post by toby on Ethercat Servo Setup CODESYS Forge talk (Post)
Hi everyone, so a little update to this, I've come back to this project in the new year, and got it working. Yeah!, However, now with the new licensing setup, I need a new SoftMotion license, but it doesn't seem to be compatible with the previous Raspberry Pi SL license. Has anyone had any luck with Raspberry Pi and SoftMotion_Lite? Specifically the licensing of such? My customers new installation needs to be rebooted every 30min which is causing headaches! Another option is to not use the SoftMotion function blocks, and control the EtherCat amplifier directly, but I'm not sure how to do so. Does anyone have a specific example project of how to control a servo without the use of the SoftMotion function blocks? Thanks everyone for any assistance rendered. It's very much appreciated! Toby
Last updated: 2024-01-10

Post by eschwellinger on SM Drive license error CODESYS Forge talk (Post)
goto the licensing metrix tab in CODESYS an check which license ...or send us a screenshot of it here
Last updated: 2024-01-10

Post by jbarrio on v3.5 SP19 - Modbus TCP Devices - Channel Limit? CODESYS Forge talk (Post)
Also, this solution is not valid for the RTU, I imagine that this bug should be a high priority...
Last updated: 2024-01-22

Post by masmith1553 on HMI Pushbutton/Move Instruction CODESYS Forge talk (Post)
All your ACT values in the PID blocks are are not valid with a NaN.
Last updated: 2024-01-25

Post by athuum on DataSource not working CODESYS Forge talk (Post)
Hi, I am experiencing the same issue. Have you been able to find a solution?
Last updated: 2024-01-30

Post by eschwellinger on Access to the path *** is denied CODESYS Forge talk (Post)
it is textlist related as far as I remember, let me check if the is a workaround.
Last updated: 2024-02-02

Post by patch914 on Constant error in logs "SysEthernetGetPortConfigAndStatus: Adapter Not Found" CODESYS Forge talk (Post)
Did you find a solution for this? I am seeing the same errors.
Last updated: 2024-02-05

Post by eschwellinger on Data Transferring between 2 PLCs in a same PC CODESYS Forge talk (Post)
.. this will not work on the same pc
Last updated: 2024-02-06

Post by dkugler on Toggling Visualizations using HMI Physical Buttons CODESYS Forge talk (Post)
the magic option is named "Use CurrentVisu variable" activate this option in the Visualization Manager an have a look: https://help.codesys.com/webapp/_visu_obj_manager;product=core_visualization;version=3.5.14.0 if your button is pressed, "feed" the string varable VisuElems.CurrentVisu := 'visu1'; with the correct name of the depending visu. alternative: place a frame element at a empty main visu, konfigure all visus to be shown by this frame. With setting the switching variable of the frame to the index value of the depending visu, it will switch to it. Advantage: the visu names are not hardcoded as string in the ladder lodgic. Good luck! Hint: If you have multiple VisuClients(Target, WebVisu,...) all will show the same visu. Independent switching is much more difficult, but there is a example from codesys.
Last updated: 2024-02-13

Post by nmcc on Toggling Visualizations using HMI Physical Buttons CODESYS Forge talk (Post)
Here is a screenshot. I really do not know how to format the variable exchange you are talking about.
Last updated: 2024-02-13

Post by nmcc on Toggling Visualizations using HMI Physical Buttons CODESYS Forge talk (Post)
Here is a screenshot. I really do not know how to format the variable exchange you are talking about.
Last updated: 2024-02-13

Post by rmaas on Direct Pointers in IOMapping for EtherCAT with IoDrvEthercatLib.ETCSlave_Dia CODESYS Forge talk (Post)
Wow, this is next level for me, very impressive! glad you found a solution, thanks for sharing!
Last updated: 2024-02-13

Post by tokamk on Dynamic setting of the modbus tcp/ip slave ip address CODESYS Forge talk (Post)
Hello, I'm working on a project which includes Panel-PC which communicates with a PLC through Modbus TCP/IP. On the PLC I have a CODESYS code which has Modbus slave objects. The Modbus slave objects have to have manually set IP address in order for them to work properly and the Ip address has to be the PC-Panels's IP. This project is going to a customer and they're using their own IP address realm. So, my question is that is it possible to configure these slaves in some other way, so that the customer doesn't need to modify the CODESYS project? I was thinking that would it be possible to set the IP address of these slaves from external source?
Last updated: 2024-02-15

Post by reinier-geers on Missing Font CODESYS Forge talk (Post)
Im trobles with version 18. Alraedy made a topic. But now i made it new. Some howe i miss the font
Last updated: 2024-02-26

Post by nmcc on Viewing PDF in WebBrowser Visual Element CODESYS Forge talk (Post)
I am trying to show a PDF in a WebBrowser element. I have the file saved to the drive of the HMI/PLC. I am linking it in the URL parameter of the WebBrowser using the following directory link. 'http://localhost:8080/$$sdcard$$/FileName.pdf'. This allows for the program to download without any errors. When I navigate to that screen it is just a white box and nothing shows. I attempted putting the same link in the show parameter and I get a loading icon on my cursor when monitoring the HMI with my PC. Any help is appreciated. Thank you.
Last updated: 2024-02-29

Post by nmcc on Viewing PDF in WebBrowser Visual Element CODESYS Forge talk (Post)
You can change which browser you use in a webbrowser visual element? if so how do I do that?
Last updated: 2024-03-01

Post by lyngaansns on CODESYS Installer CLI - commands syntax description CODESYS Forge talk (Post)
You can do APInstaller.CLI.exe --installAddOn -? for example for a little bit more information.
Last updated: 2024-03-04

Post by dkugler on Web Browser special tools errors CODESYS Forge talk (Post)
If there is a runtime + webvisu running at the .101 then the link should be: http://192.168.1.101:8080/webvisu.htm
Last updated: 2024-03-06

Post by comingback4u on Memory Address Overlap CODESYS Forge talk (Post)
Hello, We use a controller that comes with a bunch of predefined faults. These faults are considered active and historic. They are a 32 byte array but only take up 26 bytes of data. Because of this the historic faults start at address 26 instead of 31. Active faults variable take up address location 0 to 31. Historic faults variable take up address location 26 to 57. Because of this overlap I get an error that these overlap and it wont allow me to download to my controller. This isn't an issue in 3.5.5.4 but becomes an issue in newer version. Is there a way to turn this off? If I change the address location, the historic faults then become broken without doing some manipulation in the code. The software will build just fine. Thank you for your time.
Last updated: 2024-03-07

Post by androidzz on Json Builder problem? CODESYS Forge talk (Post)
I found my problem. The parentIndex from a new object was not connected to the root parent index
Last updated: 2024-03-11

Post by khaledkhalil on Import OPC UA model to Codesys CODESYS Forge talk (Post)
I have added a models in SiOME which a software to design nodes and add instances. and created a resultant xml file. I tried to import the xml file to Codesys through OPC UA information model Repository the problem i don't know how to view my objects which i have designed. and map it to my PLC to make viewable on my server UaExpert. I watched the tutorial video https://youtu.be/aJhzN3Uk-Do?feature=shared. But it only give you how to add the Information model, and my resultant model doesn't have information type. So how in Codesys i can view a model which i have designed in SiOME and mapped my instances (Objects, Variable or methods) with my Variables in PLC I saw people do it in Tia Portal or other Software, but i have no clue how to do it on CODESYS
Last updated: 2024-03-12

Post by fenicklar on Login problem with FileTransfer on Raspberry Pi 5 CODESYS Forge talk (Post)
Hello everyone, I'm currently trying to set up a FileTransfer function from a Webvisu to my Raspberry Pi 5 on Codesys 3.5 SP 19 Patch 6. I went in the files CODESYSControl.cfg and CODESYSControl_User.cfg and added : [CmpWebServerHandlerV3] AllowFileTransferServices=1 And it seems to be working. However, I cannot access my several Webvisu without putting my login. That's a problem because one of my webvisu is in kiosk mode on the raspberry itself and there is nokeyboard attached, it's just an information screen, but I can't view it. Is there a wey to enable the File Transfer without requiring to login ? Thank you for your time
Last updated: 2024-03-18

Post by eschwellinger on Problems with simulation in Window 10 CODESYS Forge talk (Post)
I would give a try to check the content here: c:\ProgramData\CODESYS\CODESYSControlWinV3x64
Last updated: 2024-03-18

Post by eschwellinger on PFC100 Licensing fails CODESYS Forge talk (Post)
possible to use a newer version? maybe it is /var/opt/codesys/cmact_license in your version
Last updated: 2024-03-19

Post by eschwellinger on Licensing info not available. CODESYS Forge talk (Post)
Currently the CODESYS Control Basic S license is not a network license but it should be, so I guess it doesn't work yet
Last updated: 2024-03-20

<< < 1 .. 105 106 107 108 109 .. 186 > >> (Page 107 of 186)