Search talk: STRING TO ASCII CODE

 
<< < 1 .. 10 11 12 13 14 .. 199 > >> (Page 12 of 199)

problem with unicode string input into text field CODESYS Forge talk (Thread)
problem with unicode string input into text field
Last updated: 2018-11-26

List of string pointed by value in visualization CODESYS Forge talk (Thread)
List of string pointed by value in visualization
Last updated: 2018-01-31

read string from a web site (https) CODESYS Forge talk (Thread)
read string from a web site (https)
Last updated: 2019-08-08

Einen String Wert in einer csv. Datei speichern CODESYS Forge talk (Thread)
Einen String Wert in einer csv. Datei speichern
Last updated: 2011-05-25

reading string from file issue (more than 255 bytes) CODESYS Forge talk (Thread)
reading string from file issue (more than 255 bytes)
Last updated: 2023-08-02

EtherNet/IP Device - Status "Diag string: 'Configure encapsulation Layer'" CODESYS Forge talk (Thread)
EtherNet/IP Device - Status "Diag string: 'Configure encapsulation Layer'"
Last updated: 2022-01-02

NBS.IPv4Address.SetInitialValue input should not be STRING(15) CODESYS Forge talk (Thread)
NBS.IPv4Address.SetInitialValue input should not be STRING(15)
Last updated: 2022-12-12

Is there a string compare function in ST ? CODESYS Forge talk (Thread)
Is there a string compare function in ST ?
Last updated: 2017-11-08

XML-String an SOAP-Server mit HttpClient CODESYS Forge talk (Thread)
XML-String an SOAP-Server mit HttpClient
Last updated: 2018-11-23

Extract a memory adress from a string value CODESYS Forge talk (Thread)
Extract a memory adress from a string value
Last updated: 2016-12-06

Return value from a tag given a string literal CODESYS Forge talk (Thread)
Return value from a tag given a string literal
Last updated: 2024-08-13

Post by struccc on HTML5 Controls - string(>80) values CODESYS Forge talk (Post)
Dear all, does anyone have experience with HTML5 controls recently? CODESYS 3.5.20.30 / Visualization 4.6.0.0 I'd like to create a simple lightweight text editor, with proper multiline handling, cut & paste, scrolling, etc. And it seems to work fine, just have problems with strings longer than 80 bytes.... Declaring a variable sText1 : STRING(8000) and referencing it in the HTML5 Controls corresponding value property works perfectly one way: the code receive the data as a string (See log1)... (Note TypeID 1000...) Also sending back the data (seems to work (See log2) except it doesn't change the value of the bound variable. Probably the issue is with using SendSimpleValue method... Naturally, I could do a workaround, but maybe there is a more standard way to implement this... Please let me know if you have any suggestions.
Last updated: 2024-10-23

Post by talhaali on Adding a variable from text list into ST code CODESYS Forge talk (Post)
Hi, can I use a entry of a text list as variable in structured text? for example in attach picture, if i use want to use data of first row. I am trying to write: A : STRING := TextList.Default.0; but it is not workings
Last updated: 2023-12-07

Post by talhaali on Adding a variable from text list into ST code CODESYS Forge talk (Post)
Hi, can I use a entry of a text list as variable in structured text? for example in attach picture, if i want to use data of first row. I am trying to write: A : STRING := TextList.Default.0; but it is not workings
Last updated: 2023-12-07

Post by alez on CANOpen SDO to write VISIBLE STRING CODESYS Forge talk (Post)
Hello, I am experiencing difficulties in configuring a CANopen device by sending SDOs. In particular I am attempting to write an Object Dictionary that has VISIBLE STRING as the Data Type. When I try to configure the sending of an SDO from Codesys to configure this parameter I am not allowed to enter a string value. In my particular case I am trying to change the Manufacturer Device Name ( Index 0x1008 ). Could it be that Codesys doesn't manage these types of variables?
Last updated: 2024-04-29

Post by peterned on Array to String CODESYS Forge talk (Post)
max. string length in Codesys is 255 chars. It's not possible to cram 20,000 things in a string. If you need to send the data to another device, send the whole data[] array (as byte array, without doing anything to it) and extract the information on the other end. As each struct member has a fixed size (81 bytes, as per you declaration), this will be easy. To save some resources, consider declaring string lengths - e.g. if the max possible length for key is 10 chars, declare it key: STRING(10); and it will occupy 11 bytes instead of 81
Last updated: 2024-07-20

Post by drml on Array to String CODESYS Forge talk (Post)
If a size is not specified, CODESYS allocates 80 characters by default for a string. After 7 seconds, does your Json_string contain all of your 20000 key/values? Or is the result truncated to 80 characters?
Last updated: 2024-07-19

Post by mmpl on Array to String CODESYS Forge talk (Post)
Hi Thank you for you reply. Yes I can concatenat longer string. I am using string_Util_Intern libraray for concat. The issue is abot plc performance. It takes 7 second. I am looking to improve time.
Last updated: 2024-07-23

Post by installwhat on How to access to variable value through symbolic string name CODESYS Forge talk (Post)
https://help.codesys.com/api-content/2/codesys/3.5.12.0/en/_cds_operator_string_to/ Something like this?
Last updated: 2024-06-13

Post by installwhat on How to access to variable value through symbolic string name CODESYS Forge talk (Post)
https://help.codesys.com/api-content/2/codesys/3.5.12.0/en/_cds_operator_string_to/ Something like this?
Last updated: 2024-06-13

Post by vladimirsmall on Send data to USB CODESYS Forge talk (Post)
Hello/ Need send some file ( for example Array of string) to USB. Which library need used for this. Thank you
Last updated: 2024-07-20

Post by gustavocsw on MQTT memory leak problem CODESYS Forge talk (Post)
Hello everyone, I'm using the IoT Library to implement the MQTT communication with my local broker server in order to publish and subscribe at specifics topics to share and consume information about my application. But, it seems that are occurring some memory leak problem in a "high" frequency (more than 10 Hz) subscribe process. I follow the same method as in IoT Lib exemples, and at first looks perfect but my PLC was rebooting frequently and when I check its memory usage that was increasing as fast as the subscribe massage was sent. I'm using a WEG PLC410 and a WEG PLC500, and this error occurred in both of them (including in CODESYS Control Win x64). The application sends to the system a message JSON with the float payload Ex. {"data" : 0.8500}, but this happens with a INT, or BOL as well. I use the follow code in my application to find the value: //FindFirstValueByKey VARs PROGRAM JSON_VELO VAR //------Setting the JSON Subscriber to Set the Relay Value jsonDataVelo : JSON.JSONData; jsonByteArrayReaderVelo : JSON.JSONByteArrayReader; xST1okVelo : BOOL; FindFirstValueByKeyVelo : JSON.FindFirstValueByKey; jsonElementVelo : JSON.JSONElement; xDoneReaderVelo : BOOL; xDoneFindVelo : BOOL; //STRING and WSTRING for Subscribe the massage sPayloadJsonVelo : STRING := 'opa'; psPayloadJsonVelo : POINTER TO BYTE := ADR(sPayloadJsonVelo); //wsPayloadJsonRelaySet : WSTRING := "opa"; wsPayloadJsonVelo : WSTRING := STRING_TO_WSTRING('opa'); pwsPayloadJsonVelo : POINTER TO WORD := ADR(wsPayloadJsonVelo); lrVelo : LREAL; xKeepAliveVelo : BOOL; xSetVelo : BOOL; RSSet : RS; LIMPAR : STRING; //Find the msg end sFindVelo : STRING := '}'; psFindVelo : POINTER TO STRING := ADR(sFindVelo); iLenVelo : INT; iSizeVelo : INT := 12; udiContMsg : UDINT; END_VAR // FindFirstValueByKey CODE // Relay Set configuration xSetVelo := MQTT_SUBSCRIBER.RSVelo.Q1; IF xSetVelo THEN xKeepAliveVelo := TRUE; END_IF IF xKeepAliveVelo THEN udiContMsg := udiContMsg + 1; iLenVelo := TO_INT(StrLenA(psPayloadJsonVelo)); iSizeVelo := iLenVelo - TO_INT(MQTT_SUBSCRIBER.udiPayloadSizeVelo); StrDeleteA(psPayloadJsonVelo,iSizeVelo,iLenVelo); wsPayloadJsonVelo := STRING_TO_WSTRING(sPayloadJsonVelo); pwsPayloadJsonVelo := ADR(wsPayloadJsonVelo); //MQTT.ConvertUTF8toUTF16(sourceStart:= ADR(sPayloadJsonVelo), targetStart:= ADR(wsPayloadJsonVelo), dwTargetBufferSize:= TAM, bStrictConversion:= 1); //Reset jsonByteArrayReader jsonByteArrayReaderVelo ( xExecute := TRUE, pwData := pwsPayloadJsonVelo, jsonData := jsonDataVelo, xDone => xDoneReaderVelo ); FindFirstValueByKeyVelo( xExecute := xDoneReaderVelo, wsKey := "data", diStartIndex:= 0, jsonData := jsonDataVelo, jsonElement => jsonElementVelo, xDone => xDoneFindVelo ); IF xDoneFindVelo THEN lrVelo := jsonElementVelo.value.lrValue; //Reset jsonByteArrayReader jsonByteArrayReaderVelo ( xExecute := FALSE, pwData := pwsPayloadJsonVelo, jsonData := jsonDataVelo, xDone => xDoneReaderVelo ); FindFirstValueByKeyVelo( xExecute := FALSE, wsKey := "data", diStartIndex:= 1, jsonData := jsonDataVelo, jsonElement => jsonElementVelo, xDone => xDoneFindVelo ); xKeepAliveVelo := FALSE; GVL.xSetVeloRead := TRUE; END_IF END_IF And this to subscribe at the topic: //SUBSCRIBE VAR: //----------------- Subscribe Velocity ----------------------- MQTTSubscribeVelo : MQTT.MQTTSubscribe;//Variable MQTTSubscriber block -X - function-X wsTopicSubscribeVelo : WSTRING(1024) := "CORE/odometry/GET/data/simp"; // Topic to publish a message sSubscribeMassageVelo : STRING; udiPayloadSizeVelo : UDINT; xSDoneVelo : BOOL; xSErrorVelo : BOOL; xReceiveVelo : BOOL; eSTypeVelo : MQTT.MQTT_ERROR; eSMQTTErrorVelo : MQTT.MQTT_ERROR; RSVelo : RS; udiCont : UDINT; //SUBSCRIBE CODE: MQTTSubscribeVelo( xEnable:= MQTT_CLIENT.xConnection_Broker AND NOT xSErrorVelo AND NOT JSON_VELO.xKeepAliveVelo, pbPayload:= JSON_VELO.psPayloadJsonVelo, udiMaxPayloadSize:= SIZEOF(JSON_VELO.sPayloadJsonVelo), udiPayloadSize => udiPayloadSizeVelo, mqttClient:= MQTT_CLIENT.ClientMQTT, wsTopicFilter:=wsTopicSubscribeVelo, xDone => xSDoneVelo, xError=> xSErrorVelo, xReceived => xReceiveVelo, eMQTTError=> eSMQTTErrorVelo ); RSVelo(SET := xReceiveVelo, RESET1 := JSON_VELO.xKeepAliveVelo);
Last updated: 2024-09-09

Post by dkugler on I want to convert a WORD to a hex string like 15.432 to '3C48' CODESYS Forge talk (Post)
you try to convert a WORD with BYTE_TO_HEX directly? Using https://de.helpme-codesys.com/ lead to the SM3_shared lib. There is a function: https://content.helpme-codesys.com/en/libs/SM3_Shared/Current/SM3_Shared/StringFormat/Word_To_HexString.html
Last updated: 2024-04-19

Post by simover on TCP/IP client CODESYS Forge talk (Post)
I want to send a string to a tics TCP/IP server. I got i working with the Net Base lib. for communication good with this tcis i need to by array of byte I want to include a string in the third position of the array TCIS_Send[1] :=254; //this valus is fix for evry communication TCIS_Send[2] :=80; //this valus is fix for evry communication TCIS_Send[3] := ; here I put my and my string is lik this 5806509-DRAP10#AB#3452302073 TCIS_Send[4] :=252; //this valus is fix for evry communication
Last updated: 2023-12-18

can I share compiled code? CODESYS Forge talk (Thread)
can I share compiled code?
Last updated: 2016-07-25

<< < 1 .. 10 11 12 13 14 .. 199 > >> (Page 12 of 199)

Showing results of 4959

Sort by relevance or date