Post by egau on Mutate Hash table value CODESYS Forge talk (Post)
Hi, using the ElementCollections Library, why isn't it possible to mutate a value found within a HashTable? From what I understand, the only way to change a value would be to use the RemoveByKey(), followed by AddKeyValuePair(). My goal is to use a Data Structure that works like a Dictionary in Python. The HashTable seems to come close to this, except that the values themselves seem to be immutable... In python, we can mutate a dict easily (see attached picture).
Last updated: 2024-08-29

How to check whether one input is assigned a value? CODESYS Forge talk (Thread)
How to check whether one input is assigned a value?
Last updated: 2008-01-15

Several py file share one external file to get some default value CODESYS Forge talk (Thread)
Several py file share one external file to get some default value
Last updated: 2019-12-12

Reading value of whole struct variable at online mode by script CODESYS Forge talk (Thread)
Reading value of whole struct variable at online mode by script
Last updated: 2020-04-05

Is it possible to send a real value close to 0 through modbus? CODESYS Forge talk (Thread)
Is it possible to send a real value close to 0 through modbus?
Last updated: 2023-02-25

Call python script for codesys from powershell and read return value CODESYS Forge talk (Thread)
Call python script for codesys from powershell and read return value
Last updated: 2020-07-30

Test Manager - Having a user value persist from one execution to the next CODESYS Forge talk (Thread)
Test Manager - Having a user value persist from one execution to the next
Last updated: 2023-05-08

raspberry pi as PLC all GPIO input pins are TRUE value CODESYS Forge talk (Thread)
raspberry pi as PLC all GPIO input pins are TRUE value
Last updated: 2020-10-29

Can't figure out how to "save" a value of a variable CODESYS Forge talk (Thread)
Can't figure out how to "save" a value of a variable
Last updated: 2017-02-19

CANopen Manager on TURCK PLC sends PDO only on value change CODESYS Forge talk (Thread)
CANopen Manager on TURCK PLC sends PDO only on value change
Last updated: 2023-06-30

Code for reading 4 address to get 1 value of sensor (Ethernet IP) CODESYS Forge talk (Thread)
Code for reading 4 address to get 1 value of sensor (Ethernet IP)
Last updated: 2024-05-06

RAMP_REAL FB is retaining my output value when i try to re use the FB CODESYS Forge talk (Thread)
RAMP_REAL FB is retaining my output value when i try to re use the FB
Last updated: 2024-07-29

Post by kims2024 on Timer change online CODESYS Forge talk (Post)
with codesys v2.3, I want to extend a timer value online. I have tried the value does not go !
Last updated: 2024-08-24

Post by alexgooi on Modbus writing on value change CODESYS Forge talk (Post)
The way I usally tackle this is by syncing only words (then you are able to use the FB above). If you then want to write a Boolean simply type it like this. Value[1].0 := Bool1; Value[1].1 := Bool2; Value[1].2 := Bool3; Uints have the same number of bits than a INT/WORD so these ones will work as well (they are only represented diffrently). A Real will work but you will loose some infomration in the conversion. If you want to keep the information you can convert 2 words to a float with a function (for example with the IEEE-754 standard) . In this way the syncing to the server is very simple and in the Codesys Program you decide what part of the word you want to use.
Last updated: 2024-04-03

Post by hjohnson123 on Automatically selecting a visualization element CODESYS Forge talk (Post)
I'm looking to automatically select a text field element in my visualization. I'm not sure if this is possible, as I don't know how to get the data on specific elements. I am wanting automatic selection of the text field, as I am using a keyboard-input barcode scanner, which should always input the barcode into the text field whenever a barcode is scanned. Does anyone know if this can be done?
Last updated: 2024-05-21

Post by ryusoup on JSONByteArrayWriter problem? CODESYS Forge talk (Post)
Hello, I am trying to implement a FB to make JSON formatted WSTRING type message using JSON Utilities 1.9.0.0 included in the IIoT library. In my case, I want to set some objects or arrays and set values to them later. But when I wrote as the sample below, // init builder builder(pJsonData:=pJsonData, diRootObj=>diRootObj); // set the 1st key to root diKey1 := builder.SetKeyWithArray(wsKey:="key1", diParentIndex:=diRootObj, eError=>eError); // set a value to the 1st key wsValue:="value01"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey1, eError=>eError); // set the 2nd key to root diKey2 := builder.SetKeyWithArray(wsKey:="key2", diParentIndex:=diRootObj, eError=>eError); // set a value to the 2nd key wsValue:="value02"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey2, eError=>eError); // set a value to the 1st key again wsValue:="value03"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey1, eError=>eError); // set a value to the 2nd key again wsValue:="value04"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey2, eError=>eError); // write build result writer(xExecute:=TRUE, pwData:=ADR(wsResult), udiSize:=SIZEOF(wsResult), xAsyncMode:=FALSE, jsonData:=pJsonData^); the result was: { "key1": ["value01"], "key2": ["value02", "value03", "value04"] } while my expection was: { "key1": ["value01", "value03"], "key2": ["value02", "value04"] } Inspecting pJsonData^, JSONData itself seems to be ok, so I believe the issue is something caused by the writer FB. Does anyone know how to fix it? Thanks,
Last updated: 2023-10-04

Post by nksr on Is using 'en-gb' and 'en-GB' in visuelems.currentlangauge the same? CODESYS Forge talk (Post)
I am currently programming a language switch program. So, the text flickers between 'en-gb' and 'en-GB' in visuelems.currentlangauge and even if I put a breakpoint, it still flickers. Can you please suggest a solution? Thanks
Last updated: 2024-01-31

Post by dkugler on Toggling Visualizations using HMI Physical Buttons CODESYS Forge talk (Post)
learn to program in structured text or CFC and forget this antique ladder logic.. I'm not firm to do that in ladder
Last updated: 2024-02-13

Post by i-campbell on IIOT MQTT Subscription CODESYS Forge talk (Post)
I think it is a similar issue, but different. I saw you use AWS IoT Core. AWS limits you in this - search in page here for text "Subscriptions per connection" it is 50, cannot be changed.
Last updated: 2024-02-20

Post by taqamert on IFM-Sensor ADC READ CODESYS Forge talk (Post)
I have a pressure sensor that measures 0-600 bar and outputs a 0-5V signal, but my PLC reads analog inputs in the 0-10V range and displays a value of 1024 when 10V is applied. In this case, when the sensor outputs 5V at 600 bar, the PLC shows a value of 512. My working range is 0-350 bar, which means the PLC only uses 298 bits in this range, significantly reducing the resolution. What can I do to achieve better resolution within the 0-350 bar range?
Last updated: 2024-08-23

Post by taqamert on IFM-Sensor ADC READ CODESYS Forge talk (Post)
I have a pressure sensor that measures 0-600 bar and outputs a 0-5V signal, but my PLC reads analog inputs in the 0-10V range and displays a value of 1024 when 10V is applied. In this case, when the sensor outputs 5V at 600 bar, the PLC shows a value of 512. My working range is 0-350 bar, which means the PLC only uses 298 bits in this range, significantly reducing the resolution. What can I do to achieve better resolution within the 0-350 bar range?
Last updated: 2024-08-23

Post by taqamert on IFM-Sensor ADC READ CODESYS Forge talk (Post)
I have a pressure sensor that measures 0-600 bar and outputs a 0-5V signal, but my PLC reads analog inputs in the 0-10V range and displays a value of 1024 when 10V is applied. In this case, when the sensor outputs 5V at 600 bar, the PLC shows a value of 512. My working range is 0-350 bar, which means the PLC only uses 298 bits in this range, significantly reducing the resolution. What can I do to achieve better resolution within the 0-350 bar range?
Last updated: 2024-08-23

Post by irshad on Modbus TCP/IP slave communication errow CODESYS Forge talk (Post)
While reading the value of a slave device, it shows error frequently and i need to restart my PLC for getting the communication back. In codesys it shows the slave in Red color with error status. How to solve the above
Last updated: 2024-02-03

Post by mibkid17 on Ethernet Adapter message: Adapter configured. Open all connections CODESYS Forge talk (Post)
Trying to control 525 with codsys the info from C-4 section. i should input the value in user defined parameters? in the generic device
Last updated: 2024-04-09

Ãœbertragen von Symbolnamen in Steuerkonfiguartion in ... CODESYS Forge talk (Thread)
Ãœbertragen von Symbolnamen in Steuerkonfiguartion in ...
Last updated: 2011-05-15