Post by ryandmg on Web Client (HMI) Disconnects from Webvisu (Weidmuller u-OS) CODESYS Forge talk (Post)
Thanks So Much for the reply! Were using the Weidmuller UV66-ADV-10-CAP-W The HMI is pointed to the URL which is assigned through u-OS. Basically when you log into the controller's webserver via browser you can view the installed apps. One of which is the Codesys runtime. When you click on that it takes you to the visualization. That corresponding url is what the HMI is looking for. I apologize I don't have that on hand as I'm in the office right now. I don't think I tried connecting using the port you mentioned and https in lieu of the u_OS URL. I can certainly try. Out of the box the u-OS is set for HTTP. Since we're isolated I havent changed that yet. When this has happened while logged on via chrome on my laptop, simply refreshing brings the visualization right back. In the case of the HMI in kiosk mode, we power cycle the HMI to force a reconnect, log back in u-OS and the visualization is back.
Last updated: 2023-09-06

Post by biiebs on Aufbau von Ablaufsteuerungen ermitteln CODESYS Forge talk (Post)
Hallo Zusammen, gibt es in CODESYS bei Ablaufsteuerungen weitere Möglichkeiten außer den AS-Einstellungen z.B. die Aufbaustruktur der Ablaufsteuerung herauszufinden? Gesamtanzahl der verwendeten Aktionen / Schritte - Im besten Fall auch die einzelnen Verzweigungen? Ich würde den gesamten Aufbau der Schrittkette gerne als "View" in einer übergeordneten Software abbilden lassen, da sich die Ablaufsteuerungen, je nach Projekt im Aufbau unterscheiden bräuchte ich die Kenntniss über den Aufbau dieser Schrittketten. Oder müsste ich mir hier einen "Workaround" programmieren, der z.B. bei Init erstmal den Aufbau der Ablaufsteuerung durchläuft und mir die nötigen Informationen liefert? Natürlich wäre auch ein Weg den Aufbau des AS-Bausteins über die PLCopen XML zu exportieren, jedoch müsste dies bei Änderungen jeweils nachgezogen werden - was etwas unschön wäre, falls dies vergessen würde. Mittlerweile habe ich auch das Tool "SFC Visu Generator" gefunden, dessen Funktion im Prinzip genau das darstellt, was ich benötige - jedoch leider nur als CODESYS interne Visualisierung. Ich würde den Export des Bausteins gerne in meine übergeordnete Software implementieren. Gibt es hier die Möglichkeit das Vorgehen zu Erfahren oder den vom Baustein generierten Export bei mir zu implementieren? Hat hier jemand sowas ähnliches schonmal gelöst? Vielen Dank im Voraus Mit freundlichen Grüßen Biiebs
Last updated: 2024-07-25

Post by programmierer on Implementing UDP Communication CODESYS Forge talk (Post)
Hello everyone, I hope you can help me with my problem. I am new to programming and am currently working with a WAGO controller in our lab, which controls a heat pump. My goal is to send the electrical power of the heat pump (Pel_WP) via a UDP connection to a specific IP address. I am using Codesys version 2.3 and following the guide I found here: https://forge.codesys.com/forum/de/396/genmed-Konfiguration%20der%20UDP%20Kommunikation%20Cosesys%20S7.pdf. I have adapted the guide to suit my needs. The data sending works since I can force the reception value Pel_WP and the data is sent accordingly. However, I am having trouble with the receiving part. The reception value is not being correctly received, and the diSocket variable shows -1. The connection between the heat pump and the WAGO controller seems to be set up correctly, as the heat pump is listed under the communication parameters with the correct IP address. I have also attached images to provide a better view of the setup. I would greatly appreciate any support or suggestions for a solution. Thank you in advance!
Last updated: 2024-08-02

Post by ofey on EtherCAT fieldbus CODESYS Forge talk (Post)
Hi, everyone! I'm trying to set up a PLC controller and a connection to an EtherCAT slave device in Codesys. I want to create a flexible program that I can upload to multiple controllers with different remote IO connected (same program). On one plant i may have 5 AI-cards and 3 DO-cards, and on another I may have 4 AI-cards and 2 DO-cards. For not needing to maintain several different programs wih different devices defined in the program (one for each set up) I thought that using a remote IO would make it easier having a single program. That way I could refer to different memory addresses instead of predefined slots/channels and IO's, that would give me errors if there was a different IO on the plant than what the program expected. When I tried setting up the etherCAT master, I saw that I had to define the etherCAT slave devices with the different IO'cards for me to be able to refer to the memory addresses in a PRG. Exactly what I was trying to avoid. My setup is something like a program that can handle 16 separate pump controls. In a year maybe 6 plans get deployed, and depending on how large the project is, the number of pumps can vary between 4 and 16. And the managers dont want to have IO's for all 16 pumps on every cabinet, and I dont want to maintain 16 separate projects files in case of updates etc. I thought the best way to tackle this was having a single project that read/write data to the different pump IO's by remote IO (fieldbus ethercat) addresses. And the number of pump controls are activated by an external GUI. If pump 1-6 is activated by the GUI, then the PLC-program tries to read/write input/outputs from predefined addresses for the expected IO's. My test setup is a PFC200 WAGO controller and a EtherCAT fieldbus coupler (750-354) with some IO. I hope I didn't explain this too horrible, and if there is a more easy and elegant solution for this challenge I appreciate a feedback on this.
Last updated: 2024-04-08

Post by martinlithlith on Mux I2C CODESYS Forge talk (Post)
Hi! I´ll try to get this thread going again as i´m having simliar problems. Right now i get a red triangle on my connected devices (i´m testing with a BME280 sensor and a PCA9685 resvo driver). The TCA9548 have the green symbol beside it. On the "red" devices i get that the bus is not running. I have tried to either run it using the parent bus cycle setting or creating a new freewheeling task prio 1 but nothing helps. I have compared my settings to the settings from the example from the MUX package and i have read (i think) every thread in forge that could be of interest. EDIT: The ic2detect only shows the mux (70-70) and the servo drive (70-76) so i´ll look in to if i managed to burn the 280-sensor while soldering). Another question regarding the 280 sensor. I have a sensor GY-BM E/P 280 that should record humidity and temperatur. Could this be a problem with the library? Does anyone have an idea of what i might be doing wrong? I have some experience from Codesys but not much so this could be an easy one. All suggestions are welcome. I tried to upload the project archive but it did not work. Should i upload the export or how could i show you my horrible project? Best, Martin
Last updated: 2023-10-22

Post by nizrahel on OpC UA server on Raspberry Pi 64 SL runtime CODESYS Forge talk (Post)
Hi all! I'm working on an home project using a Raspberry Pi 3 device with Codesys for Raspberry Pi 64 SL runtime. I would like to create the HMI interface with Siemens WinCC Unified (or Advanced) configuring the Raspberry as OPC UA server. I tryed everything, but I didn't find the way to let the OPC UA connection works using UaExpert. I tryed to use anonymous connection, authenticated connection and the ip address instead of the server name in the path connection. There is no way to connect to the OPC UA server and I was asking myself if this feature is really supported for the runtime version used. Another strange thing I noted, is that is not possible to quickly create an OPC UA certificate in the Security Screen, as show in any tutorials. I have correctly created the Symbol Configuration enabling the OPC UA feature. I attach to this topic some printscreen of the actual configuration (sorry for the italian language interface, but I didn't find the way to switch to english). Thank you very much in advance for your support and advices!
Last updated: 2023-12-03

Post by aliazzz on Unable to deploy Virtual Control SL on ARM64 (Raspberry Pi5) CODESYS Forge talk (Post)
Hi, I have successfully deployed "Virtual Control SL" on a few x86/64 machines now. However, I'd now like to deploy this to a Raspberry Pi (ARM64). To do this I prepared the Raspberry Pi5 with the following prereq's; * Minimal PREEMPT Debian * Latest Bootfirmware * full SSH access via non-root account * Podman * RedHat Cockpit with CODESYS LicensServer plugin up and running However, I can't seem to resolve copying the correct (deploy) Images as they wont show up in the CODESYS IDE I have added CODESYS Virtual Control for Linux SL and the CODESYS LicenseServer for Linux SL via the CODESYS installer on my DevBox. I open CODESYS > Tools > Deploy Control SL Next I enter the SSH targets IP and Credentials and for my RPi5 and it shows "Connected". In the next tab, Deployment, the dropdown box only shows one (1) image, which also is the incorrect CPU architecture. Only Virtual Control AMDx64 shows up (!?) while I expect to see the ARM64 based images for both Edge and Control. Has someone encountered this too? I'd like to hear other people experiences with Virtual Control deployment on ARM based architecture. attachment 1: AMD64 based deployment pulldown menu (correct images) attachment 2: ARM64 based deployment pulldown menu (incorrect images) regards,
Last updated: 2024-07-28

Post by kleeswi on Visualization scaling problem with B&R T30 panel CODESYS Forge talk (Post)
The probelm arises for the B&R T30 panel after updating Codesys from 3.5.17 to 3.5.19 patch 5. We have to use 3.5.19 for other reasons so we cannot downgrade the version. The scaling problem only exists for the B&R 6PPT30.0702.20F025 panel, the B&R T50 panel and a esa lumia panel work. When we choose a fixed resolution it looks also good, however we also want to support the esa lumia panel with a different resolution. The images show the anisotropic and isotropic option. In the anisotropic option it scales the hight correctly but not the width and in the isotropic option is scales both hight and width false, it also does not start in the top left corner. Does someone have any suggestion why it does not work anymore with the new codesys version and are there workarounds? I added all versions with visualization packages as an image, visuElems is 4.4.0.0.
Last updated: 2024-07-29

Post by abauza on Image Pool using in other libraries CODESYS Forge talk (Post)
Hi im Albert, im developing libraries for my PLCs and i have some issues on visualization part. First of all I have done a library that have a image pool with a list of 4 gifs "ImagePoolErrors" (i've tested in other projects and it works) but the problem comes when i create another library that in the visualization part contains images from my image pool library, when i simulate a program that includes a instance of my second library object the visualization images dont show, any of them, i've checked all the references and tried some options of the image properties but without any difference. Here is the screenshots of the first library (that contains Image Pool) and the second library (that includes images of the image pool first library) and the visualization simulation (with the missing image gif issue). Any idea of what i forgotten in the process? If you need any detail of the library or of the project or you need the library file, ask me, thank on advance
Last updated: 2024-08-19

Post by julianramirez on ModbusFB write update CODESYS Forge talk (Post)
Hello everyone, I am testing the ModbusFB library tcp server and so far I am able to create holding registers successfully, however, I am trying to identify after each write which registers got updated (i.e. function code, write value). I can even see the var udiNumWriteRequests, which increases with every write. I noticed that there is logging with the LogStatusInfo method. After I call it I am able to read in the console stuff that I want. Nevertheless, this is only available at the logs and is not easy to decode because it consists on several messages, I would like to know if there is a way for me to retrieve this information from the function itself with pointers or if there is any way to copy the logs messages (assuming that I can filter them with the LoggingOptions to only show what I need) inside the runtime code and not in the console. Thanks for your help :)
Last updated: 2024-09-16

Post by alexgooi on Codesys OPC DA server requires more then 2 GB of ram CODESYS Forge talk (Post)
Dear Forum, We are currently running into a problem that the CODESYS OPC DA server is running out of RAM (larger than 2 GB). We have a setup of 10 Codesys controllers which features around 300.000 discoverable tags per controller. We are only interested in 10 percent of the tags to be communicated to the OPC-server, this is due to the fact the program consists of arrays of objects which on their part implements arrays of objects, simply reducing the number of discoverable tags is not an option The OPC-DA server loads all the discoverable tags, is it possible to: 1 let the OPC-DA server only load the tags that are requested by the SCADA/MES system. 2 let the OPC-DA server claim more memory. 3 run 2 OPC-DA servers in parallel? Thank you in advance
Last updated: 2024-01-25

Post by paulorb on STRUCT AT %MW1000 CODESYS Forge talk (Post)
Hi I am trying to use STRUCT to parse commands from Modbus/TCP, Modbus client will fill the bytes related to a specific command (type, parameters), then PLC (Codesys) will access the command parameters. A STRUCT will simplify a lot the process of parsing the data, so I don't need to parse byte per byte, address will be mapped to a struct and I can use it for parsing the data. From what I understood, the compiler does not allow me to specify the location of the struct for a %MW register. VAR_COMMAND AT %MW1002: structGenericModbusCommand; This will throw: Bad declaration, use '%ML' for 'structGenericModbusCommand' variable But If I change it to %ML, when you go online you see that it is actually allocating the struct in another memory address. When we go online, on GVL we can see: VAR_COMMAND. structGenericModbusCommand %ML1002 commandType COMMANDTYPE %MB8016 ... %MB8020 I am not specifying a pointer or a reference it is a struct type, why is it mapping to a %MW location (random one). How can I control where it is mapping to? I need a consistent way to map STRUCT to specific modbus address. Is it possible? Thanks, Paulo Note I am using a Codesys OEM: Schneider Machine Expert Logic Builder (M241)
Last updated: 2024-08-13

Post by tk096 on Some 'pathetic' errors in SoftMotion program CODESYS Forge talk (Post)
Meanwhile, I would like to understand why the motion FB instances must still be called even after the Execute is set to FALSE, especially in view of the fact that the next instruction is programmed to abort the previous one, with BufferMode set to 'Aborting'. All these unnecessary FB calls are an unnecessary overhead on the CPU anyway. Is there any precise rule about when to cease calling the various instances? (It should precisely be the 'done' status that says this one has finished its work). In general: - Motion function blocks have to be called until they report 'Done', 'Error', 'CommandAborted' or a subsequent motion FB with BufferMode=Aborting is started in the current cycle. - Setting the Execute input to FALSE will not abort any ongoing motion of the motion function block. For example, one case that is often problematic is the execution of the Axis Halt instruction. When, after a MoveAbosulte instruction this returns the event as 'done' and indeed the axis is in standstill, the state machine first sets the move instruction to FALSE, and the next cycle sets the Halt request to TRUE. Some of the time everything works out fine. Occasionally, however, in this exchange, the axis goes into fault, also losing the OPERATIONAL state. I think the error SMC_FB_WASNT_CALLED_DURING_MOTION is only a follow-up (and misleading) error that results from the axis not being in operational state anymore (bus problems). Is there an error 'regulator or start not set' in the device log before the error 'motion generating FB wasn't called for at least one cycle'? Which error does the respective function block (Halt.ErrorId) report?
Last updated: 2024-07-22

Post by gallusrrr on usb2can in Codeysy 3.5 Can Gateway CODESYS Forge talk (Post)
Hallo und guten Morgen, Ich danke für die Rückmeldung. ich habe das oben geschriebene durchgeführt und auch festgestellt das mit die Commandos für die Can befehle noch fehlen. (Google angeschmissen und geschaut auch gefunden) sudo apt-get install can-utils (damit auch jemanden anders der Post hilft) Anschließend habe ich das CAN System komplett aufgebaut so das ich mit einen anderen CAN Adapter schauen konnte ob die Nachricht auch ankommt. die Nachricht kommt an :) danach habe ich follgende Ausgabe: pi@Codesys:~ $ sudo ip -s -d link show can0 3: can0: <noarp,up,lower_up,echo> mtu 16 qdisc pfifo_fast state UP mode DEFAULT group default qlen 10 link/can promiscuity 0 allmulti 0 minmtu 0 maxmtu 0 can state ERROR-ACTIVE restart-ms 0 bitrate 250000 sample-point 0.875 tq 250 prop-seg 6 phase-seg1 7 phase-seg2 2 sjw 1 brp 12 gs_usb: tseg1 1..16 tseg2 1..8 sjw 1..4 brp 1..1024 brp_inc 1 clock 48000000 re-started bus-errors arbit-lost error-warn error-pass bus-off 0 0 0 0 0 0 numtxqueues 1 numrxqueues 1 gso_max_size 65536 gso_max_segs 65535 tso_max_size 65536 tso_max_segs 65535 gro_max_size 65536 parentbus usb parentdev 1-1.4:1.0 RX: bytes packets errors dropped missed mcast 3549 819 0 0 0 0 TX: bytes packets errors dropped carrier collsns 32 4 0 0 0 0</noarp,up,lower_up,echo> (Sorry habe kein Speicherplatz im Web um Bilder anzuzeigen..) man kan sehen das die Nachricht abgeht und auch 32 Byte Empfangen worden sind. Die nachricht ist auch am anderen CAN Adapter sichtbar gewesen. Wie bekomem ich den einrichteten Adapter in Codesys rein? das ich den Befehl sudo ip link set can0 up type can bitrate 500000 das ich die Einrichtungs des Can Adapters noch in die Rasperry Start rutine nehmen muss ist mir klar. Ich bedanke mich .
Last updated: 2024-01-18

Post by umdee on Error when monitoring LAD programs CODESYS Forge talk (Post)
I get the following error when monitoring my program (see attached screenshots): "Unhandled exception has occured in your application. If you click Continue, the application will ignore this error and attempt to continue. If you click Quit, the application will close immediately. Value cannot be null. Parameter name: source. And the details say: See the end of this message for details on invoking just-in-time (JIT) debugging instead of this dialog box. ** Exception Text ** System.ArgumentNullException: Value cannot be null. Parameter name: source at System.Linq.Enumerable.Any[TSource] (IEnumerable1 source, Func2 predicate) at _3S.CoDeSys.NWLEditor.NWLTextCell.OnPaintCellLayer(PaintEventArgs e) at _3S.CoDeSys.Controls.Controls.GfxEdControl.PaintCellCellLayer(PaintEventArgs e, GfxCell cell) at _3S.CoDeSys.Controls.Controls.GfxEdControl.PaintCellCellLayer(PaintEventArgs e, GfxCell cell) at _3S.CoDeSys.Controls.Controls.GfxEdControl.PaintCellCellLayer(PaintEventArgs e, GfxCell cell) at _3S.CoDeSys.Controls.Controls.GfxEdControl.OnPaint(PaintEventArgs e) at System.Windows.Forms.Control.PaintWithErrorHandling(PaintEventArgs e, Int16 layer) at System.Windows.Forms.Control.WmPaint(Message& m) at System.Windows.Forms.Control.WndProc(Message& m) at System.Windows.Forms.UserControl.WndProc(Message& m) at _3S.CoDeSys.Controls.Controls.GfxEdControl.WndProc(Message& m) at System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam) ** Loaded Assemblies ** (3000 lines of assemblies) ** JIT Debugging ** To enable just-in-time (JIT) debugging, the .config file for this application or computer (machine.config) must have the jitDebugging value set in the system.windows.forms section. The application must also be compiled with debugging enabled. For example: <configuration> <system.windows.forms jitdebugging="true"> </system.windows.forms></configuration> When JIT debugging is enabled, any unhandled exception will be sent to the JIT debugger registered on the computer rather than be handled by this dialog box The windows show red X's where the networks should be. Any advice on how to fix this? Additional Information PLC used: Wago 750-8212, Firmware FW26 Startup profile: CODESYS V3.5 SP19 Patch 5 OS version: Microsoft Windows NT 10.0.22631.0 .NET version: 4.0.30319.42000 Full Version info attached as .txt
Last updated: 2024-03-17

Post by manuknecht on Maximum dynamic limits of MC_MoveLinearAbsolute and MC_MoveLinearRelative CODESYS Forge talk (Post)
Hello all I use an axis group with two linear axes in a kinematic system. Using MC_MoveLinearAbsolute and MC_MoveLinearRelative, I am trying to realise dynamic movements (set velocity: 1 m/s, set acceleration: 30 m/s^2) with the highest possible jerk, as I want to compare this with a movement with a trapezoidal velocity profile. However, my measurements show that the axes accelerate with a maximum jerk of approx. 800 m/s^3, even if the value in the function block was set to 10,000 m/s^3. I have already increased the dynamic limits of the two axes accordingly (Velocity: 5000 u/s, Acc-/Deceleration: 250'000 u/s^2, Jerk: 100'000'000 u/s^3, where 1 u = 1 mm), but this had no effect. I have checked the input parameters of the function blocks and the VelFactor, AccFactor and JerkFactor factors are all set to the maximum (value 1). Reducing the cycle time has resulted in a higher jerk, but as we are already working with a cycle time of 1 ms, there is nothing more that can be done here. The axes themselves are still a long way from drawing the maximum current, which is why I assume that this should not be a problem either. Are there other factors or parameters that influence the dynamic limits and therefore allow faster movements? The PLC I am using is a Raspberry Pi 4 and Codesys V3.5 SP20 with all libraries up to date. Thanks in advance Manuel
Last updated: 2024-05-08

Post by hwillems on Ranges, Lambdas, on Fixed arrays of structs CODESYS Forge talk (Post)
I do datastructures and algorithms in Codesys. For example a Struct of Person with thing's like IdNumber, Name, Age etc. as example. Now i do all kind of calculations, filters. So i have this pretty big Fixed Array with Structs. On this struct i want to do simple stuff you can do easily in C++/Python/Rust etc. For example i want to do this: AvererageAge := Average(Peoples.Age); Then it will return the average of all members ages. Or Sort struct on age etc. Or sort on alphabetical Name. Or use Lambda functions to filter/mutate out things like, filter out everybody above 18 years old. Or remove people who it's name start with "A". Currently i have to write my own custom function for example sorting on Age. And make a super specific function based on that particulare datastructure. Here an Example: (*Before calling this FIlter method, set the mNodeFilterSwitch to the desired filter.*) CASE mNodeFilterSelect OF (********************************[ Status Filters ]***********************************) NodeID: FOR x := ACS_OUT_BEGIN TO ACS_OUT_END BY 1 DO FOR y := ACS_IN_BEGIN TO ACS_IN_END BY 1 DO IF marrNode[y].Status.oiNodeID > marrNode[y + 1].Status.oiNodeID THEN mNodeTemp := marrNode[y + 1]; marrNode[y + 1] := marrNode[y]; marrNode[y] := mNodeTemp; END_IF; END_FOR; END_FOR; Started: FOR x := DES_OUT_BEGIN TO DES_OUT_END BY -1 DO FOR y := DES_IN_BEGIN TO DES_IN_END BY -1 DO IF marrNode[y].Status.oxStarted > marrNode[y - 1].Status.oxStarted THEN mNodeTemp := marrNode[y - 1]; marrNode[y - 1] := marrNode[y]; marrNode[y] := mNodeTemp; END_IF; END_FOR; END_FOR; Starting: FOR x := DES_OUT_BEGIN TO DES_OUT_END BY -1 DO FOR y := DES_IN_BEGIN TO DES_IN_END BY -1 DO IF marrNode[y].Status.oxStarting > marrNode[y - 1].Status.oxStarting THEN mNodeTemp := marrNode[y - 1]; marrNode[y - 1] := marrNode[y]; marrNode[y] := mNodeTemp; END_IF; END_FOR; END_FOR; END_CASE; I have like 30+ of these in the enum. Not really DRY code right? These are custom made bubble sort filters in a function. You pass in the Datastructure, and say what function you want. (This is an enum collection of sorting functions) And then the Array with Nodes of Structs gets ordered. Why can't we have Iterators and Lambda's and build in standard functions like regular languages? Also i use bubble sort because it's the easiest to implement because i can't get this to code DRY. Problem with ST (Even the new one with classes) that it's very limited for programming datastructures and algorithms. Yes you still not want dynamic memory and you need to choose the correct algorithm so you know the most extreme edge cases regarding the time it takes to execute the algorithms.(Real-time execution) How are other people dealing with this? Here for example saw some software using an adjusted ST language and having FOR EACH possibility: https://www.fernhillsoftware.com/help/iec-61131/structured-text/st-for-each.html You can then build your own custom Iterator functions. I wish the IEC 61131-3 standard would be more expressive and having more standard modern features, but still keep close to the fact of no dynamics memory and real-time systems.
Last updated: 2023-08-31

Post by bbm1995 on Camera RTSP Feed CODESYS Forge talk (Post)
Hi dgrard, I had the same issue for a long time, but on a WAGO webvisu. Now I'm glad that I can share my solution. I don't know if you are trying to use the webvisu or the target visu, but this works on webvisu: Get "go2rtc" and set it up according to the documentation. I'm running the Windows binary. Here's my example of the go2rtc.yaml config file (contains working example streams): api: listen: ":1984" # default ":1984", HTTP API port ("" - disabled) origin: "*" # default "", allow CORS requests (only * supported) static_dir: "www" # default "", folder for static files (custom web interface) tls_listen: ":443" # default "", enable HTTPS server tls_cert: "./SSL/fullchain.pem" tls_key: "./SSL/privatekey.pem" streams: # Streams with multiple links will fall back on the next link. ABUS TVIP48511: - rtsp://<username>:<password>@<hostname>:<port>/ch1/main - rtsp://<username>:<password>@<hostname>:<port>/ch1/sub # Diagnostic connections Kirchhoff Institute for Physics - Germany: http://pendelcam.kip.uni-heidelberg.de/mjpg/video.mjpg Blanton Bottling, Kentucky - USA: http://camera.buffalotrace.com/mjpg/video.mjpg Tokyo - Japan: http://61.211.241.239/nphMotionJpeg?Resolution=320x240&Quality=Standard Tampere Hacklab - Finland: http://tamperehacklab.tunk.org:38001/nphMotionJpeg?Resolution=640x480&Quality=Clarity Soltorget Pajala - Sweden: http://195.196.36.242/mjpg/video.mjpg Kaiskuru Skistadion - Norway: http://77.222.181.11:8080/mjpg/video.mjpg webrtc: listen: ":8555" #ice_servers: # - urls: [ "stun:localhost:3478" ] # username: "" # credential: "" Access the webinterface of go2rtc and get the link of your stream. Use the link as for your browser frame in the visualization. Depending on your device, you need to be able to access the file /etc/lighttpd/lighttpd.conf or /etc/lighttpd/webvisu.conf and change the contents similar to this one, otherwise you'll get CORS and CSP errors in the browser and you won't be able to view the stream on the webvisu: # Webvisu specific settings $SERVER["socket"] =~ port_webvisu_used_any { url.redirect += ( "^/webvisu/?$" => "/webvisu/webvisu.htm" ) $HTTP["url"] =~ "^/webvisu/?" { var.response_header_policy_webvisu = ( # CSP for WebVisu, allowing inline sources. "Content-Security-Policy" => "default-src 'self' 'unsafe-inline'; media-src *; frame-src *", # CORS for WebVisu, allowing any origin to access. "Access-Control-Allow-Origin" => "*", # Tell older browsers that this page can only be displayed if all ancestor # frames are same origin to the page itself. "X-Frame-Options" => "SAMEORIGIN" ) # Response header policy for WebVisu setenv.set-response-header = var.response_header_policy_webvisu setenv.set-response-header += var.response_header_policy_common }
Last updated: 2023-11-14

Post by george32 on CSV file and string manipulation. CODESYS Forge talk (Post)
Dear folks, I think I have a rather simple question but I could not find the right answer to my question: I have made with Excel a CSV file where I would like to have some general data regarding my program variables. I have made an program what let me read the file. The string I am currently get is at follows: 'IP_Adres;192.168.45.12$R$NPort_number;2000$R$NCycle_time;43$R$NStart_Standard_IO;20$R$N' Now I want to split the string in multiple part, which I later would connect to the right variable. By Google and experimenting I have reached to the following code for the first part of the splitting proces: // Splitting the BOM of the string: Received_string := FileReadString; IF LEFT(STR:=New_string,3)= '' THEN Received_string_without_BOM :=RIGHT(STR:= Received_string,SIZE:= (LEN(STR:= Received_string))-3); END_IF //Splitting the remaining string in part for later declaration. WHILE index = 0 DO index_split_part := FIND(STR1:= Received_string_without_BOM,STR2:= '$R$N'); Part_of_String[index]:=LEFT(STR:=Received_string_without_BOM, SIZE:= index_split_part); index := index + 1; END_WHILE However in the splitting proces I could not understand what is really happening. I understand that the Find() function returns the first value the $R$N in the Received_string_without_BOM. This would mean that the index_split_part := 23 I|P| _ |A |d|r|e|s|;|1_|9 |2 |. |1 |6 |8 |. |4 |5 |. |1 |2 |$ |R |$ |N |P | 1|2| 3 |4 |5|6|7|0|9|10|11|12|13|14|15|16|17|18|19|20|21|22|23|24|25|26|27| So the next part is to read the first 23 characters of the Received_string_without_BOM with the LEFT() function. I expected that the outcome the following was: 'IP_Adres;192.168.45.12$'. However the outcome is: 'IP_Adres;192.168.45.12$R'. I do not understand where the R after the $ sign comes from, because its place is 24 so it would not be added to the part_of the_string[index]. If I hard coded value 24 for the size it gives me the following return: 'IP_Adres;192.168.45.12$R$N'. I would expect everything till the R but the code adds the $N also to the string. I hope someone could explain to my what I am seeing wrong in my point of view? With kind regards, George
Last updated: 2024-09-27

Post by jackbrady on Function Blocks and arrays of function blocks CODESYS Forge talk (Post)
Hello, I am new to Codesys and PLC programming in general (please go easy ha!) I'm not looking for code to be written for me just some help and pointing in the right direction. I am writing some code to send commands to a relay based on input values (to put it simply). Quite basic stuff. I have wrote a function block that takes a global variable (Open_command:BOOL) and outputs to another global variable (Opened : BOOL). The function block is simulating a device so I'll eventually get the globals from that. I now need to create multiple versions of this function block/ device (lets say 100) but I need each iteration of that function block to reference it's own relevant global variable. I think that the best way of doing this would be to use arrays, although I could be wrong. I am aware that for up to 100 instances I could very well manually assign everything but that seems rather time consuming and I want a fancier way of doing it. Here is a very basic example of what I am looking to do, please note I have not written this in proper code it's just to show what I mean. Global Variables V[0-100] int Open_command [0-100] Bool Opened [0-100] Bool Function Block var input x : BOOL Var output y : BOOL if x then y = TRUE ELSE y = FALSE The input to my function block will be Open_command, output will be Opened Example code. If V[x] > 10 then Open_command [x] = TRUE ELSE Open_command [x] = FALSE (So when V1 goes above 10 I need Open_command1 = TRUE therefore initiating FB1 output. V2 > 10, open_command2 = True > FB2 output V3 > 10, open_command3 = True > FB3 output ... ... ) What I can't seem to figure out is how to tie all this together, I have read through the codesys documentation and if anything it has confused me more! ha. Apologies for the poorly written post but hopefully you understand what I am trying to get at. Thanks, Jack
Last updated: 2024-02-14

Post by pppn on Issue with Forward Open Connections in Ethernet/IP Protocol Stack in Codesys CODESYS Forge talk (Post)
Hello, I am facing an issue with my Ethernet-based project in Codesys. My product was functioning well until I modified the protocol stack and uploaded it to my device. Here are the details of my problem: Project Setup: I am working on an Ethernet-based project to test my product. The project was running without issues before modifying the protocol stack. Issue: After modifying the protocol stack and uploading it to my device, I am encountering an error in Codesys related to the forward open connections. Error status: connection failure, extended: connection in use or duplicate forward open. According to the Ethernet/IP protocol in codesys, there are three forward open connections that need to be established. The first two connections are opening without any issues. The third connection, which is an input-only connection, is causing problems. The error message indicates that the connection is already open. Debugging Attempts: I have extensively debugged the protocol stack and found no issues. The product works well when tested with EIP tools but not with Codesys. Exclusive owner connections are working correctly, and only the input-only connection is problematic. Wireshark Traces: Wireshark traces show that the third connection attempts to open but reports that it is already open. Steps to Reproduce: Modify the protocol stack and upload it to the device. Attempt to establish three forward open connections in Codesys. Observe the error on the third connection (input-only). Request: I would appreciate any suggestions or guidance on how to resolve this issue. If there are specific settings or configurations in Codesys that I need to check, please let me know. Additionally, if there are known issues or workarounds related to this problem, I would be grateful for the information. Attachments: Wireshark traces showing the connection attempts and errors Screenshots of the error messages in Codesys codesys version: CODESYS V3.5 SP16 Patch 3 + 64 bit
Last updated: 2024-06-25

Post by pppn on Issue with Forward Open Connections in Ethernet/IP Protocol Stack in Codesys CODESYS Forge talk (Post)
Hello, I am facing an issue with my Ethernet-based project in Codesys. My product was functioning well until I modified the protocol stack and uploaded it to my device. Here are the details of my problem: Project Setup: I am working on an Ethernet-based project to test my product. The project was running without issues before modifying the protocol stack. Issue: After modifying the protocol stack and uploading it to my device, I am encountering an error in Codesys related to the forward open connections. Error status: connection failure, extended: connection in use or duplicate forward open. According to the Ethernet/IP protocol, there are three forward open connections that need to be established. The first two connections are opening without any issues. The third connection, which is an input-only connection, is causing problems. The error message indicates that the connection is already open. Debugging Attempts: I have extensively debugged the protocol stack and found no issues. The product works well when tested with EIP tools but not with Codesys. Exclusive owner connections are working correctly, and only the input-only connection is problematic. Wireshark Traces: Wireshark traces show that the third connection attempts to open but reports that it is already open. Steps to Reproduce: Modify the protocol stack and upload it to the device. Attempt to establish three forward open connections in Codesys. Observe the error on the third connection (input-only). Request: I would appreciate any suggestions or guidance on how to resolve this issue. If there are specific settings or configurations in Codesys that I need to check, please let me know. Additionally, if there are known issues or workarounds related to this problem, I would be grateful for the information. Attachments: Wireshark traces showing the connection attempts and errors Screenshots of the error messages in Codesys codesys version: CODESYS V3.5 SP16 Patch 3 + 64 bit
Last updated: 2024-06-25

Post by gilbert-mh on CAA net base TCP client cause PLC to crash - Kernel message : N0HZ_local_softirq_pending 80 CODESYS Forge talk (Post)
Hello all, I have been trying to implement a TCP client on a Festo PLC (CPX-E-CEC-M1) and it looks like it works well except that after some time (greatly varies between a few hours to more than 100h) my PLC crash. When I look into the log file the only thing I see is that before the crash happens a few kernel warnings : N0HZ_local_softirq_pending 80 and then the crash. I've looked into this warning and from what I could find on the net it seems that this is warning is triggered when the ethernet link is down. I've tried to correct this bug for quite some time and what I know is that : - The crash is caused by my TCP client, when I remove it from my code I see no crash - The crash happens more quickly the more the TCP client is used. - The time before the crash is not directly proportional to the number of communications or their size. But it looks like it is just more likely to happen if the client connect to the server at a higher frequency. - The precedent observation makes it seem unlikely that the crash is caused by some memory overflow because then the crash speed would be more proportional to the amount of data exchanged. SO from these observations, I believe that the crash could be caused by the PLC trying to connect to a server while there is some kind of issue with the ethernet link resulting in the PLC getting stuck in some indefinite state and making it crash. This still seems a bit unlikely to me because if the ethernet is down it simply shouldn't be able to contact the server and the communication would just fail which doesn't cause my PLC to crash. Has anyone encountered the same kind of problem (with the same kernel message) ? I am pretty sure the warning is not the direct cause of the crash but just an indicator that something is wrong with my PLC. Thanks in advance
Last updated: 2024-01-12

Post by paulg on RasPi CAA Serial example - unexpected behavior during debug CODESYS Forge talk (Post)
I've trimmed down the CAA Serial Codesys example to only listen on one port but, when stepping through the Case structure in debug mode, it jumps out of the structure during a specific point in every scan (I'll point it out below after describing the setup and listing the code). I'm using a Pi 4 Model B, and I have an Arduino Nano Every plugged in via USB which is streaming the following serial message at 1 Hz: Time since opening connection: 1 s Time since opening connection: 2 s ...and so on. The Pi shows the Nano at /dev/ttyACM0 so I edited CODESYSControl_User.cfg to read: Linux.Devicefile=/dev/ttyACM The code in my PLC_PRG is (ignore some of the comments, I hadn't deleted them out from the original example): PROGRAM PLC_PRG VAR xStartTest : BOOL:= TRUE; iState : INT; xTestDone : BOOL;(* True, when the test was done succesfully *) (* Settings to communicate with the COM Port *) aCom1Params : ARRAY [1..7] OF COM.PARAMETER; como1 : COM.Open; comc1 : COM.Close; comw1 : COM.Write; comr1 : COM.Read; //sWrite : STRING := 'Test String!'; sRead : STRING(25); szRead : CAA.SIZE; xCom1OpenError : BOOL; xCom1CloseError : BOOL; xCom1WriteError : BOOL; xCom1ReadError : BOOL; END_VAR //This example shows the communication of two COM Ports with each other. //The first one writes a string of characters, which is read by the second one. //After successful execution, the two COM Ports are closed and the test is done. IF xStartTest THEN CASE iState OF 0: //The parameters are set for the COM Port aCom1Params[1].udiParameterId := COM.CAA_Parameter_Constants.udiPort; aCom1Params[1].udiValue := 1; // the correct Port should be adapted aCom1Params[2].udiParameterId := COM.CAA_Parameter_Constants.udiBaudrate; aCom1Params[2].udiValue := 115200; aCom1Params[3].udiParameterId := COM.CAA_Parameter_Constants.udiParity; aCom1Params[3].udiValue := INT_TO_UDINT(COM.PARITY.NONE); aCom1Params[4].udiParameterId := COM.CAA_Parameter_Constants.udiStopBits; aCom1Params[4].udiValue := INT_TO_UDINT(COM.STOPBIT.ONESTOPBIT); aCom1Params[5].udiParameterId := COM.CAA_Parameter_Constants.udiTimeout; aCom1Params[5].udiValue := 0; aCom1Params[6].udiParameterId := COM.CAA_Parameter_Constants.udiByteSize; aCom1Params[6].udiValue := 8; aCom1Params[7].udiParameterId := COM.CAA_Parameter_Constants.udiBinary; aCom1Params[7].udiValue := 0; //The first Port is opened with the given parameters como1(xExecute := TRUE, usiListLength:=SIZEOF(aCom1Params)/SIZEOF(COM.PARAMETER),pParameterList:= ADR(aCom1Params)); IF como1.xError THEN xCom1OpenError := TRUE; iState := 1000; END_IF //After a successful opening, the next state is reached IF como1.xDone THEN iState := 15; END_IF 15: // the reading process is started comr1(xExecute := TRUE,hCom:= como1.hCom, pBuffer:= ADR(sRead), szBuffer:= SIZEOF(sRead)); IF comr1.xError THEN xCom1ReadError := TRUE; END_IF //After completion the size of the written bytes are saved IF comr1.xDone OR comr1.xError THEN szRead := comr1.szSize; iState := 20; END_IF 20: // If everything was successful the ports are closed and the handles are released comc1(xExecute := TRUE,hCom:= como1.hCom); IF comc1.xError THEN xCom1CloseError := TRUE; END_IF IF comc1.xDone OR comc1.xError THEN iState := 25; END_IF 25: // The first port is closed and the used handle released xTestDone := TRUE; xStartTest := FALSE; iState := 0; como1(xExecute := FALSE); comw1(xExecute := FALSE); comc1(xExecute := FALSE); ELSE iState := 0; END_CASE END_IF I realize as I write this that the .udiPort should be 0 and not 1, but that shouldn't be causing the issue I'm seeing. I'm forcing xStartTest:=TRUE every scan so that I can step into each line and observe what's happening. What I see is that the port parameters are set and the port is opened with no errors, but the code jumps out of the case structure to the last line every time it reaches (and I step into) the iState:=15 line (at the end of the iState:=0 block). So every scan cycle it goes through the block for iState=0 and jumps out at the same spot. I'm a little new to PLC programming so I may be misunderstanding the flow, but shouldn't this case structure keep moving down in the same scan? If it only handles one case per scan, why doesn't the value of iState persist? Thanks! Update: I restarted the Codesys control today and I was then able to see an error for como1.eError of "WRONG_PARAMETER". I tried doing some digging and another post made me think I should add another line to CODESYSControl_User.cfg, so I now have: [SysCom] Linux.Devicefile=/dev/ttyACM portnum := COM.SysCom.SYS_COMPORT1 So now when I set .udiPort to 1, I get "NO_ERROR" but I also don't read anything from the port (i.e. szRead = 0 always). If I try setting the port to 0 (which I'm confused about, because I added a COMPORT1 line but the device shows on the Pi as ACM0), I get the "WRONG_PARAMETER" error again. Is there an easier way to troubleshoot the Pi and view what ports the Codesys runtime is actually able to see while the Pi is running?
Last updated: 2024-06-06

Post by ihatemaryfisher on Sorting array of any-sized structure CODESYS Forge talk (Post)
In my machine's operation, I need to display multiples tables containing arrays of structured variables. The arrays change during operation, and my supervisor has advised me to write a new bubble-sort for each array. I think I can make a function to sort an array of any data type. This was my own project, and I'm a relatively new coder. I want to know the weaknesses in my approach, and a better method, if one exists. As far as I can test, the function accepts an array of a structured variable of any size, and sort it by any VAR in that structure. But it relies heavily on pointers, which I've heard are bad practice? Function call: // SORT BY BYTE-SIZED VAR IF xDoIt[6] THEN FUNBubbleSortSansBuffer( IN_pbySourcePointer := ADR(astArray[1]), // address of first byte in first element of array IN_pbyComparePointer:= ADR(astArray[1].byCompByte), // points to first byte of the comparing variable (variable you sort by) IN_uiStructureSize := SIZEOF(TYPE_STRUCTURE), // size, in bytes, of the structured variable IN_uiCompareSize := SIZEOF(astArray[1].byCompByte), // size, in bytes, of the comparing variable (variable you sort by) diArrayElements := UPPER_BOUND(astArray,1), // number of elements in array IN_xSmallToLarge := xSortOrder // whether to sort by small2large or large2small ); END_IF Function: FUNCTION FUNBubbleSortSansBuffer : BOOL VAR_INPUT IN_pbySourcePointer : POINTER TO BYTE; // points to beginning of array (first byte of first element) IN_pbyComparePointer: POINTER TO BYTE; // points to first byte of the comparing variable (variable you sort by) IN_uiStructureSize : UINT; // size, in bytes, of the structured variable IN_uiCompareSize : UINT; // size, in bytes, of the comparing variable (variable you sort by) diArrayElements : DINT; // number of elements in array IN_xSmallToLarge : BOOL; // whether to sort by small2large or large2small END_VAR VAR j : DINT; // repeat iteration over array until array ends i : DINT; // iterarte over array, swapping when necesary k : DINT; // iterator from 1 to size of structure (stepping 'through' a single element in array) dwSize : DWORD; // internal var for use in MEMUtils.MemCpy(<size>) // FOR SORTING BY BYTE VAR pbySourcePointer : POINTER TO BYTE; pbySourcePointer2 : POINTER TO BYTE; pbyComparePointer : POINTER TO BYTE; pbyComparePointer2 : POINTER TO BYTE; pbyPointerToBuffer : POINTER TO BYTE; // pointer to single byte buffer byBufferByte : BYTE; // single byte buffer END_VAR dwSize := UINT_TO_DWORD(IN_uiStructureSize); // get structure size (number of bytes) pbyPointerToBuffer := ADR(byBufferByte); // assign pointer to address of buffer byte (because MEMUtils.MemCpy requires a pointer input) CASE IN_uiCompareSize OF // depending on the size of the VAR to sort by (current functionality for BYTE and WORD/INT 1: // BYTE (8 BIT) FOR j := 1 TO diArrayElements DO // for number of elements in array FOR i := 1 TO (diArrayElements-1) DO // same thing, but row[i+1] row is included in swap logic pbySourcePointer := IN_pbySourcePointer + dwSize*(i-1); // point at #1 byte in array element[i] pbySourcePointer2 := pbySourcePointer + dwSize; // point at #1 byte in array element[i+1] // NOTE: because of memory locations, each array element is offset from one another by a number of bytes equal to the size of the structure // We can "walk" from array[i] to array[i+1] via steps equal to the size of the structure // e.g., ADR(array[i+1]) == ADR(array[i]) + SIZEOF([array datatype]) pbyComparePointer := IN_pbyComparePointer + dwSize*(i-1); // point to sorting variable in array element[i] pbyComparePointer2 := pbyComparePointer + dwSize; // point to sorting variable in array element[i+1] // using sort order (small -> large/large -> small) IF SEL(IN_xSmallToLarge, (pbyComparePointer2^ > pbyComparePointer^),(pbyComparePointer2^ < pbyComparePointer^)) THEN // This is where it gets tricky. We've identified pointers for the starting bytes of aArray[i] and aArray[i+1] // and we know the size of aArray[i]. We are going to swap individual bytes, one at a time, from aArray[i] and aArray[i+1] // this allows us to use only a single byte var as a buffer or temporary data storage // e.g., consider a structure consisting of a word, a byte, and a string. it is stored like this // |------WORD-------| |--BYTE-| |STRING------...| // astArray[1] == 1000 0100 0010 0001 1100 0011 1010 1010.... etc // astArray[2] == 0001 0010 0100 1000 0011 1100 0101 0101.... etc // performing a single swap (copy into a buffer, etc.) of the first byte of each array element creates this // astArray[1] == 0001 0100 0010 0001 1100 0011 1010 1010.... etc // astArray[2] == 1000 0010 0100 1000 0011 1100 0101 0101.... etc // incrementing the pointer adresses for the swap by 1 and swapping again swaps the next byte in each array element // astArray[1] == 0001 0010 0010 0001 1100 0011 1010 1010.... etc // astArray[2] == 1000 0100 0100 1000 0011 1100 0101 0101.... etc // continuing this from k to SIZEOF(TYPE_STRUCTURE) results in a toally swapped row FOR k := 1 TO IN_uiStructureSize DO // copy single byte[k] of array element 1 to buffer MEMUtils.MemCpy(pbyDest := (pbyPointerToBuffer), pbySrc := (pbySourcePointer+k-1), dwSize := 1); // copy single byte[k] of array element 2 to 1 MEMUtils.MemCpy(pbyDest := pbySourcePointer+k-1, pbySrc := (pbySourcePointer2+k-1), dwSize := 1); // copy buffer to byte[k] array element 2 MEMUtils.MemCpy(pbyDest := (pbySourcePointer2+k-1), pbySrc := pbyPointerToBuffer, dwSize := 1); END_FOR END_IF END_FOR END_FOR
Last updated: 2023-08-17