Post by rikher on Error: Too few outputs exixts for the box 'MemCopy' (minimum is 1).
CODESYS Forge
talk
(Post)
I am using MemCopy Function for this example: https://www.youtube.com/watch?v=DeTCT5Vyn28&t=482s It is from library WagoSysPlainMem. I want to use this for an MQTT example. However, Codesys is complaining the block does not have outputs. How to fix this?
Last updated: 2024-06-19
Post by kuegerls on SysProcessExecuteCommand2 and CANopen Device
CODESYS Forge
talk
(Post)
I have now conducted some tests. The problem occurs when the Python script establishes an OPCUA connection, even if I only establish the connection without reading or writing any data. Is there another way to exchange data between Python and CODESYS without having to put in a lot of effort?
Last updated: 2024-06-24
Post by mucleus on What is the solution for "Application stopped on recovery switch request"?
CODESYS Forge
talk
(Post)
Hi, everyone. I am using CODESYS RTE and Profinet I/O or EtherCAT I/O. Occasionally (once every 1-2 months) the attached image occurs and the program stops. I want to know why this phenomenon occurs and how to solve it. I attached log. Please help me. Thanks.
Last updated: 2024-07-05
Post by stiller on OPC UA RPI 4.8.0.0 Status Code / "out of range"
CODESYS Forge
talk
(Post)
Hello, I have an OPC-UA server with an information model. For many values, there is a defined range (e.g., 0 to 100). If a client enters a value outside this range (e.g., 120), the StatusCode should change to Bad. How can I accomplish this? Any help is appreciated! Thank you in advance. Best regards, Christian Stiller
Last updated: 2024-07-10
Post by maxkemmeren on PFC200 (750-8214) high linux load average, but seems random. Possibly EtherCAT related.
CODESYS Forge
talk
(Post)
Have you received any feedback or found any solutions to the load problem. We are running into similar issues, even without codesys running the load avarage is above 1 meaning that it is to busy already without plc code running. Hope you might have some more insight.
Last updated: 2024-07-11
Post by tk096 on Some 'pathetic' errors in SoftMotion program
CODESYS Forge
talk
(Post)
Hi, I suppose that you are referring to the error code "SMC_FB_WASNT_CALLED_DURING_MOTION"? Starting of Softmotion version 4.15.0.0 the instance path of the function block that has not been called is logged into the device log. This might help you to identify why it has not been called.
Last updated: 2024-07-18
Post by mubeta on Some 'pathetic' errors in SoftMotion program
CODESYS Forge
talk
(Post)
Thank you for your interest. Your answers are in line with what I knew, so at least it comforts me that I did not misinterpret the situation. However, I don't have an exact match as, for this project over the past few days I have: 1) I have gone back to leaving the various FBs of the motion always called, all of them, and in the state machine I use a boolean to activate the various useful Execute. (But in the future I want to go back and try the programming technique with which I wanted to develop this project); 2) For the occasional error: SMC_FB_WASNT_CALLED_DURING_MOTION perhaps it was due to the fact that I had set the Ethercat bus synchronism only at the CAN master level, but not at the level of individual drives. I have now also activated it for the individual drives and it does indeed seem to have been resolved, but having also adopted the programming technique mentioned in point 1), I cannot say whether this was the solution to the problem, or instead the previous point. Is there an error ‘regulator or start not set’ in the device log before the error ‘motion generating FB wasn't called for at least one cycle’? I can't answer that right now. By now the machine is running and I am no longer there, at this one. Also, I seem to remember that the 'fbeFBerror' drive structure (5-element array), does not cycle, BUT ONCE THE 5 EVENTS AFTER SWITCHING ON, IT DOES NOT UPDATE ANYMORE (but that's another issue), so diagnostics were not easy.
Last updated: 2024-07-24
Post by timvh on RAMP_REAL FB is retaining my output value when i try to re use the FB
CODESYS Forge
talk
(Post)
I think, that if you set the timebase to T#0s, that it will be reset. But you can also make your own ramp down with a Timer (make sure the PT time is not T#0s):
Last updated: 2024-07-29
Post by flappyman on licenses question
CODESYS Forge
talk
(Post)
I hope this tread will be able to help me. I got your new licenses and it was working perfectly fine. Unfortunately, my PLC got severely damaged and it can not run anymore. Is it possible to somehow release the license so I could use it again. I have all information for the device and can provide it.
Last updated: 2024-08-05
Post by oymyakon on Modbus Lockup
CODESYS Forge
talk
(Post)
Hi i have a project where i am communicating with many modbus devices using TCP to serial. This is all working extremely well except when i turn one of the remote devices off. If i leave the auto reconnect on it still doesn't talk to the rmianing devices and if i turn Auto reconnect off it locks up. Any help would be appreciated. Paul.
Last updated: 2024-08-07
Post by oymyakon on Modbus Lockup
CODESYS Forge
talk
(Post)
Hi i have a project where i am communicating with many modbus devices using TCP to serial. This is all working extremely well except when i turn one of the remote devices off. If i leave the auto reconnect on it still doesn't talk to the rmianing devices and if i turn Auto reconnect off it locks up. Any help would be appreciated. Paul.
Last updated: 2024-08-07
Post by tk096 on gear over gear (2 masters,1 slave) - how to do it?
CODESYS Forge
talk
(Post)
Hi, you could calculate the position/dynamics of the slave axis yourself and use one of the function blocks SMC_FollowPosition/SMC_FollowSetValues to move the slave axis. https://content.helpme-codesys.com/en/libs/SM3_Basic/Current/SM3_Basic/POUs/Movement/Direct/SMC_FollowPosition.html https://content.helpme-codesys.com/en/libs/SM3_Basic/Current/SM3_Basic/POUs/Movement/Direct/SMC_FollowSetValues.html
Last updated: 2024-08-19
Post by abauza on Image Pool using in other libraries
CODESYS Forge
talk
(Post)
Hi I have done some tests and i realised that it's an issue with the visualizator simulator because i uploaded the program to a device and tried to see on the Web browser and I see correcctlu the images of the image pool of the library. I post this for anyone that have the same problem.
Last updated: 2024-08-20
Post by steven-schalm on Github Actions CI/CD tasks - development topic
CODESYS Forge
talk
(Post)
hello kevinrn, I've been looking for a solution to the CI/CD issue for a long time. Briefly about me... I am 32 and software architect for Codesys V3 and fullstack dev for web (VueJS, NestJS) in a small company in Erfurt (Germany). https://www.rex-at.de/. Through my web part, we already have CI/CD running well via GitLab (YAML-based configuration file (.gitlab-ci.yml), which defines which pipelines and jobs are executed when certain events occur) with everything you know. Stages for npm packages - prepare (GitVersion, npm install or whatever) - build (vite, tsc or whatever) - testing (vitest, jest or whatever) - deploy (npm packages) And similar for monorepo's or backend services (in NestJS) as DockerImages. For Codesys we have been building an OOP framework for years (~50 libraries now), which is currently managed via SVN and a specially written Svn-Watcher (in Python) gets commits and runs and builds everything together and deploys it to an FTP server and network drive. Why do we still have SVN? Because we are unfortunately still tied to the safety integration of Codesys and can therefore only go to SP15 at most with our controller/Eckelmann. But soon there will be an update and there will be no more obstacles to using Git. Hence my questions: 1. the basic idea is to run a local Windows Runner on some machine? 2. install Codesys on the machine where the runner is running? 3. powershell & python scripts are then used to execute builds (compile, build, sign libraries) & deploys? 4. can the Github action also be used in GitLab? ChatGPT has already told me that it's not the same, but it doesn't hurt to ask. Do you have any ideas on this? Greetings :D
Last updated: 2024-08-20
Post by taqamert on Codesys 3.5 Library Download Failed
CODESYS Forge
talk
(Post)
Hello, I need a few libraries in CoDeSys 3.5. I want to download them using the "Download Missing Library" option from the Library Manager menu. However, I keep getting a "Download Failed" error. Despite trying at different times, I haven't been able to download them. What should I do?
Last updated: 2024-08-21
Post by renezw on Access to a running Codesys instance via Python
CODESYS Forge
talk
(Post)
I have a Codesys environment running and would like to inject code into the running environment at the same time using a code generator with Python via the console. So far I can only start a new Codesys instance with Python, but not access an already running one. How can I access the running Codesys instance?
Last updated: 2024-09-03
Post by eozupek on problem con file transfer in raspberry
CODESYS Forge
talk
(Post)
I recently acquired the Opus B4 product from topcon company and encountered a "code 7" error in the Web Visu File Transfer application. I have been unable to locate the CFG files mentioned above. However, I have been able to perform streaming. I would appreciate your assistance in resolving this issue. Sincerely, Emre öZÜPEK
Last updated: 2024-09-03
Post by codesysdave on CoDeSys 3.5 SP20 "No Offline Help installed"
CODESYS Forge
talk
(Post)
What does this message mean, in the Errors/Messages box? "[ERROR] MyProjectName: No Offline Help installed" In CDS23, I used to be able to select a system function with the mouse, and press F1. Help and description would popup. How do I get so-called On-line Help installed?
Last updated: 2024-09-06
Post by kd50 on J1939 DM1 Message
CODESYS Forge
talk
(Post)
Hi all, I am new to J1939 and DM1 field. I would like to work on this topic at my office. Could anyone please give me some information about how l can practice on DM1 topic at my office? Is there any small product l can buy so that l could practice on it? Thanks
Last updated: 2024-09-18
Post by kd50 on J1939 DM1 Message
CODESYS Forge
talk
(Post)
Hi all, I am new to J1939 and DM1 field. I would like to work on this topic at my office. Could anyone please give me some information about how l can practice on DM1 topic at my office? Is there any small product l can buy so that l could practice on it? Thanks
Last updated: 2024-09-18
Post by anlebr on Codesys Communication Manger - Required information model version exists in the model repository but is not found
CODESYS Forge
talk
(Post)
Hi I posted the same question at Wago Community. PatrickR told me to use an older version of the nodesets. I dont remember exactly what I did, but I am quite sure this somehow led to a solution. Hope this helps :)
Last updated: 2024-09-18
Post by garmusd on Raspberry Pi 5 GPIO not working.
CODESYS Forge
talk
(Post)
Hi, Codesyscontrol 4.13.0.0 Raspberry Pi5 64bit with latest updates. Cant get working GPIO - no output and no input. SPI/I2C not tested. GPIOs B+/Pi2, Input/Output is set in the parameters, assigned variables int the Mapping. Absolutely no reaction. Do I need to configure anything else to make it work? Thanks!
Last updated: 2024-09-26
Post by timvh on FB string and naming
CODESYS Forge
talk
(Post)
Really not clear what you are trying to do, but isn't a Struct enough? So add an object of the type DUT to the Application. Then create a structure TYPE ST_Sensor : STRUCT sName : STRING; uiNumber : UINT; END_STRUCT END_TYPE Then in you application add an instance of this Structure stSensor1 : ST_Sensor := (sName := 'my sensor', uiNumber := 1); or use it like this stSensor1.sName := 'my sensor';
Last updated: 2024-09-28
Post by jwhaley on C0007 Errors
CODESYS Forge
talk
(Post)
Hi all. I'm pretty new to codesys. Maybe a few months. I've had on and off issues here and there. This issue I cant figure out. The top line is one of 2 that I had. The other one has mysteriously left. the 2nd and 3rd showed up after I restarted the program. I'm not sure how to take care of them. Please help!
Last updated: 2024-10-03
Post by tdaf on Codesys KNX Demo limitations
CODESYS Forge
talk
(Post)
Hello to all. I am testing the Codesys KNX package using a raspberry pi to determine if it fits my needs. Does anyone know the limitations of the package when you use it without a license? I searched for it myself but couldn't find any information on the matter. Thank you all for your help.
Last updated: 2024-10-05
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND
or OR
.