Post by brandonje on [Error] IoDrvEtherNetIP Library with Weintek CODESYS Forge talk (Post)
I'm using weintek and Codesys V3.5 SP22 when I try to charge an ethernetIP device show me this error: ------ Build started: Application: Device.Application ------- Typify code... [ERROR] cip object, 4.9.0.0 (codesys): TCPIP_Interface: C0231: Expression of type 'BOOL' expected in this place [ERROR] cip object, 4.9.0.0 (codesys): TCPIP_Interface: C0077: Unknown type: '(_pPhysicalLink^._xLinkState <> CmpSysEthernet.OperStatus.SYSETH_OPERSTAT_Up)' [ERROR] cip object, 4.9.0.0 (codesys): TCPIP_Interface: C0077: Unknown type: 'CmpSysEthernet.OperStatus.SYSETH_OPERSTAT_Up' [ERROR] cip object, 4.9.0.0 (codesys): TCPIP_Interface: C0062: 'CmpSysEthernet.OperStatus' is no structured variable [ERROR] cip object, 4.9.0.0 (codesys): TCPIP_Interface: C0063: 'CMPSYSETHERNET, 3.4.3.0 (3S - SMART SOFTWARE SOLUTIONS GMBH)' contains no definition for 'OperStatus' [ERROR] cip object, 4.9.0.0 (codesys): SendEthFrame [TCPIP_Interface]: C0077: Unknown type: 'SysEthernetFrame' [ERROR] cip object, 4.9.0.0 (codesys): SendEthFrame [TCPIP_Interface]: C0046: Identifier '_diAdapterNumber' not defined [ERROR] cip object, 4.9.0.0 (codesys): SendEthFrame [TCPIP_Interface]: C0032: Cannot convert type 'Unknown type: '_diAdapterNumber'' to type 'DINT' [ERROR] cip object, 4.9.0.0 (codesys): SendEthFrame [TCPIP_Interface]: C0032: Cannot convert type 'Unknown type: 'ADR(ethFrame.ethData)'' to type 'POINTER TO StructEthernetframe' [ERROR] cip object, 4.9.0.0 (codesys): SendEthFrame [TCPIP_Interface]: C0077: Unknown type: 'ethFrame.ethData' [ERROR] cip object, 4.9.0.0 (codesys): SendEthFrame [TCPIP_Interface]: C0077: Unknown type: 'SysEthernetFrame' [ERROR] cip object, 4.9.0.0 (codesys): SendEthFrame [TCPIP_Interface]: C0032: Cannot convert type 'Unknown type: 'ethFrame.udFrameLen'' to type 'ANY' [ERROR] cip object, 4.9.0.0 (codesys): SendEthFrame [TCPIP_Interface]: C0077: Unknown type: 'SysEthernetFrame' [ERROR] cip object, 4.9.0.0 (codesys): _OpenEthAdapter [TCPIP_Interface]: C0032: Cannot convert type 'Unknown type: '((driverInstance * 2) + 1)'' to type 'ANY' [ERROR] cip object, 4.9.0.0 (codesys): _OpenEthAdapter [TCPIP_Interface]: C0077: Unknown type: '(driverInstance * 2)' [ERROR] cip object, 4.9.0.0 (codesys): _OpenEthAdapter [TCPIP_Interface]: C0077: Unknown type: 'driverInstance' [ERROR] cip object, 4.9.0.0 (codesys): _OpenEthAdapter [TCPIP_Interface]: C0046: Identifier 'driverInstance' not defined [ERROR] cip object, 4.9.0.0 (codesys): SendFrame [TCPIP_Interface]: C0077: Unknown type: 'SysEthernetFrame' [ERROR] cip object, 4.9.0.0 (codesys): SendFrame [TCPIP_Interface]: C0231: Expression of type 'BOOL' expected in this place [ERROR] cip object, 4.9.0.0 (codesys): SendFrame [TCPIP_Interface]: C0077: Unknown type: 'SIZEOF(ethFrame.ethData)' [ERROR] cip object, 4.9.0.0 (codesys): SendFrame [TCPIP_Interface]: C0077: Unknown type: 'ethFrame.ethData' [ERROR] cip object, 4.9.0.0 (codesys): SendFrame [TCPIP_Interface]: C0077: Unknown type: 'SysEthernetFrame' [ERROR] cip object, 4.9.0.0 (codesys): SendFrame [TCPIP_Interface]: C0018: 'ethFrame.udFrameLen' is no valid assignment target [ERROR] cip object, 4.9.0.0 (codesys): SendFrame [TCPIP_Interface]: C0077: Unknown type: 'SysEthernetFrame' [ERROR] cip object, 4.9.0.0 (codesys): SendFrame [TCPIP_Interface]: C0032: Cannot convert type 'Unknown type: 'ADR(ethFrame.ethData)'' to type 'POINTER TO BYTE' [ERROR] cip object, 4.9.0.0 (codesys): SendFrame [TCPIP_Interface]: C0077: Unknown type: 'ethFrame.ethData' [ERROR] cip object, 4.9.0.0 (codesys): SendFrame [TCPIP_Interface]: C0077: Unknown type: 'SysEthernetFrame' [ERROR] cip object, 4.9.0.0 (codesys): SendFrame [TCPIP_Interface]: C0201: Type 'SysEthernetFrame' is not equal to type 'SysEthernetFrame' of VAR_IN_OUT respectively REFERENCE 'ethFrame' [ERROR] cip object, 4.9.0.0 (codesys): _CloseEthAdapter [TCPIP_Interface]: C0046: Identifier 'ethClose' not defined [ERROR] cip object, 4.9.0.0 (codesys): _CloseEthAdapter [TCPIP_Interface]: C0018: 'ethClose' is no valid assignment target [ERROR] cip object, 4.9.0.0 (codesys): _CloseEthAdapter [TCPIP_Interface]: C0046: Identifier '_diAdapterNumber' not defined [ERROR] cip object, 4.9.0.0 (codesys): _CloseEthAdapter [TCPIP_Interface]: C0032: Cannot convert type 'Unknown type: '_diAdapterNumber'' to type 'DINT' [ERROR] cip object, 4.9.0.0 (codesys): _CloseEthAdapter [TCPIP_Interface]: C0046: Identifier '_diAdapterNumber' not defined [ERROR] cip object, 4.9.0.0 (codesys): _CloseEthAdapter [TCPIP_Interface]: C0018: '_diAdapterNumber' is no valid assignment target [ERROR] cip object, 4.9.0.0 (codesys): _CloseEthAdapter [TCPIP_Interface]: C0046: Identifier '_stName' not defined [ERROR] cip object, 4.9.0.0 (codesys): _CloseEthAdapter [TCPIP_Interface]: C0018: '_stName' is no valid assignment target [ERROR] cip object, 4.9.0.0 (codesys): _CloseEthAdapter [TCPIP_Interface]: C0046: Identifier '_stDescription' not defined [ERROR] cip object, 4.9.0.0 (codesys): _CloseEthAdapter [TCPIP_Interface]: C0018: '_stDescription' is no valid assignment target [ERROR] cip object, 4.9.0.0 (codesys): AddressConflictDetection [TCPIP_Interface]: C0231: Expression of type 'BOOL' expected in this place [ERROR] cip object, 4.9.0.0 (codesys): AddressConflictDetection [TCPIP_Interface]: C0077: Unknown type: '(_pPhysicalLink^._xLinkState = CmpSysEthernet.OperStatus.SYSETH_OPERSTAT_Up)' [ERROR] cip object, 4.9.0.0 (codesys): AddressConflictDetection [TCPIP_Interface]: C0077: Unknown type: 'CmpSysEthernet.OperStatus.SYSETH_OPERSTAT_Up' [ERROR] cip object, 4.9.0.0 (codesys): AddressConflictDetection [TCPIP_Interface]: C0062: 'CmpSysEthernet.OperStatus' is no structured variable [ERROR] cip object, 4.9.0.0 (codesys): AddressConflictDetection [TCPIP_Interface]: C0063: 'CMPSYSETHERNET, 3.4.3.0 (3S - SMART SOFTWARE SOLUTIONS GMBH)' contains no definition for 'OperStatus' [ERROR] cip object, 4.9.0.0 (codesys): Recv [TCPIP_Interface]: C0077: Unknown type: 'SysEthernetFrame' [ERROR] cip object, 4.9.0.0 (codesys): Recv [TCPIP_Interface]: C0046: Identifier '_diAdapterNumber' not defined [ERROR] cip object, 4.9.0.0 (codesys): Recv [TCPIP_Interface]: C0032: Cannot convert type 'Unknown type: '_diAdapterNumber'' to type 'DINT' [ERROR] cip object, 4.9.0.0 (codesys): Recv [TCPIP_Interface]: C0046: Identifier '_diAdapterNumber' not defined [ERROR] cip object, 4.9.0.0 (codesys): Recv [TCPIP_Interface]: C0032: Cannot convert type 'Unknown type: '_diAdapterNumber'' to type 'DINT' [ERROR] memory block manager, 3.5.21.30 (codesys): ObjectRetain [Disposable]: C0448: Operator '__XADD' is not supported by your current target. At least runtime system version 3.5.14.0 is required. [ERROR] memory block manager, 3.5.21.30 (codesys): ObjectRelease [Disposable]: C0448: Operator '__XADD' is not supported by your current target. At least runtime system version 3.5.14.0 is required. [ERROR] cip object, 4.9.0.0 (codesys): SendFrame [LLDP_Management]: C0077: Unknown type: 'SysEthernetFrame' [ERROR] cip object, 4.9.0.0 (codesys): SendFrame [LLDP_Management]: C0201: Type 'SysEthernetFrame' is not equal to type 'SysEthernetFrame' of VAR_IN_OUT respectively REFERENCE 'frame' [ERROR] cip object, 4.9.0.0 (codesys): SendFrame [LLDP_Management]: C0201: Type 'SysEthernetFrame' is not equal to type 'SysEthernetFrame' of VAR_IN_OUT respectively REFERENCE 'ethFrame' [ERROR] cip object, 4.9.0.0 (codesys): CreateFrame [LLDP_Management]: C0077: Unknown type: 'SysEthernetFrame' [ERROR] cip object, 4.9.0.0 (codesys): CreateFrame [LLDP_Management]: C0032: Cannot convert type 'Unknown type: 'ADR(frame.ethData[0])'' to type 'POINTER TO BYTE' [ERROR] cip object, 4.9.0.0 (codesys): CreateFrame [LLDP_Management]: C0077: Unknown type: 'frame.ethData[0]' [ERROR] cip object, 4.9.0.0 (codesys): CreateFrame [LLDP_Management]: C0077: Unknown type: 'SysEthernetFrame' [ERROR] cip object, 4.9.0.0 (codesys): CreateFrame [LLDP_Management]: C0032: Cannot convert type 'Unknown type: 'SIZEOF(frame.ethData)'' to type 'UDINT' [ERROR] cip object, 4.9.0.0 (codesys): CreateFrame [LLDP_Management]: C0077: Unknown type: 'frame.ethData' [ERROR] cip object, 4.9.0.0 (codesys): CreateFrame [LLDP_Management]: C0077: Unknown type: 'SysEthernetFrame' [ERROR] cip object, 4.9.0.0 (codesys): CreateFrame [LLDP_Management]: C0018: 'frame.udFrameLen' is no valid assignment target [ERROR] cip object, 4.9.0.0 (codesys): CreateFrame [LLDP_Management]: C0077: Unknown type: 'SysEthernetFrame' [ERROR] iodrvethernetip, 4.9.0.0 (codesys): Receive [UcmmReceiver]: C0448: Operator '__COMPARE_AND_SWAP' is not supported by your current target. At least runtime system version 3.5.14.0 is required. [ERROR] iodrvethernetip, 4.9.0.0 (codesys): Send [UcmmReceiver]: C0448: Operator '__COMPARE_AND_SWAP' is not supported by your current target. At least runtime system version 3.5.14.0 is required. [ERROR] iodrvethernetip, 4.9.0.0 (codesys): Enqueue [UcmmQueue]: C0448: Operator '__COMPARE_AND_SWAP' is not supported by your current target. At least runtime system version 3.5.14.0 is required. [ERROR] iodrvethernetip, 4.9.0.0 (codesys): Enqueue [UcmmQueue]: C0448: Operator '__XADD' is not supported by your current target. At least runtime system version 3.5.14.0 is required. [ERROR] iodrvethernetip, 4.9.0.0 (codesys): Enqueue [UcmmQueue]: C0448: Operator '__XADD' is not supported by your current target. At least runtime system version 3.5.14.0 is required. [ERROR] iodrvethernetip, 4.9.0.0 (codesys): Dequeue [UcmmQueue]: C0448: Operator '__XADD' is not supported by your current target. At least runtime system version 3.5.14.0 is required. [ERROR] iodrvethernetip, 4.9.0.0 (codesys): Dequeue [UcmmQueue]: C0448: Operator '__COMPARE_AND_SWAP' is not supported by your current target. At least runtime system version 3.5.14.0 is required. [ERROR] iodrvethernetip, 4.9.0.0 (codesys): Dequeue [UcmmQueue]: C0448: Operator '__XADD' is not supported by your current target. At least runtime system version 3.5.14.0 is required. [ERROR] asynchronous job manager, 5.0.0.0 (codesys): ExtendAsync [FactoryBase]: C0448: Operator '__COMPARE_AND_SWAP' is not supported by your current target. At least runtime system version 3.5.14.0 is required. Compile complete -- 71 errors, 0 warnings Build complete -- 71 errors, 0 warnings : No download possible
Last updated: 2026-08-20

Post by dantheman on Connecting to SoftPLC Only Works By Turning Off Modbus Ethernet Port CODESYS Forge talk (Post)
I have an IPC with 2 ethernet ports and 1 Wi-Fi. I'm using ModbusTCP with the ethernet port named "enp2s0" connected to my remote I/O. This works fine when testing with Python and also works with CODESYS, but CODESYS is only able to scan for the Linux SoftPLC when I turn off the "enp2s0" interface. In other words, I can't get online with the IDE if I want my ModbusTCP comms to run with CODESYS. I'm using a Linux SoftPLC that has the following entry in CODESYSControl.cfg, hoping that this will allow me to connect with "enp1s0" or "wlp3s0", and leave "enp2s0" for field comms, but this seems to only make the source IP of the ModbusTCP comms to be bound to "enp2s0". That last point is the case only if I don't restart the service, but if I do restart the service after changing the config file, the source IP for the ModbusTCP comms then becomes the one for "enp1s0", which is very confusing to me: [SysSocket] Adapter.0.Name="enp2s0" Adapter.0.EnableSetIpAndMask=1 On the device list, I only have "enp2s0" given as the ethernet device that has the ModbusTCP master & slave beneath it, shown in Screenshot 1. On the IPC, I can ping the ModbusTCP client (remote I/O) from "enp2s0", and I've attached a Wireshark capture of running ModbusTCP from the CODESYS runtime as Screenshot 2, 3 & 4 (again, I can't get online when this is running, I have to turn off "enp2s0" to connect even when it's idle and I don't have an active TCP session with my Python tests). Like I explained above, the source IP is "enp1s0", even though the ethernet device on the project is "enp2s0". I was lucky to catch the red message that showed the source IP that makes sense to me (the one for "enp2s0"), but for some reason that connection was reset and I never saw that packet again. I've also tried this with Auto-reconnect both enabled & disabled, for the ModbusTCP Master device. I also have to turn off "enp1s0" and then turn it on, just so that I can have the ModbusTCP comms running from "enp2s0" (which is not intuitive in any way to me, I'd love some help understanding that phenomenon as well) in the weird manner that I've described above. I would be very appreciative if someone can help me figure out this pickle. I'd love to just connect to CODESYS through my Wi-Fi interface and leave my ethernet ports for field comms.
Last updated: 2024-08-01

Post by thn-power on Updating OPC UA Core Nodeset on PLS CODESYS Forge talk (Post)
Hi After much trail and error I think I found the root cause to my OPC UA problem. The problem is that I cannot manage to build and download a program with a a custom OPC UA Information model. We use a Weidmueller WL2000 PLS, but the problem also exsist on the Win V3 PLC. Our custom information model is based on the latest versions of the OPC UA Core Nodeset v 1.05.03 (2023-09-20) and UA/DI nodeset 1.04.0 (2022-11-03) Those nodesets are installed in the Codesys Information Model Repository (3.5.19.6) However, when trying to build I get the following error. [ERROR] Untitled1: Communication Manager [Device: PLC Logic: Application]: The information model http://opcfoundation.org/UA/ is required by http://bos.org/ with a minimal publication date from 15.12.2023 but the device has only a model from 15.09.2021 installed. Probably the information model from 15.09.2021 is missing in the information model repository. [ERROR] Untitled1: Communication Manager [Device: PLC Logic: Application]: The information model http://opcfoundation.org/UA/DI/ is required by http://bos.org/ with a minimal publication date from 03.11.2022 but the device has only a model from 09.03.2021 installed. Probably the information model from 09.03.2021 is missing in the information model repository. Build complete -- 2 errors, 1 warnings : No download possible I think the problem is that the UA Core nodeset is implemented in the PLC firmware (at least that in Siemens S7), and that only includes the "old" nodeset from 2021-09-21 etc. So the question is, how (or if?) can I transfer the new nodeset to the PLS? I have created separate Information models under Communication manager with the newer code nodesets (UA and DI). But it seems that the compiler does not recognize them being excising, neither in the Codesys IDE or on the PLC. Would have guessed that this is a common issue, sine many manufacturers use the latest versions of the OPC UA standard, and that it would be a solution to the problem.
Last updated: 2024-09-20