Post by eschwellinger on TargetVisu controls are incorrectly positioned
CODESYS Forge
talk
(Post)
yes this is a bug, please disable the overlay functionality in the Visualisation Manager in your project
Last updated: 2024-11-03
Post by ben1 on Access Variable Visu Dialog
CODESYS Forge
talk
(Post)
Tough to know exactly what you are asking for here. Can you give a more thorough explanation and/or provide snips?
Last updated: 2024-11-17
Post by kdasystems on WebVisu on mobile devices
CODESYS Forge
talk
(Post)
Hello I have a problem with web visu. When I open it to normal screen it is with good quality, but when I use it on mobile phone or tab then it is really bad quality, almost not possible to read the information. Can somebody help me what are the exact settings in the visu manager for this
Last updated: 2023-09-13
Post by bjarne-pagaard on Multiple WebVisu
CODESYS Forge
talk
(Post)
You can use the switch frame variable, but there should be a variable for each active visu user. You can put the switch frame variable in an array, and use CURRENTCLIENTID as index into the array to get what you want. The CURRENTCLIENTID is assigned to new users automagically by the Visu Management.
Last updated: 2024-03-14
Post by tortillamarcal on TargetVisu Freezing
CODESYS Forge
talk
(Post)
Hi, I have project that worked during months. This one have targetvisu where I move between screens with a frame using the function flick/slide. The last weeks when i move sliding the screen freeze but the comutation tag of the frame continue registration the movements. The program continue working at the background but the screen freeze. Has anyone encountered something similar? Thanks!
Last updated: 2024-09-12
Post by hafizapik99 on Webvisu not showing Codesys V3.5 SP13 Patch 4
CODESYS Forge
talk
(Post)
Hello, I am using a Hitachi Micro EHV+ for a small project, and I wanted to have a Web visu, done with Codesys V3.5 SP13 Patch 2. I test the Visu screen and it works well in Codesys, but I get a blank page when i enter the web visu in a browser. Here is the setting under web visualization: Update rate (ms): 5000 (previously set to 2500 also not working) Default communication size: 100000 (previously set to 50000 also not working) Under Visu_Task tab: Priority: 3 The Visu_Task interval is set to 2500ms (previously set to 200ms also not working) I'm using Google chrome with the latest update, the Javascript is enabled with HTML5. Any advice?
Last updated: 2024-04-06
Post by hafizapik99 on Webvisu not showing Codesys V3.5 SP13 Patch 2.
CODESYS Forge
talk
(Post)
Hello, I am using a Hitachi Micro EHV+ for a small project, and I wanted to have a Web visu, done with Codesys V3.5 SP13 Patch 2. I test the Visu screen and it works well in Codesys, but I get a blank page when i enter the web visu in a browser. Here is the setting under web visualization: Update rate (ms): 5000 Default communication size: 100000 Under Visu_Task tab: Priority: 3 The Visu_Task interval is set to 2500ms I'm using Google chrome with the latest update, the Javascript is enabled with HTML5. Any advice?
Last updated: 2024-04-06
Post by deeps on web visu on IFM
CODESYS Forge
talk
(Post)
I have an IFM cr1077 display. I would like to show B&R mapp view on IFM visualization. I used coedsys web browser elemnt for this. I could see IFM working fine in Internet web browser but IFM device shows white screen and freezes. I think there is problem with IFM showing the web browser. Is my understanding of the web visu right? am I doing any mistake here?
Last updated: 2023-08-18
Post by timvh on Specify Input Configuration "OnDialogClosed" Action to only react to certain Dialogs
CODESYS Forge
talk
(Post)
What maybe helps is the Visu Dialog ST demo project: https://store.codesys.com/en/visu-dialog-st.html This has an application IECOpenDialog where dialogs are opened using the VU.FbOpenDialogExtended function blocks. The fbOpenConfigurationDialog call has a reference (interface) to the "close listener" FB of which it's method is automatically called when the dialog is closed. This way you can create specific function blocks for each dialog when it is closed and do what you want with the data that might have been changed.
Last updated: 2023-09-28
Post by robpqs on Visual error with cut/shredded texts
CODESYS Forge
talk
(Post)
Hello, This is an old topic but it might help. This can/should be solved by either of the solution below 1. disabling the "Support client animations and overlay of native elements" option in the visualization Manager (which is handy) 2. disabling the "Hardware acceleration" of the browser. Saw it happening on some clients/PC and on other it works fine with the same webvisu... (Version 3.5.19.20 with visu package 4.4.0.0) Hopefully it will be fixed it in a next release. I haven't tested the 4.5.0.0 visu packages yet. RP,
Last updated: 2024-05-27
Post by paro on "You are using inconsistent overlay settings, please check your compiler defines for the current application" error
CODESYS Forge
talk
(Post)
Disable the setting "Support client animations and overlay of native elements" in the Visu Manager. Activating this setting should also set a compiler define (GENERATE_OVERLAY_VISU). Maybe the compiler define is set and the feature is not activated in the visu manager or or the other way round.. rightclick the Application -> Properties -> Build https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_dlg_properties_build.html
Last updated: 2024-05-29
Post by rabaggett on No Visu on RasPi
CODESYS Forge
talk
(Post)
OK, I got this to work as shown above in mos89p's comment. What I did: Tools/Update Raspberry Pi. Reloading the runtime seems to have solved the web problem. I can view the visualization on the Pi and laptop using a browser as shown above. Thanks! But Isn't the visualization supposed to take over the screen of the Raspi? When I run visu projects on Windows or Wago, the visualization shows on that device's screen by default.. But this is not happening in this case
Last updated: 2024-06-20
Post by jeffg on License issue with visu tags
CODESYS Forge
talk
(Post)
I seem to be having a problem with the license on ver 3.5.19 patch 5 The runtime keeps going into demo mode but it wont tell me the reason I looked at the license software metrics and the visu doesn't appear to be working I attached screen shots of the metrics screen and the license dongle that is plugged in to the windows PC Anyone have any ideas on how to fix this
Last updated: 2024-06-28
Post by dkugler on TargetVisu Freezing
CODESYS Forge
talk
(Post)
The only weird situation i remeber with particular or complete frozen target visu was after the rtc clock was fallen or set back to the past. It looked like after running a while the alarm history database crashed during writing entries at a date lot of years in the past. After setting the rtc clock to actual date/time and deleting the alarm db every thing worked fine. I don't know, if this is/was a problem of our PLC hardware/firmware? Maybe check date/time at your system?
Last updated: 2024-09-13
Post by jddaigle on TargetVisu controls are incorrectly positioned
CODESYS Forge
talk
(Post)
Hello, I'm trying to run TargetVisu on my Linux IPC, and while it does work, the controls are misaligned compared to my WebVisu. Both visualizations are full-screen on a Debian 12 VM with a resolution of 1280x768. The WebVisu is running in Firefox. Are there any configuration I should adjust to ensure the controls align properly between the two? Any guidance or troubleshooting tips would be greatly appreciated! Thank you.
Last updated: 2024-11-03
Post by durallymax on Access Variable Visu Dialog
CODESYS Forge
talk
(Post)
Is there a way to access the variable in the called dialog? Example: Text Field element with PLC_PRG.myVar as Text variable. OnMouseClick configured to write variable with keypad pop-up. OnValueChanged configured to Execute ST RND(PLC_PRG.myVar,2); Rather than change myVar with each copy of this Text Field, is there a way to access whatever the configured text variable is? Generally try to stay away from ST in visu, but was curious regardless.
Last updated: 2024-11-14
Post by snhatton on Visu - changing auto-logout time
CODESYS Forge
talk
(Post)
You could try using the VUM_UserGroup struct from the VisuUserManagement library. I haven't tried this, but there is a variable for tAutoLogout to set the logout time.
Last updated: 2023-12-11
Post by mavitia on Issue with TargetVisu on Codesys Control Win
CODESYS Forge
talk
(Post)
I am having exactly the same problem, I created a Ticket, and will post whenever I get a solution for the problem.
Last updated: 2024-01-29
Post by paro on Multiple WebVisu
CODESYS Forge
talk
(Post)
Hi, they should be independent when "Use CurrentVisu variable" is unchecked in the visu manager.. maybe you can give us more infos when its not the case.
Last updated: 2024-01-30
Post by mavitia on Issue with TargetVisu on Codesys Control Win
CODESYS Forge
talk
(Post)
anyone else running into the same issue: perform a repair install on the runtime, that should fix it without affecting license.
Last updated: 2024-02-02
Post by alink on Visu - changing auto-logout time
CODESYS Forge
talk
(Post)
decleration: fbVisuUserMgmt : VisuUserManagement.VUMUserGroup; bAutoLogOff : BOOL; tAutoLogOffTime : TIME; wstGroupName : WSTRING; code: fbVisuUserMgmt.wstGroupName := wstGroupName; fbVisuUserMgmt.xAutoLogout := bAutoLogOff; fbVisuUserMgmt.tAutoLogout := tAutoLogOffTime; Tried it that way. But how to execute? Doing fbVisuUserMgmt() dosn't work. Maybe silly question, but I'm a bit unexperienced
Last updated: 2024-02-07
Post by macros8 on Visualization using methods and cyclic ST-calls
CODESYS Forge
talk
(Post)
Have you found the way how to call any function in case the visu is opened? Like on event when the screen is opened to initialize some variables etc.? I can´t... :/
Last updated: 2024-03-01
Post by k2saki on Table How to set row number from 1 ( not from 0)
CODESYS Forge
talk
(Post)
In Codesys visu, Table row number always start from 0. How do I set row number from 1 ?
Last updated: 2024-05-25
Post by arrotek on Codesys HMI Redundancy
CODESYS Forge
talk
(Post)
Is there a way to run Codesys HMI on two different PC's and have the web visu clients fail over to the HMI instance that is wokring or running?
Last updated: 2024-05-30
Post by pmolke on Einheiten umrechnen, Numpad und Eingabegrenzen
CODESYS Forge
talk
(Post)
Ich habe das für die Visu anders gelöst. Ich nehme ein Dialog welches Stunden, Minuten und Sekunden einzeln hoch/herunter wählen lässt. Das Ergebnis wird nachdem bestätigen automatisch übergeben. Ich hab mir es aus dem Wagomacros abgeschaut.
Last updated: 2024-06-21