Search talk: boolean operator priority and order

 
<< < 1 .. 131 132 133 134 135 .. 152 > >> (Page 133 of 152)

Post by e13740e on Parameterized Property syntax for array element processing CODESYS Forge talk (Post)
Hello. I'm trying to create a Parameterized Property(CDS V3.5 SP21) to avoid copy-pasting code for processing array elements. I can't seem to get any result. Perhaps I am making a mistake with the syntax. None of the declaration options below are accepted by the compiler. If you know and use them (Parameterized Properties) in your work, please let me know. Thank you in advance. Option 1: PROPERTY <property_name> : <data_type> VAR_INPUT <index_name> : <index_type>; // One or more index parameters are declared here END_VAR</index_type></index_name></data_type></property_name> GET Code that uses <index_name> to return a value END_GET</index_name> SET Code that uses <index_name> and the implicit variable <property_name> to write a value END_SET</property_name></index_name> END_PROPERTY Option 2: PROPERTY <property_name> (<index_name> : <index_type>) : <data_type></data_type></index_type></index_name></property_name> GET Code that uses <index_name> to return a value END_GET</index_name> SET Code that uses <index_name> and the implicit variable <property_name> to write a value END_SET</property_name></index_name> END_PROPERTY
Last updated: 2025-10-09

Post by e13740e on Parameterized Property syntax for array element processing CODESYS Forge talk (Post)
Hello. I'm trying to create a Parameterized Property(CDS V3.5 SP21) to avoid copy-pasting code for processing array elements. I can't seem to get any result. Perhaps I am making a mistake with the syntax. None of the declaration options below are accepted by the compiler. If you know and use them (Parameterized Properties) in your work, please let me know. Thank you in advance. Option 1: PROPERTY <property_name> : <data_type> VAR_INPUT // One or more index parameters are declared here <index_name> : <index_type>; END_VAR</index_type></index_name></data_type></property_name> // Accessor for reading GET // Code that uses <Index_Name> to return a value END_GET // Accessor for writing SET // Code that uses <Index_Name> and // the implicit variable <Property_Name> to write a value END_SET END_PROPERTY Option 2: PROPERTY <property_name> (<index_name> : <index_type>) : <data_type></data_type></index_type></index_name></property_name> // Accessor for reading GET // Code that uses <Index_Name> to return a value END_GET // Accessor for writing SET // Code that uses <Index_Name> and // the implicit variable <Property_Name> to write a value END_SET END_PROPERTY
Last updated: 2025-10-09

Post by mavitia on Application based license problem - Modbus TCP CODESYS Forge talk (Post)
I am running ubuntu on a raspberry pi, and installed an application based license Control Basic M on it, it runs a demo program fine, does not timeout etc. however, when I add a modbus TCP device, I start getting errors: <Entry severity="error" component="CmpApp" user="nobody" timestamp="12/18/2023 3:49:42 PM" infoId="24">Online change denied. Application Application is in exception state!</Entry> <Entry severity="error" component="CmpApp" user="nobody" timestamp="12/18/2023 3:49:42 PM" infoId="68">Download failed: Application=Application</Entry> <Entry severity="exception" component="CmpApp" user="nobody" timestamp="12/18/2023 3:49:41 PM" infoId="0">Application app=Application has invalid license metrics!</Entry> the modbus tcp slave runs, and the counter ticks up, however, when I call the variables on the %IX0.0 in my program, and try to upload the changes, I am getting the error messages which stop the program as far as I understand, the application based, M includes 2 fieldbus instances, but on the other side is fairly new, anything obvious I am missing out here?
Last updated: 2023-12-18

Post by giackanto on Eoe issues with Windows and Linux CODESYS Forge talk (Post)
Hello, I've been trying to use EoE for communication between a Windows PC and an M753 drive from Control Technique. Despite following some online guides (https://content.helpme-codesys.com/en/libs/EtherCATStack/4.3.0.0/Ethernet_over_EtherCAT/fld-Ethernet_over_EtherCAT.html) I haven’t had any success. Both are connected to a Debian device where RTE is running: The PC is connected via the Ethernet port. The drive is connected via the EtherCAT port. I'm unable to ping the drive from my Windows PC. Here is my configuration: On Debian: (See attachments 1, 2, 3) enp1s0 = Ethernet port enp2s0 = EtherCAT port tap2 = TAP device IP forwarding and routes are both configured. On Windows: (See attachments 4, 5) On Codesys: (See attachments 6, 7) Version: Windows 11 Debian GNU/Linux 11 Codesys 3.5.17 Control for Linux SL 4.7.0 EtherCAT 4.4.0 With this configuration, I can ping the TAP device, but not the drive (See attachment 8). Could someone explain how to properly configure all these settings? Thank you, GA
Last updated: 2023-12-19

Post by spiessli on Softmotion axis to CANopen Maxon IDX drive CODESYS Forge talk (Post)
Thanks for the advise, indeed, this was somewhat, what my intention was. I tried around again with EDSes and DCFs, anyway. It appears that the DCFs end up in a subfolder in the attach device dialog. Astonishingly, when attaching the DCF version I get a device in the device tree, where I can add a SoftMotion axis, whereas when I attach the device not in the subfolder, then I cannot. Further astonishingly, when looking in the CANopen parameters in supported profiles, "402" is listed in the case of the DCF variant, whereas in the EDS variant "0" is shown. Comparing EDS and DCF files I cannot guess, where the difference is coming from. I cannot tell either why I have always attached the EDS variant and apparantly never the DCF variant. As I am not in the lab right now, I cannot test if the connection actually is working. Thanks again, spiessli
Last updated: 2024-01-07

Post by levih on DocScripting CODESYS Forge talk (Post)
Hello I'm trying to use the DocScripting collection in Codesys. I've made it work on one PC(1) for the 3.5.16.4 version of the script collection. But when I try the same setup on another PC(2), I get an error message: Error loading Python DLL: D:\SCRIPTING\3.5.16.40\python27.dll (error code 14001) My setup on both PC's is thus: 1. Downloaded and installed Python 2. Copied the folder with the scripting collection to C: (because of admin rights) 3. Placed my .library file in the same folder as the scripting collection Only difference is that Python is v3.12.0 on PC1 and v3.12.1 on PC2. I thought maybe it was something with Python, but then I have tried using the scripting collection from 3.5.16.1, and that seems to work. Just not for scripting collection 3.5.16.4. I also can't seem to find any scripting collections on newer versions of Codesys? (e.g. 3.5.19.10) Thanks in advance!
Last updated: 2024-01-22

Post by toby on Ethernet/IP communication with Omron NX1P2 CODESYS Forge talk (Post)
Hey guys, I'm very much a noob with networking, it's my achillies heel, and this is my first networking project using Ethernet/IP. Any help offered is GREATLY appreciated. I'm trying to network a Codesys Project with an Omron NX1P2 PLC. I'm using EIP due to hardware restrains. I've added the fieldbus, EIP scanner (as the master), and made a Network Variable List. On the Sysmac Studio end, I've made the variables and set them to network inputs/outputs, registered them in EIP settings, but when I try to set the target device (the Codesys project), I suspect I need to import an EDS file for the EIP mapping. Back in the Codesys project, I'm not sure how to: - Make an EDS file to share with Sysmac Studio - How to link the target device (Omron PLC) to the EIP fieldbus - How to map the inputs from the Omron PLC. Im sorry for my very open request for help, i'm kind of lost looking through the various forums/video/tutorials as many of them dont match what im trying to do. Any help, or sample programs would be so so greatly appreciated. If you need any further clarifications, please feel free to ask. Thanks in advance, Toby
Last updated: 2024-01-24

Post by acc00 on Main Task cycle too long leading to PLC Fail CODESYS Forge talk (Post)
I have 2 Wago PFC200 PLC, running with Runtime SP19 Patch 5, with the Redundant application. The PLC communicates as Modbus Master with at this moment 15 Modbus Slaves -later there will be 28 in total- (Drives, Power management units,...). These devices are connected in 2 rings (1 ring of Drives, 1 ring of Power Management units), with 2 Managed Moxa Switches being part of the ring. Each PLC is connected to one of these switches. The issue I'm encountering is that the Cycle time of the Active PLC goes very high when I'm closing the Drive ring (simulating an issue on one Cabinet supply, resulting in that one Drive shut down, which can happen on field quite often). As a result of this long cycle, the PLC fails and goes to Exception, and the Passive PLC does not take control of the system. A normal cycle is around 30ms for the Main task, and a few ms for the Ethercat task. When I monitor with Profiler, I see that in this Maximum Cycle, the main Task is only taking 13ms, so I'm not sure where the PLC is hanging for so long. Is the remaining cycle time the Redundant management/sync or something else? Thank you in advance.
Last updated: 2024-03-08

Post by zoronoa on J1939.ReceiveWatchdog & J1939.ReceiveParameterGroup CODESYS Forge talk (Post)
Hi, I'm trying to monitor a specific PGN which I have it sending a pulse every 500mS Problem: Using the Watchdog for the ECU does not really help me as I have multiple instances with separate PGNs, if a PGN goes ghost, the ECU watchdog won't be flagged as the others will be running. I found the J1939.ReceiveWatchdog & J1939.ReceiveParameterGroup function blocks and they seem like a good solution for my problem, I just can't get them to work from my understanding you just build the J1939.ReceiveParameterGroup once and then connect it's output to the J1939.ReceiveWatchdog, here's my CODE for the setup HEARTBEAT_TIMER(IN:= TRUE, PT:= T#1000MS); //turn-on delay because of initialization race IF HEARTBEAT_TIMER.Q= TRUE THEN Glob_Var.DisplayReceive.xExecute:= TRUE; Glob_Var.DisplayReceive.itfECU:= Valve_X; Glob_Var.DisplayReceive.dwPGN:= 65511; Glob_Var.DisplayWatchdog.xEnable:= TRUE; Glob_Var.DisplayWatchdog.itfParameterGroup:= Glob_Var.DisplayReceive.itfParameterGroup; Glob_Var.DisplayWatchdog.tTimeout:= T#1500MS; END_IF Notes: Glob_Var.DisplayReceive is of type J1939.ReceiveParameterGroup Glob_Var.DisplayWatchdog is of type J1939.ReceiveWatchdog The above code is done once and not cyclically I'm monitoring Glob_Var.DisplayWatchdog.xError cyclically
Last updated: 2024-03-13

Post by jrsantab on Remote connection to ifm PLC & HMI CODESYS Forge talk (Post)
We have finally solved the problem. The version of the Gateway in the computer that worked (3.5.11.0) and the one that didn't (3.5.17.30) was different. We have three different Codesys 3.5 versions installed because we work with different controllers. I believe that, depending on the sequence you follow to install the versions you get a different Gateway version. To solve the problem you first have to disable the "obsolete" services. Open services, serach for (in our case) CODESYS Gateway V3 Version 3.5.11.0 CODESYS ServiceControl Version 3.5.11.0 I stopped the services and changed to Manual Start. Then you have to create the new services. In our case, from a Command Prompt session (cmd): SC CREATE "Codesys GatewayService Rigual" binpath="C:\Program Files\CODESYS 3.5.17.30\GatewayPLC\GatewayService.exe" and then SC CREATE "CODESYS ServiceControl Version 3.5.17.30" binpath="C:\Program Files\CODESYS 3.5.17.30\GatewayPLC\CODESYSControlService.exe" remember also to set them as Automatic Start!
Last updated: 2024-04-22

Post by xnoop on MBTCP Slave configuration CODESYS Forge talk (Post)
Hello, I use Codesys 3.5 SP18 Patch 4 (64 bit) My Codesys project is composed of several dozen of Modbus TCP Slaves. I want to configure each of them by define : - Modbus TCP Slave Configuration : Name, IPAddress, port - Channels - Mapping I can't afford to configure manually and I need to find automatic way What possibilities does the Codesys offer? 1. I know it possible to use python script to create Modbus TCP Master and Slave. But I don't find anyway to create Channels and Mapping through the API 2. I 've tested to set mapping with file.csv on a Modbus Tcp Slave, but no way to import channels definition from file 3. I 've tried to use PLCOpenXml file. For example I 've create a project with an Ethernet device. I've exported it in PlcOpenXml file. After delete the Ethernet device, I've imported the PlcOpenXml file without success. I've tried the same by creating Modbus TCP Slave. Could you help me to find to good way ? Thanks
Last updated: 2024-06-19

Post by mp9876 on Problem using MeasureFrequence FB CODESYS Forge talk (Post)
Hi everyone, new at Codesys and PLC programming in general. I am using Codesys Win V3.5 SP20 I would like to measure an encoder's frequency output (obtaining that pulse train from Factory IO) and intended to use the MeasureFrequence FB (Intern/CAA/Utilities/CAA Mathematics/3.5.19.0). As mentioned in the title what I need to measure is low frequency, such as lower than 40hz (a cycle every 25mS) or so; I could even go lower frequency if required as this is for test purposes) therefore I am not expecting problem measuring a low frequency with that FB The library in question appears to be installed as I can retrieve it from the Library Repository. I can also see it from the Device's Library Manager. Problem arises when I am trying to instantiate this particular FB. I go like this: VAR MeasF:MeasureFrequence; END_VAR Please note that as soon as I start typing the "MeasureFrequence", the MeasureFrequence comes out as a viable option in auto-typing; seems to indicate that the FB is recognized somehow. But there is no way I can compile this as it comes back with the following: C0046: Identifier 'MeasureFrequence' not defined. Tried to rename that to ABC instead of MeasF; same issue. Possibly that the library is not properly installed ? Placeholder ? I would greatly appreciate a bit of guidance if possible. Thank you and regards, Mike
Last updated: 2024-06-24

Post by timvh on Toradex and CODESYS and licensing CODESYS Forge talk (Post)
For the Virtual Control you need to use a "Network license". The Virtual Control has parameters of which one is the reference to the license server. This can be the device itself, but you need to activate the license on the host system (not in the container). For this, CODESYS has a Network License server with WBM (web based management). See for the Network License configuration: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_license_controller_linux.html If it is only for evaluation, I would advise to use a CODESYS (USB) key and activate the license on the key. Then you still have to install the CODESYS Network License server on the host, but you don't have to activate the license as soft license on the device. The benefit is that you can easily move your license to another device when needed. Off course your device must have a free USB port available to be able to do this.
Last updated: 2025-10-20

Post by jv-certhon on Io driver Scan functionality CODESYS Forge talk (Post)
Hello, Codesys IDE is 3.5.21.30 IoDrvBase is: 3.5.17.8 I am working on implementing Codesys on our I/O product line, using the IO driver examples, and the Linux UDS socket approach. I have sucessfully created an implemetation where I have a Device with mutiple slots, on which I can plug modules. These modules represent our IO modules, and communication is successful. (For this question the assumtion can be made that Codesys commucates with 1 'master' device, which handles further communcation with the IO modules. For the next part of the question it can be assumed that the Master device has a list of which modules are attached/available) I'm now trying to implement the 'Scan for Devices...' feature, but I'm completetly lost on what to do once the IoDrvScanModules method is called in my IoDrvFB. I'm guessing that the ppConnectorList has to be filled with the found devices, but I have no idea if that is the correct approach. And Codesys is not triggering my breakpoints in the method, which makes things more difficult. I hope someone could provide some examples or guidance on what steps I should take to implement the scan feature. Thanks in advance.
Last updated: 2025-11-26

Post by t-probst on Strong Private Key Protection for Encryption Certificates CODESYS Forge talk (Post)
Hello, We are trying to implement an automated method of adding of a certificate and private key to the Windows certificate store for encrypting CODESYS projects. We want to do this so that users do not have to deal with details of certificates at all and to prevent user error. We are keen on enforcing strong private key protection since it ensures that a password is required for the certificate to be used to decrypt a CODESYS project. When we add a certificate to the certificate store and enable strong key protection using the Microsoft Management Console Certificates snap-in, it works as expected. However, through this method the user may mistakenly not enable strong private key protection. For the certificates we create programmatically (using Microsoft’s Cryptography Next Generation API in .Net 7) bag attributes are added to the certificate and key by the API. These bag attributes are as follows: Bag Attributes localKeyID: 01 00 00 00 subject=C = xx, ST = xxx, O = xxx, OU = xxx, CN = xxx issuer=C = xx, ST = xxx, L = xxx, O = xxx, OU = xxx, CN = xxx -----BEGIN CERTIFICATE----- [encoded certificate] -----END CERTIFICATE----- After using this certificate with bag attributes to encrypt a CODESYS project, it can’t be decrypted, showing this error: "The specified project could not be loaded. Possible reasons might be: - The project file is corrupted or invalid - The project has been saved with a newer version of the programming system. If this is the case, you can open the project in the corresponding version. Choose "Save as..." with the appropriate storage version, and retry again. - You may not have the necessary permissions to lad the project" We know that the bag attributes are causing the issue because if we manually edit the certificate file to remove them before using the certificate to encrypt a project, the project can be decrypted as expected. However, we are unable to automatically enforce strong key protection using this method. Here is a link to a StackOverFlow question that we have posted recently for this issue: https://stackoverflow.com/questions/76922355/enforcing-strong-private-key-protection-for-x509certificate2-objects-in-net-mod Any help is greatly appreciated.
Last updated: 2023-08-22

Post by bbm1995 on Camera RTSP Feed CODESYS Forge talk (Post)
Hi dgrard, I had the same issue for a long time, but on a WAGO webvisu. Now I'm glad that I can share my solution. I don't know if you are trying to use the webvisu or the target visu, but this works on webvisu: Get "go2rtc" and set it up according to the documentation. I'm running the Windows binary. Here's my example of the go2rtc.yaml config file (contains working example streams): api: listen: ":1984" # default ":1984", HTTP API port ("" - disabled) origin: "*" # default "", allow CORS requests (only * supported) static_dir: "www" # default "", folder for static files (custom web interface) tls_listen: ":443" # default "", enable HTTPS server tls_cert: "./SSL/fullchain.pem" tls_key: "./SSL/privatekey.pem" streams: # Streams with multiple links will fall back on the next link. ABUS TVIP48511: - rtsp://<username>:<password>@<hostname>:<port>/ch1/main - rtsp://<username>:<password>@<hostname>:<port>/ch1/sub # Diagnostic connections Kirchhoff Institute for Physics - Germany: http://pendelcam.kip.uni-heidelberg.de/mjpg/video.mjpg Blanton Bottling, Kentucky - USA: http://camera.buffalotrace.com/mjpg/video.mjpg Tokyo - Japan: http://61.211.241.239/nphMotionJpeg?Resolution=320x240&Quality=Standard Tampere Hacklab - Finland: http://tamperehacklab.tunk.org:38001/nphMotionJpeg?Resolution=640x480&Quality=Clarity Soltorget Pajala - Sweden: http://195.196.36.242/mjpg/video.mjpg Kaiskuru Skistadion - Norway: http://77.222.181.11:8080/mjpg/video.mjpg webrtc: listen: ":8555" #ice_servers: # - urls: [ "stun:localhost:3478" ] # username: "" # credential: "" Access the webinterface of go2rtc and get the link of your stream. Use the link as for your browser frame in the visualization. Depending on your device, you need to be able to access the file /etc/lighttpd/lighttpd.conf or /etc/lighttpd/webvisu.conf and change the contents similar to this one, otherwise you'll get CORS and CSP errors in the browser and you won't be able to view the stream on the webvisu: # Webvisu specific settings $SERVER["socket"] =~ port_webvisu_used_any { url.redirect += ( "^/webvisu/?$" => "/webvisu/webvisu.htm" ) $HTTP["url"] =~ "^/webvisu/?" { var.response_header_policy_webvisu = ( # CSP for WebVisu, allowing inline sources. "Content-Security-Policy" => "default-src 'self' 'unsafe-inline'; media-src *; frame-src *", # CORS for WebVisu, allowing any origin to access. "Access-Control-Allow-Origin" => "*", # Tell older browsers that this page can only be displayed if all ancestor # frames are same origin to the page itself. "X-Frame-Options" => "SAMEORIGIN" ) # Response header policy for WebVisu setenv.set-response-header = var.response_header_policy_webvisu setenv.set-response-header += var.response_header_policy_common }
Last updated: 2023-11-14

Post by mubeta on Some 'pathetic' errors in SoftMotion program CODESYS Forge talk (Post)
Hello everyone, I have a very simple program for the process, but it's driving me crazy and I can't see the problems I'm left with: Short topological description: Dual Core Berghof controller with softmotion runtime version 3.5.19.30; Two axes with servodrive on canopen bus, clocked distributed from master; Ethercat I/O node; 2 ms ethercat task, 2 ms canopen bus cycle time; I/O objects of the canopen master and canopen drives connected to the ethercat task cycle; Problem 1: Two separate programs each manage their own axis and drive, with separate state machines. A first axis moves primarily in velocity, except having to position itself absolutely at a predetermined point at the end of the job; the second axis, on the other hand, is a paper unwinder that changes, for each job cycle, from actions in absolute, relative, and cam displacement with the master axis. Well, the state machine of both axes was written in such a way as to call running the useful FB and change it on state change in this way: CASE i_stateMachine OF 0: o_Power(Enable := TRUE, bRegulatorOn := FALSE, bDriveStart := FALSE, Axis := o_PaperUnwinderAxis); o_MoveAbs(Execute := FALSE, Axis := o_PaperUnwinderAxis); o_MoveRel(Execute := FALSE, Axis := o_PaperUnwinderAxis); o_CamSelect(Execute := FALSE, Master := o_MachineAxis, Slave := o_PaperUnwinderAxis, CamTable := cam_PaperUnwinder); o_CamIn(Execute := FALSE, Master := MachineEncoder, Slave := o_PaperUnwinderAxis); o_CamOut(Execute := FALSE, Slave := o_PaperUnwinderAxis); o_SetPosition(Execute := FALSE, Axis := o_PaperUnwinderAxis); IF ... THEN i_StateMachine := 10; END_IF; 10: o_Power( Enable := TRUE, bRegulatorOn := TRUE, bDriveStart := TRUE, Axis := o_PaperUnwinderAxis ); IF o_Power.Status THEN i_StateMachine := 20; END_IF; 20: (* Avanzamento carta *) o_MoveAbs( Execute := TRUE, Position := o_Somewhere, Velocity := 25.0, Acceleration := 3666.7, Deceleration := 3666.7, Jerk := 48000.0, Direction := MC_DIRECTION.positive, Axis := o_PaperUnwinderAxis ); IF o_MoveAbs.Done THEN o_MoveAbs(Execute := FALSE, Axis := o_PaperUnwinderAxis); i_StateMachine := 30; END_IF 30: d_HomingPosition := ...; o_SetPosition( Execute := TRUE, Position := d_HomingPosition, Mode := FALSE, Axis := o_PaperUnwinderAxis ); (* ... *) IF o_SetPosition.Done = TRUE THEN o_SetPosition(Execute := FALSE, Axis := o_PaperUnwinderAxis ); o_LogServer.Append(sMessage := '...', lscClass := LOGSERVER_CLASS.ALWAYS, sdt := o_CommonsMgrData.systime.sdtLocal); i_StateMachine := 40; END_IF; 50: ... The code above is a sketchy example of what I wanted to write. But it gives me a spot problem: in some, the state change results in a drive error, which is unrecoverable except with a reinitialization via SM3_ReinitDrive(). Things are improved a little if in the program I always run the call of all softmotion blocks in this way: o_Power(Axis := o_PaperUnwinderAxis); o_Jog(Axis := o_PaperUnwinderAxis); o_Halt(Axis := o_PaperUnwinderAxis); o_MoveAbs(Axis := o_PaperUnwinderAxis); o_MoveRel(Axis := o_PaperUnwinderAxis); o_CamIn(Master := MachineEncoder, Slave := o_PaperUnwinderAxis); o_CamOut(Slave := o_PaperUnwinderAxis); If I don't execute all the calls of all the motion FBs used, when exchanging machine state often (but not always), the axis goes into error with event id THE_FB_WASNT_CALL... Done a little diagnostics it seems that the FBs return the bDone, before they are completely terminated. I tried doing the machine state exchange not with the bDone bit of the FBs, but with the 'standstill' state of the axis. It didn't seem to change anything. Problem 2: During the use SM3_ReinitDrive() I get the erro in the log: "NetID 0: SDO read error for object 16#607C..." Assuming that the device involved it's one of the two servodrive, (no others device are present in the network), I don't found any object 0x607C in the 'possible object list in/out' of the two drive, and I don't understand where this object can be listed. So any ideas and suggestions regarding these two issues will be very, very welcome. If you need the source project, I am willing to send it.
Last updated: 2024-07-17

Post by smeitink on Timeout Error in Modbus Communication with WAGO PFC200 and iEM2050 Meter using 750-652 Module CODESYS Forge talk (Post)
Hi all, I'm looking for help with an issue I've come across while trying to facilitate Modbus communication between a WAGO PFC200 PLC using a 750-652 communication module and an iEM2050 Series Single Phase Energy Meter. I believe to have everything wired and setup correcty, but I keep running into a "Error time out" message, and by now I don't really know what else to try. My setup is as follows: A PFC200 Wago PLC, which has 2 750-652 Serial Interfaces extension modules connected to its field bus. I'm using one of these to talk to a Schneider iEM2050 - kWh-meter over modbus. I have connected terminal 23 (A) of the iEM2050 to connector 6 (A) on the 750-652. I have connected terminal 24 (B) of the iEM2050 to connector 2 (B) of the 750-652. I'm using 200mm of twisted together wires to connected them both, and I have placed a 120 ohm resistor between A and B at both ends. I've attached relevant pinout images to this post. I then wrote a simple program that configures the Mobus port, as per the datasheet of the iEM2050. You can find an image of the relavent page attached to this post too. This is my program: PROGRAM PLC_PRG VAR Master: FbMbMasterSerial; xIsConnected: BOOL; xError: BOOL; iIndex: INT := 1; xTrigger: BOOL; utQuery : typMbQuery := ( bUnitId := 1, // The Modbus unit or slave address bFunctionCode := 4, // Function code for reading input registers uiReadAddress := 1829, // adress for the Power on off counter uiReadQuantity := 1 // Quantity of registers to read ); iStep: INT; oStatusModbus: WagoSysErrorBase.FbResult; utResponseModbus: typMbResponse; xConnect: BOOL := FALSE; delayTimer: TON; END_VAR Master( xConnect:= xConnect, I_Port:= _750_652_24_1, udiBaudrate:= 9600, usiDataBits:= 8, eParity:= WagoTypesCom.eTTYParity.Even, eStopBits:= WagoTypesCom.eTTYStopBits.One, eHandshake:= WagoTypesCom.eTTYHandshake.None, ePhysical:= WagoTypesCom.eTTYPhysicalLayer.RS485_HalfDuplex, xIsConnected=> xIsConnected, xError=> xError, oStatus=> oStatusModbus, eFrameType:= WagoAppPlcModbus.eMbFrameType.RTU, tTimeOut:= T#5S, utQuery:= utQuery, xTrigger:= xTrigger, utResponse:= utResponseModbus); delayTimer(IN := TRUE, PT := T#3S); // Use the Q output of the timer to set xConnect after the delay IF delayTimer.Q THEN xConnect := TRUE; END_IF CASE iStep OF 0: //Wacht totdat de master de poort geopend heeft IF xIsConnected THEN iStep := 1; END_IF 1: //Stuur request naar de slave xTrigger := TRUE; iStep := 2; 2: //Wacht totdat de master klaar is met het afhandelen van de request IF NOT xTrigger THEN iStep := 3; END_IF END_CASE The TON delay before opening the port is due to a an error I encountered when opening it straight away. This seems to be a bug, as described here. However, the TON solved that particular issue. I tried reading multiple registers, but like I said, I still always end up with the "Error time out". What else can I test or try at this point?
Last updated: 2024-02-24

Post by youness on No source code available (cip object) CODESYS Forge talk (Post)
Hi yotaro, hope your problem was resolved. I had the same, but with an other library title. This exception is not detected during compilation, but rather at a given position in the program (when switching to a given visualization). Although the exception is generated at this point, it does not involve the visualization in question. This error is due to one of 3 reasons: 1) A division by zero somewhere: The program is able to detect divisions by zero at compile time. But in the case of a variable, which takes a valid value at init and changes to 0 at a later stage. 2) An invalid pointer: (either because it has a value of 0, or because it points outside the memory reserved for the program) is being dereferenced. Locate any pointers or interfaces you have in the code and check them - you should also be wary of mixing inline modifications and pointers. 3) Array overflow: Generally when a processing operation is executed outside the array's definition range. Example: a write loop with n iterations is executed on an array of dimmension n-1. On the other hand, the error message may not appear. In the latter case, the error may have fatal consequences, as the overflow has induced writing to potentially forbidden memory areas. This problem can be explained by the fact that it's not always the adjacent memory areas of PLC_PRG that are overwritten, but the memory areas that are randomly allocated to the array during compilation. In this case, however, there is no entry in the log, so you need to integrate the "Implicit Check function", which checks the line of code generating the error. To integrate this functions, click on Application --> POU for implicit controls Regards,
Last updated: 2024-07-16

Post by tk096 on Some 'pathetic' errors in SoftMotion program CODESYS Forge talk (Post)
Meanwhile, I would like to understand why the motion FB instances must still be called even after the Execute is set to FALSE, especially in view of the fact that the next instruction is programmed to abort the previous one, with BufferMode set to 'Aborting'. All these unnecessary FB calls are an unnecessary overhead on the CPU anyway. Is there any precise rule about when to cease calling the various instances? (It should precisely be the 'done' status that says this one has finished its work). In general: - Motion function blocks have to be called until they report 'Done', 'Error', 'CommandAborted' or a subsequent motion FB with BufferMode=Aborting is started in the current cycle. - Setting the Execute input to FALSE will not abort any ongoing motion of the motion function block. For example, one case that is often problematic is the execution of the Axis Halt instruction. When, after a MoveAbosulte instruction this returns the event as 'done' and indeed the axis is in standstill, the state machine first sets the move instruction to FALSE, and the next cycle sets the Halt request to TRUE. Some of the time everything works out fine. Occasionally, however, in this exchange, the axis goes into fault, also losing the OPERATIONAL state. I think the error SMC_FB_WASNT_CALLED_DURING_MOTION is only a follow-up (and misleading) error that results from the axis not being in operational state anymore (bus problems). Is there an error 'regulator or start not set' in the device log before the error 'motion generating FB wasn't called for at least one cycle'? Which error does the respective function block (Halt.ErrorId) report?
Last updated: 2024-07-22

Post by s1ack on Wago PFC200 Ethernet / IoDrvEthernet Issue? CODESYS Forge talk (Post)
CODESYS Control for PFC200 4.13.00 CODESYS IIoT Libraries SL 1.11.0.0 Application Based License: CODESYS Control Standard M I have (2) projects with similar code base and both using Wago PFC200. On the second project I am seeing 2 things that I have not been able to resolve: 1) Errors in the log under the Ethernet Item: IoDrvEthernet: [PCI\E1Q51CE62] Could not be found on target! Please check the Ethernet settings. 2) Exception for CPU Load. "Processorload watchdog: plcload=100, maxplcload=95" I have slowed down cyclic tasks on this project, even though on the first project there is actually more code - and it does not exhibit this behavior. In looking at the CPU loading via Linux 'TOP' command there appears to be 20% idle. So plenty of headroom (my opinion). In an effort to troubleshoot I have duplicated the target hardware on my bench. It ran overnight without a CPU load exception. On the test system, I have tried (3) version of the ethernet device. 3.5.16.0 3.5.17.0 and 4.2.0.0 Presently the log does not show the error, but status says the module reports an error. I really do not know if this issue is related to the CPU load exception. The issue does not appear to effect ethernet communications (ModbusTCP or SNMP or Webvisu or PuTTy into Linux Shell). On my test bench I have ModbusTCP slave simulators for all ModbusTCP slaves, but only (1) of the (5) SNMP devices present.
Last updated: 2025-01-21

Post by rajatdas2005 on Codesys Virtual control SL CODESYS Forge talk (Post)
Dear All, This is regarding Codesys Virtual control SL demo version. I am facing one issue. First I will describe the steps what I have followed till now. 1. In a PC I have Windows OS. Here Codesys IDE is installed, and also using the installer option of IDE I have also installed Codesys Virtual control SL. 2. A edge-gateway is also running in the same windows PC as local host. 3. Next I have a seperate PC with Ubuntu OS with docker installed. This machine is in the same network. 4. Now I have created a project in Windows machine using device "Codesys Virtual control SL". 5. In the Ubuntu machine I am running the Codesys Virtual control SL as docker and it is using the ubuntu machine network only. 6. Next using the localhost edge-gateway when I am searching the virtual control SL docker it is able to detect it. (screenshot attached) 7. But after creating the creadentials it is telling No Device is responding. 8. I have also checked the wireshark logs and able to see that in destination port 11740 data is coming. 9. From windows PC telnet ip 11740 is also working. 10. Ping is also working ===========================================LOGS ========================= sudo ss -tlnp | grep -E "(443|1217|4840|8080|11740)" LISTEN 0 10 10.135.114.142:4840 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=21)) LISTEN 0 10 172.18.0.1:4840 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=24)) LISTEN 0 10 172.17.0.1:4840 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=23)) LISTEN 0 10 127.0.0.1:4840 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=26)) LISTEN 0 10 192.168.122.1:4840 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=22)) LISTEN 0 5 0.0.0.0:11740 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=20)) LISTEN 0 128 0.0.0.0:8080 0.0.0.0: users:(("python3",pid=1280,fd=4)) LISTEN 0 10 172.19.0.1:4840 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=25))
Last updated: 2025-08-06

Post by serwis on Dynamic target position tracking CODESYS Forge talk (Post)
Hello, I am trying to control a servo drive and dynamically set its position. I control the drive via EtherCAT with a cycle time of 500us. I use the MC_MoveAbsolute block for this. The problem is that when using a PID controller, I generate the positions I want the drive to move to on an ongoing basis, and I would like the position to be set immediately. The MC_MoveAbsolute block must receive a rising edge to execute, and I would like the movement to be performed without waiting for this edge. I have created a function that generates a rising edge every 1 ms, but I am unable to change this time to 500 µs because the TON function does not support times shorter than 1 ms. Below is the code to call the rising edge: IF Exe = TRUE THEN delay1(IN:=TRUE, PT:=T#1MS); IF delay1.Q = TRUE THEN Exe := FALSE; delay1(IN:=FALSE); END_IF END_IF IF Exe = FALSE THEN delay(IN:=TRUE, PT:=T#1MS); IF delay.Q = TRUE THEN Exe := TRUE; delay(IN:=FALSE); END_IF END_IF END_IF Here is the code for calling the MC_MoveAbsolute function: MoveDegree( Axis:= Tilt, Execute:= Exe, Position:= position_target - (base_angle_real * feedforward_turn), Velocity:= vel, Acceleration:= acc, Deceleration:= dec, Jerk:= jerk, Direction:= MC_DIRECTION.shortest, BufferMode:= MC_BUFFER_MODE.Aborting, Done=> , Busy=> , Active=> , CommandAborted=> , Error=> , ErrorID=> ); I realize that there are probably better methods for performing this type of task. How can I implement motion with a dynamically changing setpoint? THANKS
Last updated: 2025-09-05

Post by micik on Using Codesys example problems CODESYS Forge talk (Post)
Hello to all, I'm totally new to Codesys, but I do have some PLC programming experience, mosty with Siemens TIA and STEP7. I have just installed Codesys 3.5. sp19 and I have downloaded example with Ethernet Rockwell 1734AENT. The example can be found here: https://forge.codesys.com/prj/codesys-example/rockwell-1734-c/home/Home/ After opening, I had to manually update devices (Device, Ethernet, IP Scanner, EthernetIP adapter). However, when trying to build the project, I get the following errors: [WARNING] CODESYS_EtherNetIP_Rockwell1734AENT: Library Manager [Device: PLC Logic: Application]: C0100: Library System_VisuElemXYChart has not been added to the Library Manager, or no valid license could be found [WARNING] CODESYS_EtherNetIP_Rockwell1734AENT: Library Manager [Device: PLC Logic: Application]: C0100: Library system_visuinputs has not been added to the Library Manager, or no valid license could be found [ERROR] iodrvethernetip, 4.4.1.0 (3s - smart software solutions gmbh): ServiceCycle [IoDrvEtherNetIP]: C0040: Function 'ProcessUpdateConfigurationQueue' requires exactly '1' inputs [ERROR] iodrvethernetip, 4.4.1.0 (3s - smart software solutions gmbh): IoDrvStartBusCycle [IoDrvEtherNetIP]: C0040: Function 'GenerateRandomUINT' requires exactly '2' inputs [ERROR] iodrvethernetip, 4.4.1.0 (3s - smart software solutions gmbh): Cyclic [GenericServiceUnConnected]: C0040: Function 'GenerateRandomUINT' requires exactly '2' inputs [ERROR] cip object, 4.4.1.0 (3s - smart software solutions gmbh): ForwardOpenService [ConnectionManager]: C0040: Function 'GetAssemblies' requires exactly '3' inputs [ERROR] iodrvethernetipadapter, 4.4.0.0 (3s - smart software solutions gmbh): ServiceCycle [IoDrvEtherNetIPAdapter]: C0040: Function 'GenerateRandomUINT' requires exactly '2' inputs [ERROR] iodrvethernetip, 4.4.1.0 (3s - smart software solutions gmbh): SetupStructuredIOMapping [RemoteAdapter]: C0040: Function 'MallocData' requires exactly '1' inputs [ERROR] iodrvethernetip, 4.4.1.0 (3s - smart software solutions gmbh): SetupStructuredIOMapping [RemoteAdapter]: C0040: Function 'MallocData' requires exactly '1' inputs Compile complete -- 7 errors, 13 warnings Build complete -- 7 errors, 13 warnings : no download possible! What could be the reason for this errors and how to rectify them? Thank you!
Last updated: 2024-02-01

Post by mondinmr on Why SysPipeWindows is not implemented in RTE? CODESYS Forge talk (Post)
This library would be very useful for IPC communications. Using a UDP socket on localhost is unpredictable, as with slightly loaded machines it does not even guarantee packet delivery locally. Using TCP creates a lot of overhead. Message named pipes would be an excellent solution for Windows RTE. On Linux, since the release of the extension package, there is no issue, as it is sufficient to develop a component. However, although now 90% of our clients understand that Linux runtimes are better in every way compared to Windows RTE, especially from the security aspect (Not in kernel space) and the issues with Windows updates, 10% stubbornly insist (sometimes for trivial commercial reasons) on using Windows. Managing IPC with circular buffers in shared memory is quite ugly, or rather really ugly and unaesthetic. In the manuals, I saw the SysPipeWindows libraries, so I decided to test them, but unfortunately, I noticed that they are not implemented for RTE devices. Technically, I could try to open them as regular files, but SysFileOpen returns 16#27 or 16#39 depending on how I set the name (direction of the slashes). Here is the code to create shared memory and named pipes. Shared memory work great, named pipes no! #ifdef Q_OS_WIN32 SECURITY_ATTRIBUTES sa; SECURITY_DESCRIPTOR sd; InitializeSecurityDescriptor(&sd, SECURITY_DESCRIPTOR_REVISION); SetSecurityDescriptorDacl(&sd, TRUE, NULL, FALSE); sa.nLength = sizeof(SECURITY_ATTRIBUTES); sa.lpSecurityDescriptor = &sd; sa.bInheritHandle = FALSE; const wchar_t* name = L"Global\\ShmTest"; HANDLE hMapFile = CreateFileMapping( INVALID_HANDLE_VALUE, NULL, PAGE_READWRITE, 0, sizeof(SharedData), name); if (hMapFile == NULL) { qCritical("Error creating shared memory"); return 1; } data = static_cast<SharedData*>(MapViewOfFile(hMapFile, FILE_MAP_ALL_ACCESS, 0, 0, sizeof(SharedData))); if (data == NULL) { qCritical("Error mapping shared memory"); return 1; } HANDLE hPipe = CreateNamedPipe( TEXT("\\\\.\\pipe\\MyPipe"), PIPE_ACCESS_DUPLEX, PIPE_TYPE_MESSAGE | PIPE_READMODE_MESSAGE | PIPE_WAIT, PIPE_UNLIMITED_INSTANCES, 1024 * 1024, 1024 * 1024, NMPWAIT_USE_DEFAULT_WAIT, &sa); if (hPipe == INVALID_HANDLE_VALUE) { qCritical("Error creating named pipe"); return -1; } if (!ConnectNamedPipe(hPipe, NULL)) { qCritical("Error connecting to named pipe"); return -1; } checkPipe(hPipe); #endif
Last updated: 2024-02-02

<< < 1 .. 131 132 133 134 135 .. 152 > >> (Page 133 of 152)

Showing results of 3782

Sort by relevance or date