Search talk: check object is null

 
<< < 1 .. 13 14 15 16 17 .. 128 > >> (Page 15 of 128)

Post by eschwellinger on Scara3 kinematic robot error CODESYS Forge talk (Post)
Please check the jitter in the online taskmonitoring. cylce time of the motion task and jitter in case of the error.
Last updated: 17 hours ago

Post by climblinne on Calling OPC UA Methods from UaExpert CODESYS Forge talk (Post)
Hello, I hope someone could help me. I installed the newest Codesys 3.5 SP 20 Patch 1. When loading the demo files from @i-campbell I can upgrade them to the latest version and everthing works on the OPC-UA client side as expected (object "a" is visible, I can use the "ExampleMethod"). Now I * remove the "Information Model", * delete the "OPC_UA_Symbols Objects", * Add "Information Model" again * add "TestRootObjectType" again and "Generate IEC declarations" * and search for mapped instances (to get instance "a" again) Very good still working as expected. Now I delete the OPC_UA_Symbols and add it again referring to the "objecttest" from 16.9.2020. Also I redo the steps from above. The result is now, that I can't see the "a" object in the "Root/Objects" folder. Why ist this and how can I make it running? I think, it could may be a different version of the UA configuration file. I tried to build my own model definition files and got the same problem (but I am really not an expert). When someone has a actual model, which is also running in the actual Codesys I would be very grateful. Or even better, how to make the correct model in e.g. UA Modeler SW (I followed the description https://documentation.unified-automation.com/uamodeler/1.6.0/html/howprojnet_sec.html).
Last updated: 2024-07-01

Post by hemuv on Dialog Open CODESYS Forge talk (Post)
I'm programming an HMI for a machine. I want to log all the parameter's changes (used text field for displaying and changing) for particular User levels. Created a Numpad and want to log oldvalue and Newvalue on 'ok' Button press. To retrieve the oldvalue, i check if the dialogue opened is my Numpad, Then I retrieve the dialogue interface via GetDialogInterface(ADR(myNumpad)) --> numpadData.stVariableValue which contain my oldvalue and save it locally. Problem is sometimes i retrieve the data and sometimes not. Also observed when Numpad Dialogue is Opened, VisuDlgUtil_IsDialogOpen returns False in some cycles.Attached you will find my Project. please let me know what went wrong or if there is a better approach to collect old and New Value of a textfield. Thank you.
Last updated: 2025-03-26

Post by fmon on Modbus : dis- / re-connect cable: modbus does not re-start CODESYS Forge talk (Post)
Hello, I am using codesys Modbus TCP client (4.4.0.0) to communicate with a python modbus server (package pyModbusTCP). I first start my python server on the distant machine. After a fresh codesys compilation, a plc connection/transfer and a PLC run, the modbus connection is OK. Every time in this context the connection is created correctly. When I shut down the server, the modbus connection falls, that is normal. When I restart the python server, impossible to recreate the modbus connexion. With the client autoreconnection, I see on my server that the client tries to connect but unsuccesfully. I have the following message : DEBUG:pyModbusTCP.server:accept new connection from ClientInfo(address='192.168.1.20', port=33476) DEBUG:pyModbusTCP.server:Exception during request handling: NetworkError('recv return null') I tried to stop the codesys client and to restart it with these commands : Modbus_TCP_Client.xStop := True; // Or False Modbus_TCP_Client.Enable := True; // Or False Modbus_TCP_Server.Enable := True; // Or False I tried to confirm the error manually to force reconnection with: Modbus_TCP_Server_Motors.xConfirmError := TRUE; I tried also this command to STOP/RESET/START client and server (codesys side) but nothing happens : status_client := Modbus_TCP_Client.SetCommunicationState(eRequestedState := DED.DEVICE_TRANSITION_STATE.STOP); // .RESET & .START The answer of this function when executed is "status_client = NOT_SUPPORTED" It seems that is a socket problem, but I do not understand if it is on the client or server side. I tried a modbus simulator called "ananas.exe" and the result is the same. Impossible to get a modbus reconnection. What is different at the first connection and at a reconnection attempt ? Thanks for your help
Last updated: 2025-03-14

Post by callumo1 on Check For Open Dialogs On Client CODESYS Forge talk (Post)
Thanks for the reply. I want to be able to check if any dialogs are open of any name. I already have a function similar to what you have send but I don't want to have to run it for all the different dialog names. Thanks
Last updated: 2023-09-26

Post by marekxc on Compiling Errors with Ethernet/IP Scanner CODESYS Forge talk (Post)
Update the Device: Right-click on the device icon in the project tree. Select the β€œUpdate Device” option. Recompile the Project: After updating the device, recompile the project from scratch to ensure that all changes are included. Check Task Settings: Go to the β€œTasks” tab in the project. Check the priority settings for the tasks to ensure they are configured correctly.
Last updated: 2024-11-09

Post by pernockham on Gateway in China - "Gateway not connected" CODESYS Forge talk (Post)
Gateway and runtime (Control for linux SL) on a debian linux. Thanks for your check. Good to know. I will probably travel there in about a months time so that will give me better possibility for further testing. (on a side note, I dont get mail-updates on forum-subscriptions, need to check the topics manually)
Last updated: 2025-09-26

Post by thisischris on "You are using inconsistent overlay settings, please check your compiler defines for the current application" error CODESYS Forge talk (Post)
Hello. I am a new user. On generating the first test project I am receiving this error message. You are using inconsistent overlay settings, please check your compilerdefines for the current application (-> GENERATE_OVERLAY_VISU) and the setting within the visualization manager. Can anyone help?
Last updated: 2024-05-28

Post by song on How to convert a standard robot program into an excutive list when a robot runs? CODESYS Forge talk (Post)
Dear Sir, I'd like to learn and try to make robot based on Codesys, is there a FB block or other ways to convert a standard robot program into an excutive list? how codesys explain the robot command instructions on HMI, just like the SMC_NCDecoder used to convert CNC program into a list of SMC_GEOINFO object. Thanks very much! Peter Yan
Last updated: 2023-11-25

Post by jzhvymetal77 on Special Chars in Visualizationfor QR code string CODESYS Forge talk (Post)
In Visualization, is there any way to make special characters in a string display properly in a Text object? I wrote a function block to create QR codes at runtime. My code uses β€œ$DB,” which in ASCII should render as a solid block. The code works, but to display it in Visualization I had to create multiple rectangles with visibility bound to a BOOL array. That works, but since each BOOL must be exposed as a separate variable, it consumes most of the available monitoring resources. See Attached image.
Last updated: 2025-09-29

Post by jzhvymetal77 on Special Chars in Visualizationfor QR code string CODESYS Forge talk (Post)
In Visualization, is there any way to make special characters in a string display properly in a Text object? I wrote a function block to create QR codes at runtime. My code uses β€œ$DB,” which in ASCII should render as a solid block. The code works, but to display it in Visualization I had to create multiple rectangles with visibility bound to a BOOL array. That works, but since each BOOL must be exposed as a separate variable, it consumes most of the available monitoring resources. See Attached image.
Last updated: 2025-09-29

Post by otdeveloper on IEC 61499 CODESYS Forge talk (Post)
It is being worked on by many companies and its even-driven function blocks seem like a natural evolution of the object oriented industrial programming I have seen Gary Pratt (author of the Book of CODESYS and much more) so expertly implement and explain. I would expect CODESYS to have this front and center on their sights and, if they do not, I would be very interested in learning why.
Last updated: 2024-02-09

When Keyboard Key is in Hold, then Webvisu is extreme slow and latent CODESYS Forge talk (Thread)
When Keyboard Key is in Hold, then Webvisu is extreme slow and latent
Last updated: 2023-09-20

download project via codesys is slow but tftp/ftp/iperf is fast ?? CODESYS Forge talk (Thread)
download project via codesys is slow but tftp/ftp/iperf is fast ??
Last updated: 2025-09-20

download project via codesys is slow but tftp/ftp/iperf is fast ?? CODESYS Forge talk (Thread)
download project via codesys is slow but tftp/ftp/iperf is fast ??
Last updated: 2025-09-20

When Keyboard Key is in Hold, then Webvisu is extreme slow and latent CODESYS Forge talk (Thread)
When Keyboard Key is in Hold, then Webvisu is extreme slow and latent
Last updated: 2023-01-17

Pragma code is not getting compiled... is this normal? can it be changed somehow? CODESYS Forge talk (Thread)
Pragma code is not getting compiled... is this normal? can it be changed somehow?
Last updated: 2016-06-03

Is using Codesys 3.5 SP8 for Beckhoff PLC is do able? CODESYS Forge talk (Thread)
Is using Codesys 3.5 SP8 for Beckhoff PLC is do able?
Last updated: 2016-01-08

GPIO After the sample project is booted, DI works normally but DO is not output. CODESYS Forge talk (Thread)
GPIO After the sample project is booted, DI works normally but DO is not output.
Last updated: 2017-03-27

Post by stribor on Passing properties as VAR_IN_OUT variables. CODESYS Forge talk (Post)
I am designing a custom slider object and i ran into a problem when i want to use properties with it. I can update the basic variables if i have a slider variable defined as VAR_IN_OUT, but it does not work with properties. How can i achieve same functionality that some basic objects have (for example basic Slider that comes withing the codesys libraries) such that i can pass both variables and properties to it and they can be modified within the object? I am using Codesys V3.5 SP20 Patch 5.
Last updated: 2025-03-01

Post by yannick on Raspberry PI 5 not working CODESYS Forge talk (Post)
Hello I'm using Codesys V3.5 SP19 Patch 6 and a Raspberry PI 5 4GB Bookworm 32bit with the Runtime 4.11.0.0 SL. I can install the runtime and download the software completly but after a few seconds the connection disconnects with the message no connection to device. Please scan network again. And the object reference was not set to an object instance. See screenshot. Can somebody help me with that? Thanks
Last updated: 2024-04-28

Access Violation when breakpoint is hit CODESYS Forge talk (Thread)
Access Violation when breakpoint is hit
Last updated: 2023-06-30

Online view : code is scanned CODESYS Forge talk (Thread)
Online view : code is scanned
Last updated: 2023-10-23

RPI is license server down CODESYS Forge talk (Thread)
RPI is license server down
Last updated: 2023-10-30

What is the insights of IoDrvEtherCAT.DCInSyncWindow? CODESYS Forge talk (Thread)
What is the insights of IoDrvEtherCAT.DCInSyncWindow?
Last updated: 2024-07-09

<< < 1 .. 13 14 15 16 17 .. 128 > >> (Page 15 of 128)

Showing results of 3197

Sort by relevance or date