Search talk: setting value of variable

 
<< < 1 .. 142 143 144 145 146 .. 149 > >> (Page 144 of 149)

Post by clesio on CAA.File.Write – Unexpected characters when writing a CSV file CODESYS Forge talk (Post)
Hello everyone, I am trying to create a routine in CODESYS to export a report to a CSV file using the CAA.File library. The file is created successfully, but I am getting some unexpected/unknown characters in the generated CSV. The problem seems to be related to the SIZEOF() function. I am using it for the szSize parameter of File.Write, as recommended in the CODESYS documentation. However, when I use SIZEOF(), the CSV contains extra characters and parts of previous strings. I also tried using LEN(), but in my application the file is created empty, even though the string and the calculated length appear to be correct. Here is the relevant part of my code: PROGRAM Relatorio VAR // Bool b_Executa_fb_Cria_Arquivo : BOOL; b_Executa_fb_Fecha_Arquivo : BOOL; b_Escreve_dados : BOOL; b_Erro_fb_Escreve : BOOL; //STR s_Nome_Arquivo : STRING; s_Palavra : STRING; s_Palavra_Anterior : STRING; s_Data_Atualizada_Formatada : STRING; s_Dia : STRING; s_Mes : STRING; s_Ano : STRING; s_Hora_Atualizada_Formatada : STRING; s_Hora : STRING; s_Minu : STRING; s_Segu : STRING; //INT i_modo_fb_Cria_Arquivo : INT; i_ErroID_fb_Escreve : INT; //UINT i_Tamanho_Palavra : UINT; // Blocos de Funcao fb_Cria_Arquivo : FILE.Open; fb_Fecha_Arquivo : FILE.Close; fb_Escreve : FILE.Write; // DATA E HORA sc_DataTime : SysTimeRtc.RTS_SYSTIMEDATE; // STRUCT = sc uidResultRtcGet : UDINT; //stGetDate : SysTimeRtc.RTS_SYSTIMEDATE; uidResultConvertToDate : UDINT; uidResult : RTS_IEC_RESULT; END_VAR VAR_INPUT //BOOL b_SET_Executa_fb_Cria_Arquivo : BOOL; b_RES_Executa_fb_Cria_Arquivo : BOOL; b_Executa_fb_Escrita : BOOL; // INT i_Linhas_Cabecalho : INT; i_Linhas_Cabecalho_Anterior : INT; END_VAR // Para Testes s_Nome_Arquivo := 'relatorio/Teste1M.CSV'; i_modo_fb_Cria_Arquivo := 0; // TRATAMENTO DE DATOS DATA e HORA uidResultRtcGet := SysTimeRtcGet(uidResult); uidResultConvertToDate := SysTimeRtcConvertUtcToDate(dwTimestampUtc := uidResultRtcGet, pDate := sc_DataTime); // FORMATA DATA EM UMA STRING s_Dia := UINT_TO_STRING(sc_DataTime.wDay); s_Mes := UINT_TO_STRING(sc_DataTime.wMonth); s_Ano := UINT_TO_STRING(sc_DataTime.wYear); s_Data_Atualizada_Formatada := CONCAT(s_Dia, CONCAT('/', CONCAT(s_Mes, CONCAT('/', s_Ano)))); // FORMATA HORA EM UMA STRING s_Hora := UINT_TO_STRING(sc_DataTime.wHour); s_Minu := UINT_TO_STRING(sc_DataTime.wMinute); s_Segu := UINT_TO_STRING(sc_DataTime.wSecond); s_Hora_Atualizada_Formatada := CONCAT(s_Hora, CONCAT(':', CONCAT(s_Minu, CONCAT(':', s_Segu)))); // ABRE e CRIA ARQUIVO IF (b_SET_Executa_fb_Cria_Arquivo OR b_Executa_fb_Cria_Arquivo) AND NOT(b_RES_Executa_fb_Cria_Arquivo) THEN b_Executa_fb_Cria_Arquivo := TRUE; ELSE b_Executa_fb_Cria_Arquivo := FALSE; END_IF fb_Cria_Arquivo( xExecute := b_Executa_fb_Cria_Arquivo, sFileName := s_Nome_Arquivo, eFileMode := i_modo_fb_Cria_Arquivo, xExclusive := FALSE, ); //i_Tamanho_Palavra := SizeOf(s_Palavra); // ESCREVE NO ARQUIVO fb_Escreve( xExecute := b_Executa_fb_Escrita, hFile := fb_Cria_arquivo.hFile, szSize := SIZEOF(s_Palavra), pBuffer := ADR(s_palavra) ); // FECHA ARQUIVO fb_Fecha_Arquivo( xExecute := b_Executa_fb_Fecha_Arquivo, hFile := fb_Cria_arquivo.hFile ); IF Criacao_Edicao_Arquivos.b_Escreve_Cabecalho THEN CASE i_Linhas_Cabecalho OF 1 : s_palavra := 'ESTERILIZADOR'; 2: s_palavra := 'MAQ4; $R$L'; 3: s_palavra := CONCAT(CONCAT('CLIENTE: ',GVL.sReceitaAtual), '$R$L'); 4: s_palavra := CONCAT(CONCAT('NUMERO LOTE: ',DINT_TO_STRING(GVL.Lote)), '$R$L'); 5: s_palavra := CONCAT(CONCAT('OPERADOR: ', DINT_TO_STRING(GVL.Operador)), '$R$L'); 6: s_palavra := CONCAT(CONCAT('DATA: ', s_Data_Atualizada_Formatada), '$R$L'); 7: s_palavra := CONCAT(CONCAT('HORA: ', s_Hora_Atualizada_Formatada), '$R$L'); 8: s_palavra := '$R$L'; 9: s_palavra := 'PARAMETROS AJUSTADOS $R$L'; 10: s_palavra := CONCAT('TEMPO PRE COND.: ', CONCAT(INT_TO_STRING(GVL.rc_T_PreCondicionamento), ' min $R$L')); 11: s_palavra := CONCAT('PULSOS INERTIZACAO 1: ', CONCAT(INT_TO_STRING(GVL.rc_PulsosInertizacao_1), ' PULSOS $R$L')); 12: s_palavra := CONCAT('PULSOS INERTIZACAO 2: ', CONCAT(INT_TO_STRING(GVL.rc_PulsosInertizacao_2), ' PULSOS $R$L')); 13: s_palavra := CONCAT('PULSOS AERACAO: ', CONCAT(INT_TO_STRING(GVL.rc_PulsosAeracao_2), ' PULSOS $R$L')); 14: s_palavra := CONCAT('PRESSAO DE VACUO 1: ', CONCAT(REAL_TO_STRING(GVL.rc_PV1_max), ' bar $R$L')); 15: s_palavra := CONCAT('PRESSAO DE VACUO 2: ', CONCAT(REAL_TO_STRING(GVL.rc_PV2), ' bar $R$L')); 16: s_palavra := CONCAT('PRESSAO INERTIZACAO 1: ', CONCAT(REAL_TO_STRING(GVL.rc_PN1), ' bar $R$L')); 17: s_palavra := CONCAT('PRESSAO INERTIZACAO 2: ', CONCAT(REAL_TO_STRING(GVL.rc_PN2), ' bar $R$L')); 18: s_palavra := CONCAT('PRESSAO AERACAO: ', CONCAT(REAL_TO_STRING(GVL.rc_PAR), ' bar $R$L')); 19: s_palavra := CONCAT('PRESSAO ETO: ', CONCAT(REAL_TO_STRING(GVL.rc_PressaoETO), ' bar $R$L')); 20: s_palavra := CONCAT('PRESSAO Compl.: ', CONCAT(REAL_TO_STRING(GVL.rc_PressaoETO_2), ' bar $R$L')); 21: s_palavra := CONCAT('MASSA ETO: ', CONCAT(REAL_TO_STRING(GVL.rc_QuantidadeETO), ' Kg $R$L')); 22: s_palavra := CONCAT('TEMPO PRE COND. Vacuo/Vapor: ', CONCAT(INT_TO_STRING(GVL.rc_T_Vapor_1), ' min $R$L')); 23: s_palavra := CONCAT('SET-POINT: ', CONCAT(REAL_TO_STRING(GVL.ihm_SPTemperatura), ' Β°C $R$L')); 24: s_palavra := CONCAT('TEMPO ESTERILIZACAO: ', CONCAT(INT_TO_STRING(GVL.rc_TempoEsterilizacao), ' min $R$L')); 25: s_palavra := CONCAT('TEMPO PARADA: ', CONCAT(INT_TO_STRING(GVL.rc_T_PressaoParada), ' min $R$L')); 26: s_palavra := CONCAT('UMIDADE: ', CONCAT(REAL_TO_STRING(GVL.rc_UmidadeRelativa), ' % $R$L')); 27: s_palavra := '$R$L'; END_CASE END_IF Note: The code I am attaching does not include the execution/sequence management of the function blocks. I have omitted this part to keep the example focused on the CSV writing routine. The function blocks are triggered and managed by a separate state machine. I am not sure what the correct approach is in this case, especially since the official documentation recommends using SIZEOF() for szSize. I will attach my code and a screenshot of the generated CSV showing the issue. Has anyone experienced something similar or could suggest the correct way to write a changing STRING to a CSV file using CAA.File.Write?
Last updated: 2026-09-08

Post by clesio on CAA.File.Write – Unexpected characters when writing a CSV file CODESYS Forge talk (Post)
Hello everyone, I am trying to create a routine in CODESYS to export a report to a CSV file using the CAA.File library. The file is created successfully, but I am getting some unexpected/unknown characters in the generated CSV. The problem seems to be related to the SIZEOF() function. I am using it for the szSize parameter of File.Write, as recommended in the CODESYS documentation. However, when I use SIZEOF(), the CSV contains extra characters and parts of previous strings. I also tried using LEN(), but in my application the file is created empty, even though the string and the calculated length appear to be correct. Here is the relevant part of my code: PROGRAM Relatorio VAR // Bool b_Executa_fb_Cria_Arquivo : BOOL; b_Executa_fb_Fecha_Arquivo : BOOL; b_Escreve_dados : BOOL; b_Erro_fb_Escreve : BOOL; //STR s_Nome_Arquivo : STRING; s_Palavra : STRING; s_Palavra_Anterior : STRING; s_Data_Atualizada_Formatada : STRING; s_Dia : STRING; s_Mes : STRING; s_Ano : STRING; s_Hora_Atualizada_Formatada : STRING; s_Hora : STRING; s_Minu : STRING; s_Segu : STRING; //INT i_modo_fb_Cria_Arquivo : INT; i_ErroID_fb_Escreve : INT; //UINT i_Tamanho_Palavra : UINT; // Blocos de Funcao fb_Cria_Arquivo : FILE.Open; fb_Fecha_Arquivo : FILE.Close; fb_Escreve : FILE.Write; // DATA E HORA sc_DataTime : SysTimeRtc.RTS_SYSTIMEDATE; // STRUCT = sc uidResultRtcGet : UDINT; //stGetDate : SysTimeRtc.RTS_SYSTIMEDATE; uidResultConvertToDate : UDINT; uidResult : RTS_IEC_RESULT; END_VAR VAR_INPUT //BOOL b_SET_Executa_fb_Cria_Arquivo : BOOL; b_RES_Executa_fb_Cria_Arquivo : BOOL; b_Executa_fb_Escrita : BOOL; // INT i_Linhas_Cabecalho : INT; i_Linhas_Cabecalho_Anterior : INT; END_VAR // Para Testes s_Nome_Arquivo := 'relatorio/Teste1M.CSV'; i_modo_fb_Cria_Arquivo := 0; // TRATAMENTO DE DATOS DATA e HORA uidResultRtcGet := SysTimeRtcGet(uidResult); uidResultConvertToDate := SysTimeRtcConvertUtcToDate(dwTimestampUtc := uidResultRtcGet, pDate := sc_DataTime); // FORMATA DATA EM UMA STRING s_Dia := UINT_TO_STRING(sc_DataTime.wDay); s_Mes := UINT_TO_STRING(sc_DataTime.wMonth); s_Ano := UINT_TO_STRING(sc_DataTime.wYear); s_Data_Atualizada_Formatada := CONCAT(s_Dia, CONCAT('/', CONCAT(s_Mes, CONCAT('/', s_Ano)))); // FORMATA HORA EM UMA STRING s_Hora := UINT_TO_STRING(sc_DataTime.wHour); s_Minu := UINT_TO_STRING(sc_DataTime.wMinute); s_Segu := UINT_TO_STRING(sc_DataTime.wSecond); s_Hora_Atualizada_Formatada := CONCAT(s_Hora, CONCAT(':', CONCAT(s_Minu, CONCAT(':', s_Segu)))); // ABRE e CRIA ARQUIVO IF (b_SET_Executa_fb_Cria_Arquivo OR b_Executa_fb_Cria_Arquivo) AND NOT(b_RES_Executa_fb_Cria_Arquivo) THEN b_Executa_fb_Cria_Arquivo := TRUE; ELSE b_Executa_fb_Cria_Arquivo := FALSE; END_IF fb_Cria_Arquivo( xExecute := b_Executa_fb_Cria_Arquivo, sFileName := s_Nome_Arquivo, eFileMode := i_modo_fb_Cria_Arquivo, xExclusive := FALSE, ); //i_Tamanho_Palavra := SizeOf(s_Palavra); // ESCREVE NO ARQUIVO fb_Escreve( xExecute := b_Executa_fb_Escrita, hFile := fb_Cria_arquivo.hFile, szSize := SIZEOF(s_Palavra), pBuffer := ADR(s_palavra) ); // FECHA ARQUIVO fb_Fecha_Arquivo( xExecute := b_Executa_fb_Fecha_Arquivo, hFile := fb_Cria_arquivo.hFile ); IF Criacao_Edicao_Arquivos.b_Escreve_Cabecalho THEN CASE i_Linhas_Cabecalho OF 1 : s_palavra := 'ESTERILIZADOR'; 2: s_palavra := 'MAQ4; $R$L'; 3: s_palavra := CONCAT(CONCAT('CLIENTE: ',GVL.sReceitaAtual), '$R$L'); 4: s_palavra := CONCAT(CONCAT('NUMERO LOTE: ',DINT_TO_STRING(GVL.Lote)), '$R$L'); 5: s_palavra := CONCAT(CONCAT('OPERADOR: ', DINT_TO_STRING(GVL.Operador)), '$R$L'); 6: s_palavra := CONCAT(CONCAT('DATA: ', s_Data_Atualizada_Formatada), '$R$L'); 7: s_palavra := CONCAT(CONCAT('HORA: ', s_Hora_Atualizada_Formatada), '$R$L'); 8: s_palavra := '$R$L'; 9: s_palavra := 'PARAMETROS AJUSTADOS $R$L'; 10: s_palavra := CONCAT('TEMPO PRE COND.: ', CONCAT(INT_TO_STRING(GVL.rc_T_PreCondicionamento), ' min $R$L')); 11: s_palavra := CONCAT('PULSOS INERTIZACAO 1: ', CONCAT(INT_TO_STRING(GVL.rc_PulsosInertizacao_1), ' PULSOS $R$L')); 12: s_palavra := CONCAT('PULSOS INERTIZACAO 2: ', CONCAT(INT_TO_STRING(GVL.rc_PulsosInertizacao_2), ' PULSOS $R$L')); 13: s_palavra := CONCAT('PULSOS AERACAO: ', CONCAT(INT_TO_STRING(GVL.rc_PulsosAeracao_2), ' PULSOS $R$L')); 14: s_palavra := CONCAT('PRESSAO DE VACUO 1: ', CONCAT(REAL_TO_STRING(GVL.rc_PV1_max), ' bar $R$L')); 15: s_palavra := CONCAT('PRESSAO DE VACUO 2: ', CONCAT(REAL_TO_STRING(GVL.rc_PV2), ' bar $R$L')); 16: s_palavra := CONCAT('PRESSAO INERTIZACAO 1: ', CONCAT(REAL_TO_STRING(GVL.rc_PN1), ' bar $R$L')); 17: s_palavra := CONCAT('PRESSAO INERTIZACAO 2: ', CONCAT(REAL_TO_STRING(GVL.rc_PN2), ' bar $R$L')); 18: s_palavra := CONCAT('PRESSAO AERACAO: ', CONCAT(REAL_TO_STRING(GVL.rc_PAR), ' bar $R$L')); 19: s_palavra := CONCAT('PRESSAO ETO: ', CONCAT(REAL_TO_STRING(GVL.rc_PressaoETO), ' bar $R$L')); 20: s_palavra := CONCAT('PRESSAO Compl.: ', CONCAT(REAL_TO_STRING(GVL.rc_PressaoETO_2), ' bar $R$L')); 21: s_palavra := CONCAT('MASSA ETO: ', CONCAT(REAL_TO_STRING(GVL.rc_QuantidadeETO), ' Kg $R$L')); 22: s_palavra := CONCAT('TEMPO PRE COND. Vacuo/Vapor: ', CONCAT(INT_TO_STRING(GVL.rc_T_Vapor_1), ' min $R$L')); 23: s_palavra := CONCAT('SET-POINT: ', CONCAT(REAL_TO_STRING(GVL.ihm_SPTemperatura), ' Β°C $R$L')); 24: s_palavra := CONCAT('TEMPO ESTERILIZACAO: ', CONCAT(INT_TO_STRING(GVL.rc_TempoEsterilizacao), ' min $R$L')); 25: s_palavra := CONCAT('TEMPO PARADA: ', CONCAT(INT_TO_STRING(GVL.rc_T_PressaoParada), ' min $R$L')); 26: s_palavra := CONCAT('UMIDADE: ', CONCAT(REAL_TO_STRING(GVL.rc_UmidadeRelativa), ' % $R$L')); 27: s_palavra := '$R$L'; END_CASE END_IF Note: The code I am attaching does not include the execution/sequence management of the function blocks. I have omitted this part to keep the example focused on the CSV writing routine. The function blocks are triggered and managed by a separate state machine. I am not sure what the correct approach is in this case, especially since the official documentation recommends using SIZEOF() for szSize. I will attach my code and a screenshot of the generated CSV showing the issue. Has anyone experienced something similar or could suggest the correct way to write a changing STRING to a CSV file using CAA.File.Write?
Last updated: 2026-09-08

Post by kuegerls on PROFINET Controller SL: WRREC remains BUSY forever, no DCE/RPC packets transmitted (RevPi Connect 5 + NORD SK205E) CODESYS Forge talk (Post)
Hello , I am currently evaluating the CODESYS PROFINET Controller SL on a Revolution Pi Connect 5 and have encountered a problem with acyclic PROFINET Record Access (WRREC/RDREC). System Hardware: Revolution Pi Connect 5 Runtime: CODESYS Control 4.16.0.0 (SDK 3.5.21.10) Development System: CODESYS V3.5 SP21 (64-bit) CommFB: 3.5.17.10 ProfinetCommon: 4.6.0.0 PROFINET Controller Device: PN-Controller 4.6.0.0 PROFINET Device: NORD DRIVESYSTEMS SK205E with SK TU4-PNT GSDML: GSDML-V2.46-NORDDRIVESYSTEMS-PNT-20251016.xml Network The PROFINET network is completely separated from the office network. RevPi: eth0 β†’ Office network eth1 β†’ PROFINET wlan0 β†’ Visualization The PN Controller is configured to use eth1. IP configuration: RevPi (eth1): 192.168.100.1/24 NORD Drive: 192.168.100.3 Connection is established successfully. Current Status The PN Controller reports: Controller Status = Run Online = TRUE IP Active = TRUE Connections = 1 Cyclic PROFINET IO communication works correctly. Problem I am trying to access PKW parameters via WRREC (Record Index 100). The request buffer contains: 01 14 00 04 92 00 00 00 00 00 00 which corresponds to Reference = 0x01 Request = Read Axis = 0 Parameter = 170 + 1000 Subindex = 0 Value = 0 The WRREC call is fbWRREC( REQ := xWrReq, ID := ConnectionID, INDEX := 100, LEN := 11, RECORD := ADR(TxBuffer) ); REQ is pulsed for one PLC cycle only. Observed Behaviour WRREC enters BUSY state and never finishes. Observed values: BUSY = TRUE DONE = FALSE ERROR = FALSE STATUS = 16#FFFFFFFF indefinitely. Packet Capture A Wireshark capture was taken on the PROFINET network. Observed traffic: PROFINET RT LLDP DCP Observed: successful cyclic IO Not observed: DCE/RPC Record Write Record Read RPC Bind No RPC packets are transmitted at all. Diagnostic Messages The controller repeatedly reports AR alarm.ind(err) AR CMI timeout although cyclic IO communication continues to work. Already Verified The following points have already been checked: correct Ethernet interface (eth1) correct CREATE_ID result correct Device ID correct Slot/Subslot correct GSDML correct REQ pulse RECORD buffer is larger than LEN cyclic IO communication works different Record Indices (100...104) tested Question Is there any known issue or limitation where WRREC/RDREC requests remain permanently BUSY and no RPC Record Access packets are generated? Could this behaviour be related to Runtime 4.16.0.0, PN Controller 4.6.0.0, the missing runtime license (currently running in demo mode), or any known issue with the PROFINET Controller SL? I am currently evaluating the PROFINET Controller SL and therefore the runtime is operating in demo mode. Could you please confirm whether WRREC/RDREC (acyclic Record Data services) are fully supported in demo mode, or whether a valid license is required for these services? If required, I can provide: complete project archive Wireshark capture (.pcap) GSDML online screenshots diagnostic log Thank you very much for your help. Best regards, Stefan
Last updated: 2026-07-17

<< < 1 .. 142 143 144 145 146 .. 149 > >> (Page 144 of 149)

Showing results of 3707

Sort by relevance or date