Post by joschi2804 on Licensing info not available.
CODESYS Forge
talk
(Post)
Hi, maybe this fixes your problem. At least this was our issue back then. We tried to run the codesys runtime environment on an embedded Linux system. The problem on our side was that we changed the WORKDIR directory in the /etc/init.d/codesyscontrol script to /home/user/codesys, but we forgot to copy all files (including the hidden files) from the initial WORKDIR (I am not sure but I guess the initial WORKDIR was /var/opt/codesys) to the new one. After copying those files and restarting codemeter and codesyscontrol, we were able to upload licenses. Hope this help BR Josef
Last updated: 2024-07-10
Post by sebastian-hk on Codesys auf einen Cortex M4 lauffähig machen
CODESYS Forge
talk
(Post)
Hallo, wir spielen mit dem Gedanken, Codesys auf einen AT SAM E54 Xplained Pro lauffähig zu machen. dieser besitzt einen Atmel ATSAME54P20A mit einem Cortex M4. Meine Fragen hierbei: Was muss portiert werden, wenn die Zielhardware momentan noch nicht unterstützt wird? Gibt es ggf. Anleitungen, um die Laufzeit auf solch einen Controller zu bringen? Muss hierbei ein eigener Interpreter entwickelt werden, der den compilierten Code "übersetzt"? Wie lauffähig ist der rübergespielte Code, gibt es irgendwelche Einschränkungen bei der Programmierung in Codesys? (Verwendung von bestimmten Datentypen nicht möglich?) Was für Lizenzen werden für den Controller benötigt? Vielen Dank im Voraus Sebastian
Last updated: 2024-01-03
Post by mp9876 on Attempting customizing menus fails in LADDER environment; due to free CODESYS version ?
CODESYS Forge
talk
(Post)
Hello, I am attempting to get started here and bumping into this funny issue. I am using this version of CODESYS: ============================== DETAILED VERSION INFORMATION Created at 2024-03-10 ============================== Startup profile: ............................................................... CODESYS V3.5 SP19 Patch 6 OS version: .................................................................... Microsoft Windows NT 10.0.19045.0 .NET version: .................................................................. 4.0.30319.42000 When attempting to customize the menus or toolbar it does not work. The additional commands, Insert TON box & Insert TOFF box, are present in the Customize Menus or Toolbars when re-opening the Customize options but neither the menu or the toolbar gets updated with these. Would also like to add them in the Ladder Toolbox as there are only 9 items in there which does not include the one mentioned above. Due because of the version I am using ? Any assistance would definitely be appreciated. Thank you Mike
Last updated: 2024-03-10
Post by kevintumibay on Struggling to connect to EK1100 to Raspberry Pi
CODESYS Forge
talk
(Post)
SUMMARIZED VERSION OF QUESTION: I'm trying to connect a Raspberry Pi running "Codesys Control for Raspberry Pi" to a Beckhoff EK1100, unfortunately, when I try to connect I get the following messages SEE FIRST PICTURE DETAILED VERSION OF QUESTION: Hi everyone, I'm a college student that is super interested in learning about PLCs. I wanted to dive into the subject and decided to follow this great Instructables article: https://www.instructables.com/Programming-Raspberry-Pi-With-CODESYS/ Thank you in advance for your help! My current setup is as follows: 1. I have Codesys Control for Raspberry Pi, version 4.14.0.0, (https://store.codesys.com/en/codesys-control-for-raspberry-pi-sl.html) installed on a Raspberry Pi 3B. 2. I am using my smartphone hotspot to create a network. 3. I have CODESYS 3.5 SP21 (64 bit) installed on my Windows 11 laptop. 4. Both the Raspberry Pi and my laptop are connected to the smartphone hotspot network (I am wirelessly connecting to the Raspberry Pi). Connecting to the Raspberry Pi from CODESYS on my laptop: 1. I launch Codesys Installer -> I install Codesys Control for Raspberry Pi (link to the software). 2. I launch Codesys 3.5 SP21 (64 bit) on my laptop. 3. I go to file --> new project --> standard project --> in the pop-up I select "Codesys Control for Raspberry Pi" and "Structured Text" 4. I click on tools -> Deploy Control SL (on older versions of Codesys you would click on "update Raspberry Pi", I got that information from this video: link) 5. Inside Deploy Control SL --> I go to the "communication" menu and I input the IP address of my Pi, the password, and click on connect. 6. Inside Deploy Control SL --> I go to the "deployment" menu and I install Codesys Control for Raspberry Pi SL and Codesys Edge Gateway for Linux 7. Now I double click on "device" in the left hand tree and put in the IP address of my Raspberry Pi and click on connect --> success! I am able to connect! SEE SECOND PICTURE Powering the EK1100 and connecting it to the Raspberry Pi: 1. I am supplying the EK1100 with 24 V across the + and - pins. 2. I have jumper wires going from the + pin to the 24V pin and from the - pin to the 0V pin. SEE THIRD PICTURE 4. I am pretty confident that the EK1100 is receiving power because the "LED Us 24 V" and "LED Up 24 V" are lighting up. 5. I then run an ethernet cable from the EK1100 to the Raspberry Pi port (the Raspberry Pi is connected to my laptop wirelessly over WiFi). I think this connection should also be good since the LINK/ACT LED lights up. Trying to connect to the EK1100: 1. Back in Codesys I right-click on "Device" in the left tree and then in the pop up I click on "add device". 2. I then click on EtherCAT Master. 3. Next in a terminal window I SSH into the raspberry Pi and run the "ifconfig" command. 4. From there I get the MAC address for eth0 --> in my case: b8:27:eb:29:a9:25 5. Then, back in Codesys I double click on "EtherCAT Master" in the left hand tree. I then paste the MAC address into the "Source Address (MAC)" field. 6. I go to the Beckhoff official website and download the XML files for EtherCAT: https://www.beckhoff.com/en-en/products/i-o/ethercat-terminals/ek1xxx-bk1xx0-ethercat-coupler/ek1100.html? 7. I unzip those files in my computer into some folder that I can remember. 8. Back in Codesys I click on "Tools" --> "Device Repository" --> "Install" --> and then on the "Beckhoff EK11xx.XML" file. 9. In theory the necessary XML file is now installed. 10. THIS IS WHERE I RUN INTO THE PROBLEM: I then click on login --> I right click on EtherCAT_Master and then scan for devices --> and nothing. 11. It just doesn't detect it. On top of this whenever I login I get those orange triangles on the left on my tree. When I check the Log I get the messages at the very first screenshot of this post. SEE FOURTH PICTURE Solutions that I have tried to resolve this problem: 1. I thought it was maybe the .XML file so I installed all the .XML files from the EtherCAT folder that I downloaded. That didn't fix it. 2. I went on the Wayback Machine and got the .XML files from 2018 as I thought maybe an older version would work. This file of EtherCAT folders had a .XML file named "Beckhoff EKxxxx.XML" I thought this would work because that's the name of the file the guy in the Instructables used (https://www.instructables.com/Programming-Raspberry-Pi-With-CODESYS/). That didn't do anything. 3. I ran the PLC on my computer instead of the Raspberry Pi and tried to connect to the EK1100, in case the issue was with the Raspberry Pi, but I still ran into the same error from the picture above: "Attention! The device was not found in the repository. Vendorcode: 0x0. Productcode: 0x0. Revision: 0x0". SEE FIFTH PICTURE 4. I reinstalled Codesys, I was originally on version 3.5 SP20 when I did this, I upgraded to 3.5 SP21 with no success. 5. I then thought the solution might be to first add the EK1100 hardware before connecting so I did the following: 6. Right click on "EtherCAT Master" on the left hand tree --> then click on "add device" --> then I added the "EK1100 EtherCAT Coupler (2A E-Bus)" MY THEORY OF WHAT IS CAUSING THE PROBLEM: I asked ChatGPT for help and it said that it might have something to do with the revision number. On the physical EK1100 it says "Rev. Nr.: 0018". I believe that this means that I need to a revision 0018 XML file but if you look in Codesys it says the version is 16 (picture above). This is confusing because I got my .XML file from the official Codesys website so it should be the most up to date version possible. I searched and I searched and I couldn't find a version 18 .XML file, I don't even now if this exists. Any help you can provide is greatly appreciated, I don't know what to do anymore and I really really want to get this working. Thank you!
Last updated: 2025-03-30
Post by eschwellinger on communication
CODESYS Forge
talk
(Post)
depends on if you use PFC200 SL from CODESYS store or the Wago target for the PFC. If you use the SL product you need to setup the interface by a plcshell command...
Last updated: 2023-08-19
Post by jegerjon on Find index based on values
CODESYS Forge
talk
(Post)
Hi, I need to figure out witch indexes of an Array containing the highest and lowest values. Typically search for the 5 lowest values and result the indexnumbers containing the 5 lovest values. is there a library for this, or codeexample?
Last updated: 2023-08-20
Post by jegerjon on Find index based on values
CODESYS Forge
talk
(Post)
Hi, I need to figure out witch indexes of an Array containing the highest and lowest values. Typically search for the 5 lowest values and result the indexnumbers containing the 5 lovest values. is there a library for this, or codeexample?
Last updated: 2023-08-20
Post by shooxplc on How to call the same program from library and get the vars updated.
CODESYS Forge
talk
(Post)
Hi, I am writing to you today because I would like to create a library that would contain a program with its various subprograms, in my example "PLC_PRG" with "a", "aa", "aaa". But once the library is created as shown below: I would like to be able to drag and drop my folder as many times as I want (let's say I manage the same system multiple times). Once the drag and drop is done, we can see the second folder with the variables renamed successfully. As shown below: But my variables in CAD_1 remain the same as for CAD, so it's PLC_PRG instead of PLC_PRG_1, for example. Is there a solution to automate this? I wouldn't want to have to rename all my variables manually, considering that in the program where I want to do this, the number of variables is substantial. Lucas.
Last updated: 2023-08-23
Post by eschwellinger on Stop raspberry from executing a plc program
CODESYS Forge
talk
(Post)
/var/opt/codesys/PLCLogic as soon you have dowloaded the project to the Pi it will run the bootapplication no connection to the pc is needed anymore
Last updated: 2023-08-24
Post by eschwellinger on Connection to device closed
CODESYS Forge
talk
(Post)
is there a way to check the plclog on Opus A3 by using cmd line under Linux? This log is what you need to check for the disconnection problem
Last updated: 2023-08-24
Post by bagusd on gateway problem
CODESYS Forge
talk
(Post)
hello, I have a problem with the gateway not being able to connect to the plc, does anyone know why the gateway is difficult to connect to the plc? even though the lan cable has been connected to the plc and codesys gateway V3 has been restarted, thank you
Last updated: 2023-08-25
Post by eschwellinger on How to configure CODESYSControl_User.cfg in order to use a specific network card for OPCUA Server
CODESYS Forge
talk
(Post)
check this faq section here: https://faq.codesys.com/plugins/servlet/mobile?contentId=102137886#content/view/102137886
Last updated: 2023-08-25
Post by eschwellinger on How to configure CODESYSControl_User.cfg in order to use a specific network card for OPCUA Server
CODESYS Forge
talk
(Post)
Hi Rossano, thank you for the feedback, you are right this need to be changed in the faq section. Regards Edwin
Last updated: 2023-08-28
Post by yr00 on OPC UA datasource low read frequency
CODESYS Forge
talk
(Post)
Hello everyone, I am trying to test the OPC UA client feature in Codesys. My setup is the following; I have a Codesys simulation/ visualization running on Control Win V3. My OPC UA server is hosted on a Siemens 1518 PLC using PLCSim Advanced. The setup is completely virtual so there are no really PLCs. Everything is on my laptop. Writing data from the Codesys simualtion to the server is very quick. I have a PLC program running on another 1500 PLC which reads data from simulation via the server, and changes in the simulation (e.g. button pressed) appear within hundreds of miliseconds if not tens of miliseconds in my PLC program. However, when it comes to reading data from the OPC UA Server by Codesys, it taks around 1-2s. I connected a UAExpert client and it gets update very quickly so I am fairly sure the problem is with Codesys. I have tried changing the update rate in datasource -> General and Diagnosis, but it doesn't seem to have an effect. Do you guys have any suggestion on what I can do?
Last updated: 2023-08-29
Post by eschwellinger on CSVReaderInit returns error : INVALID_HANDLE
CODESYS Forge
talk
(Post)
this is a security issue not to read/write in the plc allowed path I would recommend to update and change the path in the application were the files are😏
Last updated: 2023-08-30
Post by totorovic on CSVReaderInit returns error : INVALID_HANDLE
CODESYS Forge
talk
(Post)
Thank you for the return. The path targets to a CFast card. User has R/W access to it. We will try to change it.
Last updated: 2023-08-31
Post by marekxc on Error C0521 - unknow compiler
CODESYS Forge
talk
(Post)
Select in tree "DEVICE", right-click and select "Update Device" Select "Library manager" and Change the version of the Library (down manualy). Samoetimes "Try reload Library". If you open a project version 3.5.19 in version 3.5.16, there are difficulties.
Last updated: 2023-09-02
Post by eschwellinger on Ethercat scan for devices not picking up EL7041 as a softmotion axis
CODESYS Forge
talk
(Post)
Add existing version (with SM drive) - without scan - disable under expert settings in the slave the revision check.
Last updated: 2023-09-03
Post by jinil on Import RsLogix 5000 project to Codesys
CODESYS Forge
talk
(Post)
Hello, I am trying to do the same thing. I want my Rslogix 5000 project into Codesys. Was wondering if you have found a way to do it. Thank you.
Last updated: 2023-09-07
Post by jinil on Import RsLogix 5000 project to Codesys
CODESYS Forge
talk
(Post)
Hello, I am trying to do the same thing. I want my Rslogix 5000 project into Codesys. Was wondering if you have found a way to do it. Thank you.
Last updated: 2023-09-07
Post by eschwellinger on Device User Logon and No device is responding.. Pi4b codesys 3.5 SP19 2 + (64-bit)
CODESYS Forge
talk
(Post)
please use latest version 4.9.0.0 and it is mandatory to have a user pi on your device.
Last updated: 2023-09-11
Post by eschwellinger on RPI Zero w - Edge gateway cant install
CODESYS Forge
talk
(Post)
check 'uname -a' by ssh connection - addtional you'll probaly find the reason for not running with application by 'cat /var/opt/codesys/codesyscontrol.log' incase you are using 4.9.0.0 runtime version
Last updated: 2023-09-13
Post by eschwellinger on RPI Zero w - Edge gateway cant install
CODESYS Forge
talk
(Post)
ok now it is clear - this is a single core Pi Zero W. For this device there is no edge device available. But just for working with CODESYS it is not really needed and yes plc runs only for 2h unlicensed.
Last updated: 2023-09-13
Post by transmin01 on Correct CAN Driver for EL6751
CODESYS Forge
talk
(Post)
Hi, does anyone know what is the correct driver name that needs to go into the CodesysControl.cfg file for a Beckhoff EL6751? TIA Trevor.
Last updated: 2023-09-19
Post by marsmaennchen on llcallback() iec exception caught cmpid=0x00000002, eventid=0x00010008
CODESYS Forge
talk
(Post)
Never found a solution for that, or an answere that maker sense. Have you found out something New? Greetings Patrick.
Last updated: 2023-09-24
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.