Post by rabaggett on CODESYS control for Raspberry Pi 64 SL errors CODESYS Forge talk (Post)
Hi, I am trying to create a project using a raspberry pi, I have added the modules for the Pi and MCP3008. I have encountered som errors that I don't know how to track down. 1. The GPIOs give preprocessor errors, but I read that this does not prevent compiling. This seems to be true. I can build the empty project with no errors. 2. After adding a SPI master and MCP3008, the preprocessor errors double, but seem similar and the project again builds with no errors. 3. I add a DUT and GVL, with a function, and I get the following errors. They remain even if I delete these things. ------ Build started: Application: Device.Application ------- Typify code... [ERROR] crr: C0032: Cannot convert type 'Unknown type: 'ADR(GVL_Io_17160064_c083_41f8_9e53_208be7537753_HPS_7.Io_17160064_c083_41f8_9e53_208be7537753_HPS_7)'' to type 'POINTER TO IoConfigParameter' [ERROR] crr: C0077: Unknown type: 'GVL_Io_17160064_c083_41f8_9e53_208be7537753_HPS_7.Io_17160064_c083_41f8_9e53_208be7537753_HPS_7' [ERROR] crr: C0046: Identifier 'GVL_Io_17160064_c083_41f8_9e53_208be7537753_HPS_7' not defined Compile complete -- 3 errors, 0 warnings I attach the project. What am I doing wrong? Thanks!
Last updated: 2024-05-02

Post by fredashbolt on Dynamically Update JSON Payload CODESYS Forge talk (Post)
I am trying to generate a JSON payload populated with a value that updates for use with a telemetry system, the payload is to be published by MQTT. I have established the MQTT client and can publish a working JSON payload but I can't get the payload to update as the value (iValue) changes. I am using a timer to trigger the .SetValue function periodically, but the JSON will only give the value as it is when it is first initialized using xFirst IF statement. Any suggestions? Thanks VAR pJsonData : POINTER TO JSON.JSONData := factory.Create(); fb_JBuilder : JSON.JSONBuilder; diRootIndex, diObject1Index : DINT; iValue : INT := 10 ; jsonArrayWriter : JSON.JSONByteArrayWriter; wsJsonData : WSTRING(1000); xFirst : BOOL := TRUE; utf8JsonData : STRING(2000); diTempVal : DINT ; PublishTimer : TON ; END_VAR IF xFirst = TRUE THEN fb_JBuilder ( pJsonData := pJsonData , diRootObj => diRootIndex ) ; diObject1Index := fb_Jbuilder.SetKeyWithObject ( "Device" , diParentIndex := diRootIndex ) ; diTempVal := fb_Jbuilder.SetKeyWithValue ( "Temp" , iValue , diParentIndex := diObject1Index ) ; xFirst := FALSE ; END_IF PublishTimer ( IN := PublishTimer.Q = 0 , PT := T#5S ) ; IF PublishTimer.Q THEN fb_JBuilder.SetValue ( iValue , diTempVal ) ; END_IF jsonArrayWriter( xExecute := PublishTimer.Q , pwData := ADR(wsJsonData), udiSize := SIZEOF(wsJsonData), jsonData := pJsonData^, xAsyncMode := FALSE ) ; JSON.Stu.ConvertUTF16toUTF8( ADR ( wsJsonData ) , ADR ( utf8JsonData ) , SIZEOF ( utf8JsonData ) , bStrictConversion := TRUE ) ;
Last updated: 2026-03-10

Post by taywinkel on Virtual Keyboard Support on Login Page CODESYS Forge talk (Post)
I am in the process of getting a visualization to work with the codesys keyboard. I created a custom keyboard which works fantastic for all input fields in the main visualization. I created a user management for my runtime, which gave me the standard blue login page. The codesys keyboard does not show up when trying to enter the usernam or password. I have tried every setting: changing the keyboard back to the standard codesys keyboard, and changing various settings on the visualization manager with no success. I can only use a physical keyboard connected to the device to enter the password. I did try removing the keyboard to no success either. I even tried creating my own login page so I could guarantee the keyboard showed up. This ended in disaster as I could not figure out the very complicated VisuUserManagement and VisuUserManagementDialog library, and documentation is contradictory or lacking. I imagine that an on screen keyboard is essential for many people's projects when using touchscreen panels, so I am wondering what others are doing. I would rather not use an external virtual keyboard (external to codesys) because this causes its own complications (I am working on a linux build with high securities).
Last updated: 2026-03-22

Post by gediminas on Datasource OPC UA client system failure CODESYS Forge talk (Post)
I am using CODESYS v3.5 SP20 Patch 3 / Control for BeagleboneBlack SL v4.13 and after some time the OPC UA Server crashes. However, Runtime still works without any issues. The events leading up to the OPC server crash are the most suspicious: 1) Mutex deadlock detected - owner thread died, and 2) Runtime received SIGABRT. And it seems very similar with this topic except used versions - issues should be fixed with previous SP's. I can't seem to find any information about these events. Need some pointers in the right direction on how I can fix this problem.
Last updated: 2024-10-25

Post by l-lll on The plug-in is required by the current version profile but has not been installed CODESYS Forge talk (Post)
Hello everyone, I meet this problem after installing Codesys SP20 Patch 5 on Windows 11 while the dialog box shows that the installation process has been successfully completed. Every time I open Codesys I get an error that says (Attached image): 'One or more issues ocurred with the current version profile. Please contact the vendor to resolve these problems. The plug-in {....} (Exactly x.x.x.x) is required by the current version profile., but has not been installed. It is highly recommended that the tools is terminated. Do you wanto to terminate now?' Can someone help me please, thanks very much!
Last updated: 2025-05-14

Post by l-lll on The plug-in is required by the current version profile but has not been installed CODESYS Forge talk (Post)
Hello everyone, I meet this problem after installing Codesys SP20 Patch 5 on Windows 11 while the dialog box shows that the installation process has been successfully completed. Every time I open Codesys I get an error that says (Attached image): 'One or more issues ocurred with the current version profile. Please contact the vendor to resolve these problems. The plug-in {....} (Exactly x.x.x.x) is required by the current version profile., but has not been installed. It is highly recommended that the tools is terminated. Do you wanto to terminate now?' Can someone help me please, thanks very much!
Last updated: 2025-05-14

Post by l-lll on The plug-in is required by the current version profile but has not been installed CODESYS Forge talk (Post)
Hello everyone, I meet this problem after installing Codesys SP20 Patch 5 on Windows 11 while the dialog box shows that the installation process has been successfully completed. Every time I open Codesys I get an error that says (Attached image): 'One or more issues ocurred with the current version profile. Please contact the vendor to resolve these problems. The plug-in {....} (Exactly x.x.x.x) is required by the current version profile., but has not been installed. It is highly recommended that the tools is terminated. Do you wanto to terminate now?' Can someone help me please, thanks very much!
Last updated: 2025-05-14

Post by milan-svarny on ModbusFB.ClientSerial Problem with Reply Timeout CODESYS Forge talk (Post)
Hi All, I have problem with ModbusFB.ClientSerial. I'm using 4 different port for Modbus communication. After some time of running program ClientSerial stops to receive data to reply buffer and all request finish with Reply Timeout. The Device sent reply correctly,that it is visible on oscilloscope and it is possible to see that data( reply )are in the device. If the usbtty device is read over external app. then it is possible to see all data which were not taken by ModbusFB.ClientSerial. The stack does not overflow or something , program runs correctly forward and no exceptions or something. The main problem it is that when the error occur than it is not possible to reset port or something or maybe i'm doing it wrong way. please help me with this issue. Thank you for any help in advice Milan
Last updated: 2025-05-23

Post by timvh on Profinet fault with codesys control V3 - Receive packet error CODESYS Forge talk (Post)
Are you using the Control Win SL (installed together with the development environment of CODESYS)? If yes, you might want to consider using the CODESYS RTE instead. This has real-time capabilities (running on separate core(s)). But to be able to use this, you have to install the CODESYS Ethernet driver for your network interface to be able to let the RTE access the network port also in realtime. See: https://store.codesys.com/en/codesys-control-rte-sl-bundle.html https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_windows_rts_v3.html PS, I haven't tested this myself yet, but you could try to use the SetCommunicationState method of the Profinet controller to see if you can reset and start the bus communication: result := PN_Controller.SetCommunicationState(eRequestedState := DED.DEVICE_TRANSITION_STATE.START); PS, if you are located in the Netherlands or Belgium, we could also provide the license(s) for you.
Last updated: 2024-02-28

Post by timvh on Profinet fault with codesys control V3 - Receive packet error CODESYS Forge talk (Post)
Are you using the Control Win SL (installed together with the development environment of CODESYS)? If yes, you might want to consider using the CODESYS RTE instead. This has real-time capabilities (running on separate core(s)). But to be able to use this, you have to install the CODESYS Ethernet driver for your network interface to be able to let the RTE access the network port also in realtime. See: https://store.codesys.com/en/codesys-control-rte-sl-bundle.html https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_windows_rts_v3.html PS, I haven't tested this myself yet, but you could try to use the SetCommunicationState method of the Profinet controller to see if you can reset and start the bus communication: result := PN_Controller.SetCommunicationState(eRequestedState := DED.DEVICE_TRANSITION_STATE.START); PS, if you are located in the Netherlands or Belgium, we could also provide the license(s) for you.
Last updated: 2024-02-28

Post by sumit on Not able to see input data coming from eip adapter on codesys CODESYS Forge talk (Post)
dhumphries, I changed the datatype this time from BYTE to USINT (because that's what my adapter is sending: array of uint8_t). The text "New Help String" you saw in previous screenshots is just the description of the input/s (it can be anything). I also looked into the logs (see attached) for that ! sign next to the device, I found that connection is being timeout. I tried some suggestions from online such as increase the RPI but still got connection timeout issue, also by changing the datatype, I still don't see incoming data from the adapter, although its visible on wireshark. thanks,
Last updated: 2024-03-07

Post by ragarcia on Error while using Codesys SP19 Patch 4 on Windows 11 CODESYS Forge talk (Post)
Hello everyone, I just installed Codesys SP19 Patch 4 on Windows 11 and every time I open Codesys I get an error that says (Attached image): 'One or more issues ocurred with the current versio profile. Please contact the vendor to resolve these problems. The plug-in {....} (Exactly 4.15.0.0) is required by the current version profile., but has not been installed. It is highly recommended that the tools is terminated. Do you wanto to terminate now?' I cannot install any package since I get this error everytime I open or try to install any package. Can someone help me please, thanks in advanced
Last updated: 2024-03-26

Post by baotthitawat on Cloud SCADA for Industrial Energy Monitoring CODESYS Forge talk (Post)
Recently I’ve been exploring ATSCADA iEnergy Tools for SCADA-based energy monitoring systems. One thing I find interesting is how modern SCADA platforms are evolving beyond traditional machine monitoring. Many industrial systems are now using Cloud SCADA architectures for centralized energy management, remote dashboards, and operational analytics. ATSCADA iEnergy Tools supports: Real-time energy monitoring Historical data logging MySQL integration Reporting and Excel export Remote SCADA dashboards Cloud-based monitoring systems I think this type of solution is practical for factories, power monitoring applications, building management systems, and other industrial automation projects where energy optimization is becoming increasingly important. Industrial automation is clearly moving toward web-based and cloud-connected SCADA platforms, especially as more facilities focus on digital transformation and smarter energy management
Last updated: 2026-05-26

Post by baotthitawat on Cloud SCADA for Industrial Energy Monitoring CODESYS Forge talk (Post)
Recently I’ve been exploring ATSCADA iEnergy Tools for SCADA-based energy monitoring systems. One thing I find interesting is how modern SCADA platforms are evolving beyond traditional machine monitoring. Many industrial systems are now using Cloud SCADA architectures for centralized energy management, remote dashboards, and operational analytics. ATSCADA iEnergy Tools supports: Real-time energy monitoring Historical data logging MySQL integration Reporting and Excel export Remote SCADA dashboards Cloud-based monitoring systems I think this type of solution is practical for factories, power monitoring applications, building management systems, and other industrial automation projects where energy optimization is becoming increasingly important. Industrial automation is clearly moving toward web-based and cloud-connected SCADA platforms, especially as more facilities focus on digital transformation and smarter energy management
Last updated: 2026-05-26

Post by manuknecht on Specify Input Configuration "OnDialogClosed" Action to only react to certain Dialogs CODESYS Forge talk (Post)
I have a project with several buttons and dialogs. Most of the dialogs are opened using the Open Dialog action of the Input configuration of the buttons. Some dialogs are openend using the FbOpenDialogExtended FB of the Visu Utils library and the FbOpenDialogExtended FB is called in the Execute ST-Code action. I am also using the FileOpenSave dialog from Visu Dialogs which requires an OnDialogClosed action to read out. I realized that the OnDialogClosed action which is meant for the FileOpenSave dialog also triggers if a dialog is closed, which was previously openend using the FbOpenDialogExtended FB. Is there a way to detect which dialog was closed last and specify to which dialogs the OnDialogClosed action reacts?
Last updated: 2023-09-20

Post by simotion on Pointer to Softmotion axis CODESYS Forge talk (Post)
In my projet I use Softmotion. There are several Softmotion axis (type SM_Drive_Virtual). In the Global Variable List I have an array of pointers to the adress of the Axis. Axis : ARRAY[1..iMaxCntAxes] OF POINTER TO AXIS_REF_SM3 := ADR(AX01_Axis), // [1 ADR(AX02_Axis), // [2] This works, but when compiling I get the message : . [WARNING] E3D: GVL Device: PLC Logic: Application: C0564: A reference to uninitialized variable AX01_Axis is used for initialization of Axis. Accessing the uninitialized variable may result in unexpected behavior. [WARNING] E3D: GVL Device: PLC Logic: Application: C0564: A reference to uninitialized variable AX02_Axis is used for initialization of Axis. Accessing the uninitialized variable may result in unexpected behavior. Is there a way when initializing to force the hardware (softmotion axis) to first initialize and then the Global Variable List?
Last updated: 2023-10-25

Post by dhumphries on install codesys runtime on linux CODESYS Forge talk (Post)
I'm running the 3.5.18.20 IDE, installed the control for linux SL package from the installer. Following the directions here: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_install_runtime_on_controller.html it says: Installing the runtime package with CODESYS on the Linux device Click Tools → Update CODESYS Control for <device> SL.</device> I don't have the update option in my tools menu. I've tried it without opening a project, as well as with a project open that uses the control for linux SL as a device. I have found the update device option by right clicking on the device in the device tree, but this only lets me change the device the project is using not load the runtime on the linux computer. Is there an updated instruction somewhere, or do I need to do some further preparation like install additional packages?
Last updated: 2023-11-04

Post by kunz on Responsive Design Example CODESYS Forge talk (Post)
Hello everyone, I have a problem with the example project Responsive Design Example, which is available here in Codesys Forge. I wanted to try switching the visualization depending on the device type. To do this, I used a smartphone to access it. I can see via breakpoints that the Smartphone visualization is selected, but the visualization of the normal monitor still appears on the smartphone. Could there be a problem with the libraries, or why is the device not assigned the correct visualization page? I dont know how do further debuggin or troubleshooting. Here the page to the example: https://forge.codesys.com/prj/codesys-example/responsive-desi/home/Home/ Thank you very much.
Last updated: 2024-06-27

Post by lorenzo-pisoni on SysProcessExecuteCommand CODESYS Forge talk (Post)
Hello, I'm encountering an issue with the Sysprocess library while attempting to execute commands to transfer a file from a NAS to my PLC. Currently, I'm trying to test a simple "reboot" command, but it doesn't work as demonstrated in this video: https://youtu.be/77c7Af5xRhE?si=uFZdB6fTNQitzWMQ. I'm using CODESYS V3.5 SP18 Patch 4 (3.5.18.40). From other sources, I've learned that to enable the PLC to execute commands, I need to add the following line to the file CODESYSControl_User.txt: [SysProcess] Command=AllowAll However, the issue I'm facing is that this file doesn't exist on my CPU. I have full SSH access and can see all files, but only CODESYSControl.txt is present. Adding the command to CODESYSControl.txt hasn't resolved the problem.
Last updated: 2024-07-11

Post by ucconversions on displaying all incoming CAN bus messages CODESYS Forge talk (Post)
Hello Im using CAN API Im receiving CAN messages with no problem. below is my code. METHOD ProcessMessage VAR_IN_OUT ( Incoming message ) Message : CAN.RxMESSAGE; END_VAR VAR i: USINT; END_VAR recvCANid := Message.udiCanID; IF recvCANid = 16#18FF8247 THEN UserVarGlobal.g_countMsg_RPMset := UserVarGlobal.g_countMsg_RPMset + 1; FOR i := 0 TO 7 DO myDataFF82[i] := Message.abyData[i]; END_FOR END_IF but in this way I can only display CAN messages which I know its ID. I want to display all incoming CAN messages for example first incoming CAN message - I assign it into a variable Message1. second incoming CAN message - I assign it into a variable Message2. third incoming CAN message - I assign it into a variable Message3. Can you give me guidance? Thank you BR
Last updated: 2024-07-18

Post by peterned on Programatically restart Codesys OPC UA server? CODESYS Forge talk (Post)
Hi, I'm using a Festo Codesys PLC (CPX-CEC-C1-V3), which is connected to a HMI panel. Both exchange data via OPC UA. Occasionally, the HMI stops displaying data, and looks as if there is no connection. If the HMI stops, the only way to make it work again is to restart the PLC. Restarting HMI has no effect. When the PLC is restarted, HMI starts working normally again. Is it possible to restart the OPC UA server from PLC code? I hope this will make fixing the HMI possible without a PLC restart. Thanks
Last updated: 2024-07-19

Post by askic on Generate FBs from source CODESYS Forge talk (Post)
Hello, I'm coming from Siemens (TIA) world and currently learning Codesys. I'd like to know if there is an option to add external txt file with ST code for creation of a function block and then use this file as a source file from which FB will be generated? For example, in TIA, there is an option add external source file to the project structure and then use option "Generate blocks from source". This would create a FB. Does Codesys have something similar? This external source file would look like this: FUNCTION_BLOCK Scaling VAR_INPUT x, k, n : REAL; END_VAR VAR_OUTPUT y : REAL; END_VAR VAR END_VAR y := k*x+n; END_FUNCTION_BLOCK
Last updated: 2024-07-31

Post by expertplas on No connection to opc server from codesys opc client CODESYS Forge talk (Post)
Hello, we have aproblen to connect our CODESYS OPC Client to the OPC Server. We installed the client according the CODESYS manual. We can browse the server and variables can be linked to the PLC. I created a self signed certificate for the CmpOPCUAClent as described. The server has a cerificate also. I copied the certificates to the trusted zone of server and client. But when it comes to data exchange we get an error message. "Communication error in data source OPC UA Library. Error ID : 7001 German : "Kommunikatinsfehler inder Datenquelle OPC UA -Bibiothek. Es wurde kein genauer Fehler angegeben. Fehler ID : 7001" It semms that there is no cerificate exchange. We are working with CODESYS 3.5 SP19 Patch 5. Can anyone here say something about this error or has an idea for a solution? Thanks.
Last updated: 2024-08-19

Post by opineiro on How to manage variable types larger than 64 bits - Ethernet/IP CODESYS Forge talk (Post)
Hi there, I have a Keyence bar code reader connected to my plc through Ethernet/IP. The Bar code is 20 digits long (like 30100790020493036016), the scanner reads it correctly (I can verify that through the keyence software) but when it sends it through ETH/IP, it doesn't fit into a 64 bit variable and it trunks the data.(I've tried ULINT and LWord without success). When I loaded the EDS file, the read variable was defined as a byte with 128 bits length, which is quite strange for me. (see attached picture) How do I manage this variable? Thanks!
Last updated: 2024-09-23

Post by andrebrandt on FB string and naming CODESYS Forge talk (Post)
Hi Tim. Not quite correct. What i'd like, is when you place the FB in prog, i choose a block NTC10k, and name this RT401. What i'm trying to do, is to get the name RT401 automaticly into the FB, so i can put this into the string i pass in a struct. So in var in POU, i saw this a place i could do this, RT401: NTC10k(Tag:='RT401'), but i can't get this to work. I shurly must have had something like this in FB: FUNCTION_BLOCK NTC10k String TAG But it's here where I'm stuck...
Last updated: 2024-09-30