Post by alexgooi on Licensing info not available.
CODESYS Forge
talk
(Post)
Dear Forum I have the following config: Codesys_IDE 3.5.20 Codesys_Virtual_Control 4.13 Codesys_License_Server 4.13 I know these are not the newest versions, but in my mind these should work. I have the same problem here. I have the license server installed on the host, and in the docker container(Codesys virtual control) I'm able to ping the license server. In the /conf/codesyscontrol/CODESYSControl_User.cfg I have added the following config: [CmpCodeMeter] EnableNetLicenses=1 LicenseServer.1="ip address of the host" I have tried it via the wbm web-page. I can create new license containers over there, but still no luck. I also have tried to run the docker container with the -s "server_IP" command. I have searched for some tutorial's but I couldn't find it. If anyone has some clue or can give me a push in the right direction it would be very very welcome!
Last updated: 2025-09-29
Post by alexgooi on Licensing info not available.
CODESYS Forge
talk
(Post)
Thank you for your quick response, I have updated to the 4.17.0 (Virtual control and the license server). Now I am able to see the softcontainer from the Codesys IDE. But when I want to activate the license I get the following message: Licensing info not available. The device does not support this service (See picture). I then tried to active it via the WBM service like you suggested. But when I try this is get an error (see picture for error). I also tried to put RTS- in front of the serial number, but when I try this I get an error that the serial number is not correct. I think I'm getting closer, but I'm not there yet.
Last updated: 2025-10-01
Post by kevinl on RevPi Connect RS485
CODESYS Forge
talk
(Post)
I figured this out on my own with this logic: usually the Serial port on a Raspberry pi is on /dev/ttyUSB0 then you need to set linux.DeviceFile=/dev/ttyUSB in codesys you then must set com port to 1 so i assumed codesys subtracts 1 from the number and adds this to the filename... (in code it would look like this: var comPort : byte := '1'; linuxDevice : string := '/dev/ttyUSB'; filename : string; end_var filename := concat(linuxDevice, (to_string(comPort-1)); filaname then is /dev/ttyUSB0 RevPi uses ttyRS485 as Serial port so you must remove the last number from the name and set the com port to this number +1 i hope this is understandable ;-)
Last updated: 2023-12-11
Post by niloufar on Execution Order of Function Blocks
CODESYS Forge
talk
(Post)
Hi, Our program incorporates various function blocks and programs written in different languages such as St and SFC. They implement numerous actions and methods using different languages from their function blocks. My question is whether the execution order of function blocks is associated with the programming languages used. I understand that cycle time can be configured in the task configuration, but I'm curious if there is a specific sequence order of execution for function blocks written in different languages. For example, all function blocks in (ST) are executed first, followed by the execution of (SFC). Specifically, when the function is written in (ST) and the action is implemented in (SFC). I modified all function blocks in the main PLC program and configured a task configuration for the main program.
Last updated: 2023-12-13
Post by royw on Profinet library for C#
CODESYS Forge
talk
(Post)
Hi, I don't know if I'm in the right place or if it's even possible... I'm looking for a way to address a Profinet device with Record Read and Write from my own PC. I actually only need very few commands to configure our device. This means setting the MAC address and a serial number. We would like to do this from a C# program. Now we are looking for a library or something similar. Since you can do it from Codesys, I thought there might be a DLL or something similar that you could use for this. As I said, we don't want real-time queries of the cyclic data but only record read/write. Does anyone have any helpful hint? Thanks in advance
Last updated: 2023-12-22
Post by idalu on Profinet PN_Controller Issue, Network Adapter
CODESYS Forge
talk
(Post)
i have a problem with Profinet on my project. I'm using Codesys RTE 3.5.19.50. When i download program to controller the ethernet is ok, PN_Controller is ok but every device i'm trying to connect is red with error "DCP no RealStationName". When i'm trying to Scan for Devices on PN_Controller there are no devices found. I have installed Codesys driver CmpEt1000Drv to my network adapter (i'm sure it is right intel pro 1000 model). I have noticed that when i installed codesys driver i'm no longer able to ping this network adapter (i can ping it when intel driver is installed). On my previous projects with runetimes i can ping it even with codesys driver installed. I have also tried to do downgrade of everything to version 3.5.19.20 and it not helped.
Last updated: 2024-01-17
Post by tama00 on Datenübertragung mit SSP0 zw. uC und Raspberry Pi mit Codesys Runtime
CODESYS Forge
talk
(Post)
Hallo zusammen, ich arbeite derzeit an einem Projekt, bei dem ich einen Microcontroller habe, der Messwerte über die SSP0-Schnittstelle an einen Raspberry Pi senden soll. Diese Daten sollen dann in Codesys für eine Soll/Istwert Vergleich/Regelung verwendet werden, und das Ergebnis soll zurück an den Microcontroller geschickt werden. Meine Frage ist, ob es möglich ist, diese Kommunikation über die SSP0-Schnittstelle (als SPI frame format) zu realisieren, oder ob ich auf eine 'reine' SPI-Schnittstelle des uCs zurückzugreifen muss. Gibt es spezielle Dinge, die ich beachten muss, um diese Datenübertragung erfolgreich in Codesys zu implementieren? Ich wäre sehr dankbar für Ratschläge oder Hinweise, wie ich dieses Vorhaben am besten umsetzen kann. Vielen Dank im Voraus!
Last updated: 2024-01-31
Post by tama00 on Datenübertragung mit SSP0 zw. uC und Raspberry Pi mit Codesys Runtime
CODESYS Forge
talk
(Post)
Hallo zusammen, ich arbeite derzeit an einem Projekt, bei dem ich einen Microcontroller habe, der Messwerte über die SSP0-Schnittstelle an einen Raspberry Pi senden soll. Diese Daten sollen dann in Codesys für eine Soll/Istwert Vergleich/Regelung verwendet werden, und das Ergebnis soll zurück an den Microcontroller geschickt werden. Meine Frage ist, ob es möglich ist, diese Kommunikation über die SSP0-Schnittstelle (als SPI frame format) zu realisieren, oder ob ich auf eine 'reine' SPI-Schnittstelle des uCs zurückzugreifen muss. Gibt es spezielle Dinge, die ich beachten muss, um diese Datenübertragung erfolgreich in Codesys zu implementieren? Ich wäre sehr dankbar für Ratschläge oder Hinweise, wie ich dieses Vorhaben am besten umsetzen kann. Vielen Dank im Voraus!
Last updated: 2024-01-31
Post by tama00 on Datenübertragung mit SSP0 zw. uC und Raspberry Pi mit Codesys Runtime
CODESYS Forge
talk
(Post)
Hallo zusammen, ich arbeite derzeit an einem Projekt, bei dem ich einen Microcontroller habe, der Messwerte über die SSP0-Schnittstelle an einen Raspberry Pi senden soll. Diese Daten sollen dann in Codesys für eine Soll/Istwert Vergleich/Regelung verwendet werden, und das Ergebnis soll zurück an den Microcontroller geschickt werden. Meine Frage ist, ob es möglich ist, diese Kommunikation über die SSP0-Schnittstelle (als SPI frame format) zu realisieren, oder ob ich auf eine 'reine' SPI-Schnittstelle des uCs zurückzugreifen muss. Gibt es spezielle Dinge, die ich beachten muss, um diese Datenübertragung erfolgreich in Codesys zu implementieren? Ich wäre sehr dankbar für Ratschläge oder Hinweise, wie ich dieses Vorhaben am besten umsetzen kann. Vielen Dank im Voraus!
Last updated: 2024-01-31
Post by dhumphries on No source code available
CODESYS Forge
talk
(Post)
Try using an Ethernet/IP scanner instead of an adapter, I'm guessing the 2 devices you're trying to communicate with are adapters, you have to have a scanner somewhere and Codesys should be a scanner. I don't know why you're getting the error, you should be able to use your Ethernet port as an EthernetIP adapter (although I've never had a reason to try,) but it's probably not what you wanted to do, unless you're connecting to another PLC that is a scanner. Good luck configuring the devices you're trying to connect to, it will be a lot easier if you have an .EDS file instead of starting with a generic module, even with an .EDS it can be tricky getting the communication working.
Last updated: 2024-02-03
Post by arundara on OPC UA Server Stops after 5 consecutive disconnections of ethernet port
CODESYS Forge
talk
(Post)
Hello Every one, During testing of OPC UA communication between UA Expert software and the CODESYS SoftPLC on a Linux environment, an observation was made. When the Ethernet cable was disconnected and reconnected with 2-minute intervals, on the 5th attempt, the OPC UA connection failed to establish in UA Expert software. At this juncture, restarting the CODESYS SoftPLC enabled the reestablishment of OPC UA communication. The same result was obtained when testing on a Raspberry Pi SoftPLC. What is the reason behind this phenomenon? and whether there are settings to stop this behavior? Please help. Thanks & Regards.
Last updated: 2024-02-13
Post by ewi04 on How to upload application file to remote controller (offline) ?
CODESYS Forge
talk
(Post)
Thank you very much for your time and replay! Sounds like a good idea. Unfortunately, I have no other option to run the code from the running plc. So, I can’t stop any services. If anyone has the same problem, I've gotten a little closer to understanding it: Sometimes the copied files are empty after the restart. The update code checks if there are any empty files. Before I turn off the device, everything is okay. But after starting, some files are suddenly empty and that cause the problems. I don't know why this happens.
Last updated: 2024-02-16
Post by bschraud on Zielsystem stimmt nicht mit dem verbundenen Gerät überein
CODESYS Forge
talk
(Post)
Hallo, nach einer Umrüstung des RPi auf SSD habe ich den RPi neu aufgesetzt. Nach dem Installieren der Runtime (4.11.0.0 raspberry, all) auf den RPi kann ich das Gerät nicht mehr verbinden. Die Fehlermeldung lautet "Das gewählte Zielsystem 'Codesys Control for Raspberry Pi MC SL' stimmt nicht mit dem verbundenen Gerät 'Codesys Control for Raspberry Pi 64SL' überein. ID-Diskrepanz: Ausgewählt=000 0011, Online=0000 0012" Bei der Konfiguration des Laufzeitsystems kann man nur Multicore 64-bit (Aarch64) auswählen. Beim Aktualisieren des Gerätes im Gerätebaum habe ich Raspberry Pi MC SL in der Version 4.11.0.0 ausgewählt. Diese Version habe ich auch ausgewählt, weil nur diese Version für den produktiven Einsatz zugelassen ist. Die codesys Version ist frisch installiert, also 3.5.19.60 Vielen Dank für Ihre Hilfe
Last updated: 2024-03-08
Post by wmoon on Licensing info not available.
CODESYS Forge
talk
(Post)
Hello, I bought some licenses from CODESYS store. I am trying to install licenses into my device(CODESYS Control for Linux ARM64 SL). But I have a trouble with it. I did it in the following order. Tool -> License Manager Selected Device and Next... Selected Soft container and Next... Select the device and Ok.. And then I always show a message "Licensing info not available. There is no dongle attached to the device." And I tried to click "Install Licenses" button. I saw the message "The value cannot be NULL. Parameter name : continerToLicenses" Could you let me know what I've missed or what I've got wrong?
Last updated: 2024-03-19
Post by mani-i4point0 on Issue with WebVisu on Raspberry PI
CODESYS Forge
talk
(Post)
Hi, I am running Codesys Runtime by purchasing 'Codesys control for raspberry pi MC SL', I am trying to use the Variables from my GVL's. Few of the variables used as a Pushbutton form the Visualization. These 'BOOL' Variable getting unlatched automatically even though there is no write function in the Overall project. All of them are 'Read' functions, at the same time few other BOOL variable behaviors are seems to be fine. I have tried, clean all and download, serval time restarted the hardware. Happy to share any any information. Your input to resolve this issue would be highly appriciated. Version Details: codesyscontrol 4.8.0.0, armhf codesyscontrol based on SDK 3.5.19.0
Last updated: 2024-03-20
Post by albzen on EtherCat Slaves diagnosis
CODESYS Forge
talk
(Post)
Hello everybody, I'm working on a RunTime Plc (Codesys 3.5.16/18.20) connected to an EtherCat bus with many devices. The bus has some communication fault but I don't know how understand which is the device or the cable that has the trouble. To understand the cause of the problem I would like to read the WKC (Working counter) of the devices (0x0300...0x030C), how is explained in EtherCat documents, but it seems that the read of the counter is disabled. Attached there is an extract of the Ethercat document. Can anyone give me some advice about how and with function can I read it. Thank you in advance!
Last updated: 2024-03-29
Post by albzen on EtherCat Slaves diagnosis
CODESYS Forge
talk
(Post)
Hello everybody, I'm working on a RunTime Plc (Codesys 3.5.16/18.20) connected to an EtherCat bus with many devices. The bus has some communication fault but I don't know how understand which is the device or the cable that has the trouble. To understand the cause of the problem I would like to read the WKC (Working counter) of the devices (0x0300...0x030C), how is explained in EtherCat documents, but it seems that the read of the counter is disabled. Attached there is an extract of the Ethercat document. Can anyone give me some advice about how and with function can I read it. Thank you in advance!
Last updated: 2024-03-29
Post by bschraud on Unerwünschte Username- und Passwortabfrage im Browserfenster
CODESYS Forge
talk
(Post)
Hallo, nach der Portierung meiner Applikation von Codesys Version 3.5.18 auf 3.5.20 habe ich u.a. folgende Baustelle: Wenn in der Datei /etc/CODESYSControl_User.cfg die Einträge [SysProcess] Command=AllowAll und [CmpWebServerHandlerV3] AllowFileTransferServices=1 ergänzt werden, startet die Webvisu mit einer Login Abfrage. Die Webvisu soll aber (wie bisher auch) ohne Benutzeraktion starten. Den Browser für die Webvisu rufe ich mit dem Eintrag @firefox --kiosk --private-window localhost:8080/webvisu.htm in der autostart Datei auf. Wie kann man die Login-Abfrage wieder loswerden? Die Runtime läuft auf einem RPi mit Kernel Version 6.1.21 (aarch64) Vielen Dank für die Hilfe
Last updated: 2024-04-02
Post by dhumphries on How to determine code size
CODESYS Forge
talk
(Post)
I'm trying to determine which Codesys Control license I need, the Control Standard S has all the features I think I'll need, but the code size is limited to 3mb, I created a simple program with only 1 line of ladder logic and a simple visualization with a button and an indicator. When I generate code I get some messages, one indicates that the total allocated memory size for code and data is 2.1mb. Is this metric the correct size of the code? I question the size because it exceeds the allowable code size for the Basic S and Basic M licenses and consumes 2/3 of the available memory for the Basic L or Standard S license. What tool can I use to estimate the size of code as it relates to the runtime license limit?
Last updated: 2024-04-05
Post by sachem on Problem retain values Weidmuller UC20-WL2000
CODESYS Forge
talk
(Post)
Good afternoon. I am working with a weidmuller uc20-wl2000 controller, using a codesys license. We made a ladder code to control a process, and it works well, but we want some variables to remain stored even when the controller is turned off. We tried to use retain variables, but at the time of loading the program, when we went offline from the controller, the program was deleted, it did not remain in the controller, and in the same way if we turned off the controller. In addition to this, when we tried to program it again, the program would not stay loaded and began to present errors with the opc-ua communication. What could be causing this problem? How can we maintain the values of the variables without damaging the program or affecting the controller? thank you
Last updated: 2024-04-10
Post by valenting on Can't use new licensing with Raspberry Pi
CODESYS Forge
talk
(Post)
Hi, I'm using Codesys control for Raspberry Pi in the latest version (4.11.0.0) When I try to install a license with the new application-based licensing, I have an error "returncode 403046401" (using codesys SP18) I updated to codesys SP20, and now I get the following error: "The selected conainer [0]: SN=..., Version=1.18, Chip=0, Rev=0 does not fit to your ticket. Please select a suitable one." The license I'm trying to install is a Codesys Control Basic L license, with a Codesys Visualization L option, according to the needs of my application. What can I do to activate my license ?
Last updated: 2024-04-22
Post by fontrap on cmDongle Raspberry Pi issue
CODESYS Forge
talk
(Post)
Good morning @eschwellinger, After some research I found out that the problem is the preinstalled CodeMeter on Raspberry Pi. As I mentioned the CodeMeter was installed on the Raspberry because I use a license from other vendor that needs the CodeMeter to be installed. The problem is that when I uninstall the CodeMeter from Raspberry I am able to detect the dongle from CODESYS and everything works as it should be but now the other product can not detect its own license. When I reinstall the CodeMeter I am back to the initial problem. Is there a way to overcome this conflict through CODESYS?
Last updated: 2024-04-24
Post by wbj0t on connect IDE to plc that uses modem ppp
CODESYS Forge
talk
(Post)
Hello everyone! I have an PLC device that uses modem ppp connection to the internet with white IP. Device PPP connection with modem operator established, so I can connect to this device via SSH also within Codesys IDE (check version, info, etc...) BUT, I cant establish connection to this device in the device gateway options for application upload and debugging. How can I do this? Im trying set my device remote IP and port 11740, but, as I understand, it is wrong decision, because the next logic in this connection: local W10 service (Codesys Gateway) listen on 1217, then (some how) this service scanning local networks for seeking any local IP which listening on port 11740, and then connects and writes there. OR IM WRONG?:) W10 tool 'Test-NetConnection' with parameters 'ip -Port 11740' succeeded with True. Need some help, please :)
Last updated: 2024-05-21
Post by lzml on Safety
CODESYS Forge
talk
(Post)
I have a problem with a project that uses EtherCAT Safety. The project is developed with CODESYS version 3.5.19.20, runtime 3.5.18.30, safety CPU EL6900 4.3.1.0, TCEL6900FBS 3.5.1.10, IODrvEL6900 4.3.1.0, IODrvEtherCAT 4.1.0.0. The safety project works correctly, but when I download the PLC project for modifications, the ESM objects are no longer aligned with the states inside the safety program. Specifically, inside the safety program, they are seen as true, while outside the safety program, the state is reported as false, but not for all ESMs, only some. I have already tried to completely redo the safety from scratch, but nothing has changed. Any solutions? Thanks
Last updated: 2024-05-24
Post by damian177 on CM4S GPIO's in Codesys
CODESYS Forge
talk
(Post)
Hi, I am running my application on device based on Compute Module 4S (Cortex-A72 (ARMv8) 64-bit ). On this device I installed RPi Runtime in 4.11.0.0 version. In my project I use device: Codesys Control for Raspberry Pi 64SL and my project works, but I actually do not have acces to all GPIO's , because GPIOs Compute Module is available only in 3.5.16.0 version and it doesn't work. Properly work GPIOs B+/Pi2 but using this device I do not have acces to all GPIO's in CM4S. Anyone of can tell me how add GPIOs Compute Module 4.11.0.0 to my project ?
Last updated: 2024-05-28