Post by reinier-geers on License problem gateway CODESYS Forge talk (Post)
By browser is not working. Tim suggestet to use Codesys and stick in the laptop. Thats working. But now with a stick with licence but no running motion.
Last updated: 2024-04-25

Post by alex2 on Codesys SVN CODESYS Forge talk (Post)
Thank you for your answer. So i assumed correctly... And yes thats pretty expensive... Having to pay that much only for SVN / Git. we will look for that.
Last updated: 2024-04-29

Post by yannick on Raspberry PI 5 not working CODESYS Forge talk (Post)
Thanks for your quick help. It's working until I do a reboot of the raspberry PI. After that it goes back to 2024-04-20. How's that possible?
Last updated: 2024-04-29

Post by k2saki on CNC Override speed. SMC_Interpolator.dOverride is working ? CODESYS Forge talk (Post)
Hello. I have a question about override of moving speed. I am testing G-Code in Simulation mode. I set SMC_Interpolator.dOverride <--- 0.5, 1.0, 2.0 when Interpolator is working But SMC_Interpolator.dVel(speed) did not changed at all. Am I missing something to take effect ?
Last updated: 2024-05-01

Post by hyet on IoDrvModbusTCP_Diag not defined when using MODBUS CODESYS Forge talk (Post)
Currently seeing the same issue here, with a project moved from 3.5.19. Diving into it too to see if i can find the cause
Last updated: 2024-05-01

Post by radekkoza on How to use GPIO (and IOT2000 IO-Module) with CODESYS Control for IOT2000 SL ? CODESYS Forge talk (Post)
Hi I have this question I can't find anywhere what pins Di3 and Di4 have all the rest work . I have a 10 input iot2000 card
Last updated: 2024-05-05

Post by radekkoza on How to use GPIO (and IOT2000 IO-Module) with CODESYS Control for IOT2000 SL ? CODESYS Forge talk (Post)
Hi I have this question I can't find anywhere what pins Di3 and Di4 have all the rest work . I have a 10 input iot2000 card
Last updated: 2024-05-05

Post by corriibme on Profinet IO-link master - IODD files CODESYS Forge talk (Post)
I am having the same problem right now. Could you please share more information if you were able to solve the problem?
Last updated: 2024-05-05

Post by radekkoza on How to use GPIO (and IOT2000 IO-Module) with CODESYS Control for IOT2000 SL ? CODESYS Forge talk (Post)
Hi I have this question I can't find anywhere what pins Di3 and Di4 have all the rest work . I have a 10 input iot2000 card
Last updated: 2024-05-05

Post by tama00 on GPIOs not running with Raspberry Pi 4 (and SPI connection) CODESYS Forge talk (Post)
Hello everyone, I have a working SPI connection (with transferExt) between a Raspberry master with Codesys and an ESP32 slave. I would also like to use a few GPIO pins. Is there a problem with using SPI AND GPIOs? Environment: Raspberry Pi 4+ with Raspian from Oct 23 Codesys V3.4 SP19 Patch 5 with Runtime Version 4.10.0.0 Device: GPIOs B+/Pi2 My problem: The status is displayed as “GPIOs : not running”. And also during mapping the message “The bus is not running. The values shown are perhaps not actual”. However, the variable changes that I make in my program are displayed under “Current Value”. In the Logic Analyzer, the pin toggles during transmission with small intervals of +-4us (seems to be a cyclical disorder, but I don't know where exactly it could be coming from). This applies to pins that I actually use (output) but also to the other GPIOs (not used). With GPIO 4, the line remains permanently high. Attached is a screenshot from the Logic Analyzer. Channel 1,3,5 were GPIO pin 26, 22, 17 Would be very grateful for help. Best regards
Last updated: 2024-05-06

Post by mxj262 on FB having single input but initialized with Array CODESYS Forge talk (Post)
Ok yes now the loop has stopped when I set sum to zero before the for loop. Why will it retain the sum value from the last call?
Last updated: 2024-05-06

Post by alex-wall on Network Variables not updating CODESYS Forge talk (Post)
This worked for me. I had four identical PLC's. Three of them worked just fine with 255.255.255.255 as the broadcasting address but the 4th would not update the variables. Changed it to 192.168.x.255 and everything worked.
Last updated: 2024-05-07

Post by stiller on OPC-UA ApplicationUri / ProductUri CODESYS Forge talk (Post)
Hello! Is there a way to change ApplicationUri and ProductUri of the OPC_UA server? I can not find any information about it. Does someone have a clue? Thank you in advance!
Last updated: 2024-05-10

Post by dalfaro21 on Softmotion not working with simulation mode CODESYS Forge talk (Post)
I have a KEB combivis studio software running codesys and I want to make some moves but softmotion is not working on my laptop I hope you can help me!
Last updated: 2024-05-12

Post by eschwellinger on Ethercat bus on Beckhoff CX with Codesys for Linux CODESYS Forge talk (Post)
yes I think you need to build the kernel drivers for the CCAT driver for the backplane ETC networkcard https://github.com/Beckhoff/CCAT/
Last updated: 2024-05-13

Post by kevinm on Data source and safety PLC CODESYS Forge talk (Post)
I am having the same trouble. However, if I change the Login Configuration settings to 'Type: Login using the credentials determined at runtime' then the Connection information continues as 'Connection state: Connecting' and 'Error information: OK'. There is no User Management on the source PLC.
Last updated: 2024-05-16

Post by fugtwad on Automation Builder V2.5 EtherCAT CM579 Master Scan for devices - >No gateway selected CODESYS Forge talk (Post)
Scan from "IP-Configuration" with PC connected to first EtherCAT slave and "EtherCAT" tick box ticked gives slave info. As does ticking the "Emergency" tickbox.
Last updated: 2024-05-20

Post by hanoues on setting date and time on CPX-E CODESYS Forge talk (Post)
Hello, Can anybody here tell me how to modify the time and date on my CPX-E? I used the code I found on CODESYS online help, but it doesn't work. What am I missing? FUNCTION current_date_time : STRING VAR stUTC_Timestamp : SysTime; //utc time // ULINT#1528280694913 stLocal_TimeStamp : SysTime; //local time but is in general equal // ULINT#1528280694913 stdNow : SysTimeDate; //local time in an object to access each number (day, month...) dtNow : DATE_AND_TIME;//DT#2018-6-6-10:24:54 todNow : TIME_OF_DAY; // TOD#10:24:54.913 datNow : DATE; // D#2018-6-6 END_VAR SysTimeRtcHighResGet(stUTC_Timestamp); // ULINT#1528273494913 SysTimeRtcConvertHighResToLocal(stUTC_Timestamp, stdNow); //convert UTC ULINT to Local SysTime // stdNow.wYear = UINT#2018 // stdNow.wMonth = UINT#6 // stdNowy.wDay = UINT#6 // stdNow.wHour = UINT#10 // stdNow.wMinute = UINT#24 // stdNow.wSecond = UINT#54 // stdNow.wMilliseconds = UINT#913 // stdNow.wDayOfWeek = UINT#3 // stdNow.wYday = UINT#157 SysTimeRtcConvertDateToHighRes(stdNow, stLocal_TimeStamp); // ULINT#1528280694913 dtNow := TO_DT(stLocal_TimeStamp / 1000 ( ms )); // DT#2018-6-6-10:24:54 todNow := TO_TOD(stLocal_TimeStamp MOD TO_ULINT(T#1D)); // TOD#10:24:54.913 datNow := TO_DATE(dtNow); // D#2018-6-6 (convert to appropriate string) current_date_time := concat('$N[', TO_STRING(dtNow)); current_date_time:= concat(current_date_time,'.'); current_date_time:= concat(current_date_time, TO_STRING(stdNow.wMilliseconds)); current_date_time:= concat(current_date_time,'] - '); RETURN;
Last updated: 2024-05-21

Post by hanoues on Error 550 delete opertion failed CODESYS Forge talk (Post)
hello, Can anyone help me with my FTP problem on Windows 10? When I try to remove a folder, I can't, and it shows the error message 550.
Last updated: 2024-05-21

Post by rafaelbrito on Licensing info not available. CODESYS Forge talk (Post)
Hello, I'm having the same problem. I'm trying to license Codesys running in a Linux container, which I downloaded from the following link (https://hub.docker.com/r/hilschernetiotedge/codesys_control_sl_linux). The same error that you mentioned appears. Is there any solution?
Last updated: 2024-05-22

Post by william-blandon on RecipeManCommands.ReloadRecipes CODESYS Forge talk (Post)
Thanks Edwin. I have reviewed the example and I'm doing basically the same when calling the methods. The recipe files are in the right directory. Everything looks okay but simply it doesn't work. May migrating to Codesys 3.5.20 will solve this?
Last updated: 2024-05-24

Post by k2saki on Table How to set row number from 1 ( not from 0) CODESYS Forge talk (Post)
In Codesys visu, Table row number always start from 0. How do I set row number from 1 ?
Last updated: 2024-05-25

Post by donm on Regarding trend storage access error CODESYS Forge talk (Post)
i have created a project which contain 30 trend and suddenly trend recording is not working. its showing an error 30437."Determination of root pages for recording did not work for 'screen', error:30437" how to solve this issue?
Last updated: 2024-05-27

Post by donm on trend storage access error CODESYS Forge talk (Post)
i have created a project which contain 30 trend and suddenly trend recording is not working. its showing an error 30437."Determination of root pages for recording did not work for 'screen', error:30437" how to solve this issue?
Last updated: 2024-05-27

Post by k2saki on Open dialog from ST previous to version 3.5.6 CODESYS Forge talk (Post)
Thanks, that helps me a lot, but I have a question about this. https://forge.codesys.com/forge/talk/Engineering/thread/d8839077a0/
Last updated: 2024-06-05

<< < 1 .. 147 148 149 150 151 .. 170 > >> (Page 149 of 170)