Post by mucleus on What is the solution for "Application stopped on recovery switch request"? CODESYS Forge talk (Post)
Hi, everyone. I am using CODESYS RTE and Profinet I/O or EtherCAT I/O. Occasionally (once every 1-2 months) the attached image occurs and the program stops. I want to know why this phenomenon occurs and how to solve it. I attached log. Please help me. Thanks.
Last updated: 2024-07-05

Post by malie on Bibliothek konnte nicht aufgelöst werden CODESYS Forge talk (Post)
Das Problem hab ich gefunden, CoDeSys konnte nicht mehr auf die Netzlaufwerke mit den Bibliotheken zugreifen. Jeder Benutzer ausserhalb von CoDeSys konnte darauf zugreifen. Behebung: 1. CoDeSys schließen. 2. Windows Explorer Netzlaufwerk trennen. 3. Windows Explorer Netzlaufwerk verbinden. 4. CoDeSys öffnen. 5. Bibliotheken werden wieder aufgelöst. Warum da keine anständige Fehlermeldung erscheint?
Last updated: 2024-07-21

Post by ricola on codesys sp20 opcua not working CODESYS Forge talk (Post)
Hi, same pb for me ! did you find a solution ? (I'm working on 2 raspberry pi ) The same project compiled for 4.8.0.0 runtime with CodeSys 3.5SP20 is working fine on one target, and on the other one, my UAexpert receives the same "BadIdentityTokenInvalid" and none is working on 4.11.0.0 either ... anybody ?
Last updated: 2024-08-11

Post by micik on SysFileOpen not working CODESYS Forge talk (Post)
Hi, I have the same problem. Some of the libraries I created over time depend on writing files to a folders like c:\Temp. I can confirm that proposed solution is not working with 3.5.20 Patch 2. Can you please specify wich exactly .cfg file needs to be modified and in what way, in order to include c:\Temp in the SysFile path? Thank you!
Last updated: 2024-08-17

Post by tk096 on gear over gear (2 masters,1 slave) - how to do it? CODESYS Forge talk (Post)
Hi, you could calculate the position/dynamics of the slave axis yourself and use one of the function blocks SMC_FollowPosition/SMC_FollowSetValues to move the slave axis. https://content.helpme-codesys.com/en/libs/SM3_Basic/Current/SM3_Basic/POUs/Movement/Direct/SMC_FollowPosition.html https://content.helpme-codesys.com/en/libs/SM3_Basic/Current/SM3_Basic/POUs/Movement/Direct/SMC_FollowSetValues.html
Last updated: 2024-08-19

Post by anoori on Setting up Raspberry pi as an Opc ua Server with UaExpert as Client CODESYS Forge talk (Post)
I am trying to set up my Raspberry Pi as an OPC UA server and use UaExpert on my Pc as the OPC UA client.However, Im encountering some certificate-related errors in UaExpert: 1.Unable to get local issuer certificate. 2. Unable to get certificate CRL. 3. Unable to verify the first certificate.
Last updated: 2024-09-11

Post by anoori on setting up Raspberry pi as an opc ua Server with UaExpert as Client CODESYS Forge talk (Post)
I am trying to set up my Raspberry Pi as an OPC UA server and use UaExpert on my Pc as the OPC UA client.However, Im encountering some certificate-related errors in UaExpert: 1.Unable to get local issuer certificate. 2. Unable to get certificate CRL. 3. Unable to verify the first certificate.
Last updated: 2024-09-11

Post by eschwellinger on Gateway CODESYS Forge talk (Post)
yes, sorry this is an accident in current Gateway Version. Either use 3.5.20.0 Version. (download from CODESYS Store standalone setup - https://store.codesys.com/en/codesys-edge-gateway-for-windows.html ) or do it manually by: 1. stop Gateway: 2. Add in c:\Windows\System32\config\systemprofile\AppData\Roaming\CODESYS\CODESYSGatewayV3\xxxxxxxx\Gateway.cfg [CmpEdgeGateway] MaintenanceMode=1 3. start Gateway again 4. add it to your CAS Instance
Last updated: 2024-09-18

Post by mg0815 on CoDeSys bricht beim einloggen mit Fehlermeldung ab CODESYS Forge talk (Post)
Ich hatte gestern (WIRD WOHL ZUFALL SEIN) das selbe Problem ... und heute auch noch Codesys 2.3.9.55 2 verschiedene PC's (win10, win7), der ältere hatte IMMER funktioniert. 3 Controller (2x 891, 881) ... und alle mit dem selben Problem Vielleicht antwortest Du hier mal. Tausend Dank PS: Inzwischen auch mit WAGO in Kontakt (aber noch ohne Lösung)
Last updated: 2024-10-02

Post by jwhaley on C0007 Errors CODESYS Forge talk (Post)
Hi all. I'm pretty new to codesys. Maybe a few months. I've had on and off issues here and there. This issue I cant figure out. The top line is one of 2 that I had. The other one has mysteriously left. the 2nd and 3rd showed up after I restarted the program. I'm not sure how to take care of them. Please help!
Last updated: 2024-10-03

Post by yannickasselin on MQTT QoS 1 & 2 CODESYS Forge talk (Post)
Hello, I am using Codesys sp20p3 and IIoT library 1.11. I am trying to test QoS 1 & 2 and I have some issues. I am using mosquitto as the broker. I am also using some other MQTT clients like Node-Red and TwinCAT. They all work as expected for every QoS levels. I only have issues with Codesys MQTT client. In the Codesys client, if I subscribe to a topic as QoS 1 or 2, and a client publishes to this topic, I receive the message. But if I disconnect the Codesys client from the network and a client publishes to the subscribed topic, when I reconnect Codesys client to the network, I don't receive the messages as expected. Also there does not seem to be an auto-reconnect feature. So I have to manually set the mqttClient.xEnable bit to FALSE then back to TRUE in order to reconnect to the broker, then I also have to set the subscribe.xEnable to FALSE and back to TRUE in order to re-subscribe to the topic, but even then, I don't receive the messages that were published while I was disconnected. What am I doing wrong? I set the cleanSession bit to FALSE and I give my client a clientID. With the TwinCAT MQTT Client, I do the same thing and everything works as expected. It even auto-reconnects to the broker. I would expect Codesys MQTT Client to be as reliable as TwinCAT. Maybe I am doing something wrong? I also noticed that when trying to publish a QoS 1 or 2 message while disconnected from the broker, it does not work. In TwinCAT, I am still able to publish. The messages are stored in the client and published once reconnected to the broker. I would expect to be able to do the same thing in Codesys. Is this all possible? Am I doing something wrong? Thank you
Last updated: 2024-10-26

Post by reinier-geers on Energie price CODESYS Forge talk (Post)
On a website i can get the energie price. But how does that work in codesys? There is a video of Rest client. But i can find the HTTP library. If i type on my browser : https://enever.nl/api/stroomprijs_vandaag.php?token=ANWB i get {"status":"true","data":"Please provide a valid API token. More information at https:\/\/enever.nl\/prijzenfeeds\/","code":"2"}
Last updated: 2024-12-03

Post by reinier-geers on Energie price CODESYS Forge talk (Post)
On a website i can get the energie price. But how does that work in codesys? There is a video of Rest client. But i can find the HTTP library. If i type on my browser : https://enever.nl/api/stroomprijs_vandaag.php?token=ANWB i get {"status":"true","data":"Please provide a valid API token. More information at https:\/\/enever.nl\/prijzenfeeds\/","code":"2"}
Last updated: 2024-12-03

Post by csu-chris on Colors look different when logged in and running CODESYS Forge talk (Post)
I am running CODESYS V3.5 SP19 Patch 2 (64-bit) I have buttons that are supposed to be either red or green depending on status. When I am logged out the colors look right. When I am logged in and running the colors are completely different and I can't understand why.
Last updated: 2024-12-06

Post by ph0010421 on How to create a stopwatch? CODESYS Forge talk (Post)
Do you need an 'hours-run' counter? And 1 second resolution is ok? I think you're over-thinking it. (The task time needs to be < 1second) Have a look at the LAD... Then, the time in seconds can be made into hh:mm:ss with this FUNction Declarations: FUNCTION funSecondsToStringTime: string VAR_INPUT InSeconds: UDINT; END_VAR VAR AsString: STRING; Minutes: UDINT; Hours: UDINT; Seconds: UDINT; MinutesAsString: STRING(2); HoursAsString: STRING(2); SecondsAsString: STRING(2); END_VAR and the code: Hours := InSeconds / 60 / 60; //Derive hours Minutes := (InSeconds - (Hours * 60 * 60)) / 60; //Derive minutes Seconds := InSeconds - ((Hours * 60 * 60) + (Minutes * 60));//Derive seconds HoursAsString := UDINT_TO_STRING(Hours); MinutesAsString := UDINT_TO_STRING(Minutes); SecondsAsString := UDINT_TO_STRING(Seconds); IF LEN(HoursAsString) = 1 THEN HoursAsString := CONCAT('0',HoursAsString); END_IF; IF LEN(MinutesAsString) = 1 THEN MinutesAsString := CONCAT('0',MinutesAsString); END_IF; IF LEN(SecondsAsString) = 1 THEN SecondsAsString := CONCAT('0',SecondsAsString); END_IF; AsString := CONCAT(HoursAsString, ':'); //assemble string AsString := CONCAT(AsString,MinutesAsString); AsString := CONCAT(AsString,':'); AsString := CONCAT(AsString, SecondsAsString); funSecondsToStringTime := AsString;
Last updated: 2023-12-08

Post by acc00 on Main Task cycle too long leading to PLC Fail CODESYS Forge talk (Post)
I have 2 Wago PFC200 PLC, running with Runtime SP19 Patch 5, with the Redundant application. The PLC communicates as Modbus Master with at this moment 15 Modbus Slaves -later there will be 28 in total- (Drives, Power management units,...). These devices are connected in 2 rings (1 ring of Drives, 1 ring of Power Management units), with 2 Managed Moxa Switches being part of the ring. Each PLC is connected to one of these switches. The issue I'm encountering is that the Cycle time of the Active PLC goes very high when I'm closing the Drive ring (simulating an issue on one Cabinet supply, resulting in that one Drive shut down, which can happen on field quite often). As a result of this long cycle, the PLC fails and goes to Exception, and the Passive PLC does not take control of the system. A normal cycle is around 30ms for the Main task, and a few ms for the Ethercat task. When I monitor with Profiler, I see that in this Maximum Cycle, the main Task is only taking 13ms, so I'm not sure where the PLC is hanging for so long. Is the remaining cycle time the Redundant management/sync or something else? Thank you in advance.
Last updated: 2024-03-08

Post by faceplant on Comparison via CLI is broken CODESYS Forge talk (Post)
Hello! I am trying to compare 2 projects via the --compare CLI option. In the docs for the --compare option, it describes the usage as .\CODESYS.exe --compare "project path 1" "project path 2". I store my projects in WSL2 on my windows machine. Since CODESYS is happy to open those projects via a path like \\wsl.localhost\home\project.project. So, to compare, I use the command .\CODESYS.exe --compare "\\wsl.localhost\home\prog1.project" "\\wsl.localhost\home\prog2.project". This results in CODESYS just opening the project and starting, not comparing the two projects. No errors are thrown, and I know the paths are correct since I can open both independently in CODESYS, and I can compare them manually through the CODESYS UI. I have also tried moving my projects to the Windows 11 OS and still have the same issue. CODESYS opens the project and does not actually compare them. I am using CODESYS profile v3.5 sp20 patch 1. What is the correct way to compare 2 projects using the --compare CLI option?
Last updated: 2024-12-18

Post by mondinmr on Frustration-Fueled Feedback on Project File Management and Git Integration CODESYS Forge talk (Post)
Good day, I’m writing this message out of frustration regarding the current way project files are saved as encrypted XML and single-file format in CODESYS. I find this approach to be quite tedious for several reasons: Limited Access to Structured Text: Not being able to access Structured Text (ST) externally makes it impossible to work with alternative editors like VSCode. Tools like VSCode are incredibly responsive and feature advanced systems such as GitHub Copilot, which would be a real game-changer when working with ST IEC. While CODESYS works well for small code snippets or debugging, when the codebase grows, switching to VSCode to boost productivity becomes essential, and copy-pasting between environments is a cumbersome workaround. Poor Integration with Git: This file format also makes it very difficult to integrate effectively with Git. I have tested the internal demo, but for advanced merges, it is unusable. Without properly formatted plain text, it’s impossible to leverage the vast ecosystem of external tools around Git that allow smooth merges in heterogeneous teams. File Corruption on Network Drives: I often work from multiple locations with shared network drives. When the development environment saves a file and something goes wrong midway (which can occasionally happen when using VPNs and network drives), the entire project becomes irrecoverable. There’s no way to cancel the save process, and the development environment freezes. This has happened to me at least four times over the past two weeks, and one of those incidents cost me an entire day of work. All of this is particularly disappointing because I truly believe that the libraries, runtime, and overall work done by CODESYS are exceptional. I find it fantastic that there is a platform allowing development of PLCs and control systems using OOP, which is a huge advantage in modern control engineering. I apologize for the rant, but this issue has been extremely frustrating. Best regards.
Last updated: 2024-10-15

Post by acc00 on Redundancy Codesys Runtime, Synchronization CODESYS Forge talk (Post)
Hi, I’m currently testing the Codesys Redundancy application with 2 Raspberry Pi, with the idea is of using in my project 2 Wago PFC200 and 1 Ethercat Master with 2 Remote IO. After I configure the redundancy, and one Pi is Active and the other is Passive, if I disconnect the Ethernet cable of the Active, the Passive become Standalone, which is good, but the problem is the following: -When I recover the Ethernet connection, both stay Standalone. They will NOT Sync until I do it manually in the Codesys environment. How to make the synchronization automatically? -If both Pi/PLC stays Standalone, who is managing the IO? (Ethercat and Serial) I have done a test with an Modbus Slave, where I am sending a counter that increase every second. And I see that when both PLC are standalone, they both keep an active connection with the Slave, and both write values. This does not seem good, since according to this in my project both PLC would try to control the IO at the same time. Note: The Codesys have an option (greyed out, not possible to select) which says “Auto Sync”. What is the purpose, and why I’m not able to select it? I'm using Codesys Control for Rapsberry Pi 64SL Runtime in my test environment (2xRaspberry Pi 4), with the idea of using Codesys Control PFC 200 Runtime in my project (2xWago PFC200 and 1 Ethercat Master with 2x Wago 750-354 Ethercat Fieldbus Coupler). Using the last Codesys 3.5 version (SP19 PAtch 5). I'd appreciate a lot any help on this questions!
Last updated: 2024-01-22

Post by micik on Using Codesys example problems CODESYS Forge talk (Post)
Hello to all, I'm totally new to Codesys, but I do have some PLC programming experience, mosty with Siemens TIA and STEP7. I have just installed Codesys 3.5. sp19 and I have downloaded example with Ethernet Rockwell 1734AENT. The example can be found here: https://forge.codesys.com/prj/codesys-example/rockwell-1734-c/home/Home/ After opening, I had to manually update devices (Device, Ethernet, IP Scanner, EthernetIP adapter). However, when trying to build the project, I get the following errors: [WARNING] CODESYS_EtherNetIP_Rockwell1734AENT: Library Manager [Device: PLC Logic: Application]: C0100: Library System_VisuElemXYChart has not been added to the Library Manager, or no valid license could be found [WARNING] CODESYS_EtherNetIP_Rockwell1734AENT: Library Manager [Device: PLC Logic: Application]: C0100: Library system_visuinputs has not been added to the Library Manager, or no valid license could be found [ERROR] iodrvethernetip, 4.4.1.0 (3s - smart software solutions gmbh): ServiceCycle [IoDrvEtherNetIP]: C0040: Function 'ProcessUpdateConfigurationQueue' requires exactly '1' inputs [ERROR] iodrvethernetip, 4.4.1.0 (3s - smart software solutions gmbh): IoDrvStartBusCycle [IoDrvEtherNetIP]: C0040: Function 'GenerateRandomUINT' requires exactly '2' inputs [ERROR] iodrvethernetip, 4.4.1.0 (3s - smart software solutions gmbh): Cyclic [GenericServiceUnConnected]: C0040: Function 'GenerateRandomUINT' requires exactly '2' inputs [ERROR] cip object, 4.4.1.0 (3s - smart software solutions gmbh): ForwardOpenService [ConnectionManager]: C0040: Function 'GetAssemblies' requires exactly '3' inputs [ERROR] iodrvethernetipadapter, 4.4.0.0 (3s - smart software solutions gmbh): ServiceCycle [IoDrvEtherNetIPAdapter]: C0040: Function 'GenerateRandomUINT' requires exactly '2' inputs [ERROR] iodrvethernetip, 4.4.1.0 (3s - smart software solutions gmbh): SetupStructuredIOMapping [RemoteAdapter]: C0040: Function 'MallocData' requires exactly '1' inputs [ERROR] iodrvethernetip, 4.4.1.0 (3s - smart software solutions gmbh): SetupStructuredIOMapping [RemoteAdapter]: C0040: Function 'MallocData' requires exactly '1' inputs Compile complete -- 7 errors, 13 warnings Build complete -- 7 errors, 13 warnings : no download possible! What could be the reason for this errors and how to rectify them? Thank you!
Last updated: 2024-02-01

Post by thysonfury on OPTO22 Groov Epic PR2 Modbus Comms Dropping out every 2 hours and 4 Mins CODESYS Forge talk (Post)
Hi after some assistance with an error on a Groov PR2 PLC. We have a few different communications set up as shown below: One Modbus TCP Slave Connection - ( Sending / Receiving Data from a PC ) Two Modbus TCP Master Connection - ( Reading Data from a UPS Panel and Reading Data Gas Chromatograph) One Modbus RTU Slave Connection 485 - (Reading Data from a fire and gas panel) One Modbus RTU Master Connection 485 - (Sending Data to a Telemetry Unit) All Licenses have been installed as per OPTO22 suggestions of the order below: Modbus TCP Master Modbus TCP Slave Modbus RTU Master Modbus RTU Slave When I check on License manager the RTU Master license seems to disappear on installing the RTU. (What ever reason I’ve been told this is “normal”). If I use Device License Read It will successfully read all the licenses correctly. Now the issue is every 2 hours and between 4. For what ever reason the communications seems to end and lock up for about 20 seconds. During this time even if I was logged into the PLC it would kick me off and I’d have to re type the password to enter. Most of the devices can handle this however the RTU flags up a communications failure at the SCADA and is raising alarms every 2 hours and 4 mins. We’ve had multiple people go through the code to check for anything obvious. Does anyone have any ideas?
Last updated: 2024-04-15

Post by thysonfury on OPTO22 Groov Epic PR2 Modbus Comms Dropping out every 2 hours and 4 Mins CODESYS Forge talk (Post)
Hi after some assistance with an error on a Groov PR2 PLC. We have a few different communications set up as shown below: One Modbus TCP Slave Connection - ( Sending / Receiving Data from a PC ) Two Modbus TCP Master Connection - ( Reading Data from a UPS Panel and Reading Data Gas Chromatograph) One Modbus RTU Slave Connection 485 - (Reading Data from a fire and gas panel) One Modbus RTU Master Connection 485 - (Sending Data to a Telemetry Unit) All Licenses have been installed as per OPTO22 suggestions of the order below: Modbus TCP Master Modbus TCP Slave Modbus RTU Master Modbus RTU Slave When I check on License manager the RTU Master license seems to disappear on installing the RTU. (What ever reason I’ve been told this is “normal”). If I use Device License Read It will successfully read all the licenses correctly. Now the issue is every 2 hours and between 4. For what ever reason the communications seems to end and lock up for about 20 seconds. During this time even if I was logged into the PLC it would kick me off and I’d have to re type the password to enter. Most of the devices can handle this however the RTU flags up a communications failure at the SCADA and is raising alarms every 2 hours and 4 mins. We’ve had multiple people go through the code to check for anything obvious. Does anyone have any ideas?
Last updated: 2024-04-15

Post by thysonfury on OPTO22 Groov Epic PR2 Modbus Comms Dropping out every 2 hours and 4 Mins CODESYS Forge talk (Post)
Hi after some assistance with an error on a Groov PR2 PLC. We have a few different communications set up as shown below: One Modbus TCP Slave Connection - ( Sending / Receiving Data from a PC ) Two Modbus TCP Master Connection - ( Reading Data from a UPS Panel and Reading Data Gas Chromatograph) One Modbus RTU Slave Connection 485 - (Reading Data from a fire and gas panel) One Modbus RTU Master Connection 485 - (Sending Data to a Telemetry Unit) All Licenses have been installed as per OPTO22 suggestions of the order below: Modbus TCP Master Modbus TCP Slave Modbus RTU Master Modbus RTU Slave When I check on License manager the RTU Master license seems to disappear on installing the RTU. (What ever reason I’ve been told this is “normal”). If I use Device License Read It will successfully read all the licenses correctly. Now the issue is every 2 hours and between 4. For what ever reason the communications seems to end and lock up for about 20 seconds. During this time even if I was logged into the PLC it would kick me off and I’d have to re type the password to enter. Most of the devices can handle this however the RTU flags up a communications failure at the SCADA and is raising alarms every 2 hours and 4 mins. We’ve had multiple people go through the code to check for anything obvious. Does anyone have any ideas?
Last updated: 2024-04-15

Post by rossanoparis on After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working CODESYS Forge talk (Post)
For those who will step on this thread. Everything is fine, I had only to increase by 1 my place holders number. For sure the system is occupying the number 1 without being declared ... Below the modification I made to get my code working. [SysFile] PlaceholderFilePath.2=/home/pi/hpca/bin, $hpcabin$ PlaceholderFilePath.3=/home/pi/hpca/cfg, $hpcacfg$ PlaceholderFilePath.4=/home/pi/hpca/logs, $hpcalogs$ PlaceholderFilePath.5=/home/pi/hpca/resources, $hpcares$
Last updated: 2023-08-22

Post by timvh on When Keyboard Key is in Hold, then Webvisu is extreme slow and latent CODESYS Forge talk (Post)
I'm not really sure what you are trying to do, but maybe you are referring to using the CmpCharDevice library? When you "open" the connection to a device, you can pass flags. What helped me is to set the non-blocking flag. I'm not sure if this is what you are referring to, but maybe it helps: dFlags: DINT := CmpCharDevice.ACCESS_MODE.O_RDONLY + DINT#4000; // see details for flags: http://linux.die.net/man/2/open, + DINT#4000 is for non-blocking hDevice := CmpCharDevice.CDOpen(szFilename, dFlags, Result);
Last updated: 2023-09-20